DIGITAL INPUT MODULE
6ES73261BK020AB0
DIGITAL INPUT MODULE
SIMATIC S7
SM 326
F-DI 24X 24 VDC
FAIL-SAFE DIGITAL INPUT FOR SIMATIC S7 F-SYSTEMS
WITH DIAGNOSTIC ALARM
COMMUNICATION PROCESSOR
COMMUNICATION PROCESSOR
CP 1613 A2 PCI CARD
(32BIT;33MHZ/66MHZ; 3.3V/5V UNIVERSAL KEY)
FORCONNECTION TO IND
ETHERNET (10/100MBIT/S)
WITH ITP ANDRJ 45 PORT VIA
HARDNET-IE S7 AND S7-REDCONNECT
SUPPORT FOR OPERATING SYSTEM
Analog Input Module
MODULE
SIMATIC S7-200 SMART
ANALOG INPUT AI04
SUPPLY 24VDC
AI 4X12
BIT +/-10VDC/0-20MA
CPU 315-2DP Processor Module
CENTRAL PROCESSING UNIT
SIMATIC S7-300
315-2 DP
0.9 AMP
24 VDC
64KB MEMORY
2ND INTERFACE DP MASTER/SLAVE
Inverter Control Module
Inverter control Module IGD8
for devices 500-690V 3 AC
50/60 Hz and 675-930V DC
860 A and 1580 A
Single Motor Module
SINAMICS S120
Single Motor Module
input: 600 V DC
output: 400 V 3 AC, 30 A
type of construction: booksize internal
air cooling optimized pulse patterns
and support of the extended
Safety Integrated functions
incl. DRIVE-CLiQ cable
DRIVER BOARD
Compatible Series:MICROMASTER 430 / 440
Voltage Class:400 V / 480 V
Power Rating Supported:7.5 kW – 55 kW
Control Voltage:15 – 24 VDC
Operating Temperature:0°C to +50°C
Storage Temperature:-25°C to +70°C
SITOP Redundancy Module
SITOP PSE202U
Redundancy M
DC24V/40A
SITOP PSE202U
redundancy module
input/output: 24 V DC/40 A
suitable fordecoupling two
SITOP power supplies with
maximal per 20 A output current

Copyright Notice © 2004-2024 amikong.com All rights reserved
Disclaimer: We are not an authorized distributor or distributor of the product manufacturer of this website, The product may have older date codes or be an older series than that available direct from the factory or authorized dealers. Because our company is not an authorized distributor of this product, the Original Manufacturer’s warranty does not apply.While many DCS PLC products will have firmware already installed, Our company makes no representation as to whether a DSC PLC product will or will not have firmware and, if it does have firmware, whether the firmware is the revision level that you need for your application. Our company also makes no representations as to your ability or right to download or otherwise obtain firmware for the product from our company, its distributors, or any other source. Our company also makes no representations as to your right to install any such firmware on the product. Our company will not obtain or supply firmware on your behalf. It is your obligation to comply with the terms of any End-User License Agreement or similar document related to obtaining or installing firmware.