Current Monitor Board
Power Supply: 24V DC
Type: Current Monitor Board
Operating Temperature: Ranges from 0°C to 60°C
Communication Interface: RS-232, RS-485, or similar
Control Card
Catalog Description:
V PP C905 AE101; CCB-2 COMPLETE
Long Description:
V PP C905 AE101
Rigi Crowbar Drive PCB
Power Supply:24V
Operating Temperature Range
Typically -20°C to +60°C
Storage Temperature Range
-40°C to +85°C
CVMI Board
Voltage Input Range:24 VDC or 110/220 VAC
Current Input: 1-10 A
Power Supply: 24 VDC or 48 VDC
Operating Temperature Range: -20°C to +60°C
Storage Temperature Range: -40°C to +85°C
HVD Board
Power Supply: 24 V DC
Communication Protocol:
Ethernet, Modbus TCP/IP
Operating Temperature Range:
-20°C to +60°C
Control module
Power Supply: Typically 24 V DC (±20%)
Power Consumption: Around 10 W
Operating Temperature Range: -20°C to +60°C
Storage Temperature Range: -40°C to +85°C
Humidity: 5% to 95% (non-condensing)
Protocols Supported: CAN, Modbus
PP D113 B01-25-111000: AC 800PEC
Long Description:Containing:
Slot ANYIO-1 (U4) CEX2-Bus RS422
Slot ANYIO-2 (U5) Anybus/Modbus TCP
Slot Opt. Mod.1 (U7) UF D128
Slot Opt. Mod.2 (U8) UF D128
Slot Opt. Mod.3 (U9) UF D128
Slot Opt. Mod.4 (U10) empty
Slot Opt. Mod.5 (U11) empty
CONTROL BOARD
4 channels (0-20mA, 4-20mA)
8 channels
RS-485, Ethernet, Modbus
24V DC
-20°C to +60°C
Control Module
Part Number: UNS0118A-Z
Type: Control Module
Voltage: 24V DC
Operating Temperature: Typically -20°C to +60°C
Storage Temperature: -40°C to +85°C
IGCT Module
Blocking Voltage 4500 V DC
Reverse Voltage:30 V
Max RMS Current:4000 A
Peak Surge Current :32 kA
Turn-On Time: ≤ 3 µs
Turn-Off Time: ≤ 5 µs
Switching Loss: ≤ 15 kJ/s at 500 Hz
Communication Module
Order Code:3BHE019958R0101
Functional Designation:UA D206 A
Power Supply:5 V DC
Consumption: 500 mA (max)
Data Rate:300 bps – 115.2 kbps (per port)
Isolation:500 V AC
Interface Module
Signal Channels:16 single-ended analog inputs
Voltage: ±10V, ±5V, ±1V, 0–10V
Current: 4–20mA, 0–20mA
Resolution:16-bit (including sign bit)
Accuracy:±0.05% of full scale (25°C)
Sampling Rate:10 ms/channel
Input Impedance:>1 MΩ
Overvoltage Protection:±30V continuous
Common-Mode Rejection:>120 dB at 50/60 Hz