Kindly Reminder
Can't Find Your Required Components?
If your specific control system parts are not listed on our website, contact us immediately.
Our procurement specialists will source genuine new components tailored to your technical requirements.
All Amikon-supplied automation parts include:
12 Months Warranty
24h /7 online Service ( info@amikon.cn | +86 18020776786 )
Original new Factory Sealed
PANEL INTERFACE
64532588
Interface Board
ADPI-01 PANEL INTERFACE
Power Supply:24V DC
Consumption: 15W (typical)
Operating Voltage:18–30V DC (±10%)
Isolation :500V AC between ports and power
Control board
Processor:Dual-core CPU
Memory:512 MB RAM
Flash Storage:1 GB internal
Power Supply:24 V DC
Communication Ports
2x Ethernet (RJ45): 10/100/1000 Mbps
1x Serial (RS-232/485): For legacy devices (MODBUS RTU).
1x USB 2.0: For engineering access.
POWER SUPPLY BOARD
POWER SUPPLY BOARD
WITH JUMPER WIRE
Primary Input: 18–32 V DC
Backup Input: 24 V DC
Output Voltage: 24 V DC
Output Current: 6 A
Holdup Time: ≥48 hours
Efficiency: >85% (typical).
Ripple & Noise: <100 mV peak-to-peak
PLC BOARD
Power Supply:24V DC (±10%)
Power Consumption:≤ 5W
Isolation:1500V AC
Digital: 16–32 channels
Analog: 4–8 ch
USB-Hardlock Key for ECT
USB-Hardlock Key for ECT with 1 licence
Encryption:AES-128/256-bit
Hardware ID:Unique 64-bit serial number
Operating Voltage:5V DC
Power Consumption:≤ 100 mA
PCB Board
Fiber Optic Ports: 6–12 channels
Power supply pins:+24V DC, +5V DC
Operating Voltage: 24V DC
Power Consumption: ≤ 15W
Reinforced isolation:2.5kV
Drive Digital Processor Module
Power Supply Voltage:24 VDC
Power Consumption:< 5 Watts
Operating Temperature:-10°C to +55°C (14°F to 131°F)
Storage Temperature:-40°C to +70°C (-40°F to 158°F)
Humidity:5% to 95% non-condensing
Compact module
Compact installation of I/O modules
Up to 16 channels of field signals
and process power connections
Connections to ModuleBus and I/O modules
Mechanical keying prevents
insertion of the wrong I/O module
Latching device to DIN rail for grounding
DIN rail mounting
IGCT Module
Voltage Class:6.5kV AC/DC
Continuous Anode Current:5,150 A RMS
Surge Current (10ms pulse):45 kA peak
Switching Speed:Turn-off <4.5 μs
Gate Drive:-18V ~ +22V w/±200A
Storage temp. Limit:-40℃ to +100℃
Starter kit
CPU:16-bit Renesas RX630 MCU
Memory:256KB RAM
Communication:2 × Ethernet (10/100BASE-T)
I/O Simulation:Virtual D/I and D/O
Power Supply:24V DC
6 × D/O (Transistor Sink: 0.5A @ 24V DC
Power cables :24V DC
IGCT controller module
Reverse Voltage:4500V+
Forward Current:250–5000A
Switching Speed:<100 μC
Trigger Voltage/Current:+15/-15V pulses
Turn-On/Off Time:300–500 ns
Fieldbus Communication Interface
CI810B AF100 Fieldbus Communication Interface
2*AF100 Twisted Pair Modems.
Including:
1 pce Power Supply Connector 3BSC840098R1
1 pce TB807 Modulebus Terminator 3BSE008538R1
2 pcs Terminal Blocks 3BSC840098R1
The basic system software version 1.5 loaded.
AF100 Connector 3BSC840105R1
Processor module
AC500-eCo Processor module
Memory 4MB
12 DI 24 VDC. 6 DO-Relay
2 DC 24 VDC
Ethernet interface
3 option slots
Controller Module
Clock Speed: 800 MHz – 1.5 GHz
RAM: 2 GB DDR4
Operating Voltage: 24 V DC
Power Consumption: ≤18 W
Isolation: ≥3000 V AC
Ethernet Interfaces:2× Gigabit ports
Discrete I/O: 12–24 V DC
Analog Interfaces: 4–8 channels
Motherboard
Input Voltage: 24 V DC
Backplane Power: 5 V DC
RAM Slots: 2× DDR4 SO-DIMM
Storage: Integrated 16 GB flash
Operating: -40°C to +70°C
Humidity: 5–95% non-condensing
MTBF: >250,000 hours
Processor Module
Operating Voltage: 24 V DC
Power Consumption: <12 W
Input Protection:±40 V peak transient
Digital I/O: 16 channels
Analog I/O (Optional): 4 channels
Ethernet: 2× 10/100 Mbps ports
Serial: RS-232/RS-485 for legacy devices
Fieldbus: PROFIBUS DP
Control Board
Operating Voltage: 24 V DC
Power Consumption: ≤15 W
Voltage Range: 0–10 V DC
Resolution: 12-bit
Channels: ≥8 opto-isolated
Input Signal Level: 24 V DC
Analog input module
Function:4 AI: U, I
Number of Analog Configurable I/Os:0
Analog Inputs:4
Input Signal:U, I
Resolution:Analog Input 12 bit
Connection Type:Pluggable
Degree of Protection:Housing IP20
Ambient Air Temperature:
Operation 0 ... +60 °C
Storage -40 ... +70 °C
Interface board
Power Supply: 24 VDC (±10%) or 110–240 VAC
1–2 x RJ45 Ethernet ports.
Serial ports (RS-232/485) for legacy devices
Fiber-optic or coaxial connectors
Operating Temperature: -20°C to +60°C
Humidity: 5–95% non-condensing
ANALOG MODULE
Analog Inputs: 8–16 channels
Voltage Ranges: ±10V, 0–10V, 1–5V
Current Ranges: 4–20 mA, 0–20 mA
Analog Outputs: 4–8 channels
Voltage: 0–10V, ±10V
Current: 4–20 mA
Resolution:16-bit ADC/DAC
Power supply
Input Voltage AC Input: 100–240V AC (±10%), 50/60 Hz
Current: 10A
Efficiency: ≥85% (typical)
Operating Temperature: -25°C to +70°C (-13°F to +158°F).
Storage Temperature: -40°C to +85°C (-40°F to +185°F).
Certifications: CE, UL, IEC 61131-2, RoHS
Control Board
Operating Voltage: Typically 24 V DC
Input Voltage: 380-460 VAC
Output Voltage: 0-460 VAC
Output Frequency: 0-60 Hz
Output Power: 1.5 kW
Efficiency: Up to 98%

Copyright Notice © 2004-2024 amikong.com All rights reserved
Disclaimer: We are not an authorized distributor or distributor of the product manufacturer of this website, The product may have older date codes or be an older series than that available direct from the factory or authorized dealers. Because our company is not an authorized distributor of this product, the Original Manufacturer’s warranty does not apply.While many DCS PLC products will have firmware already installed, Our company makes no representation as to whether a DSC PLC product will or will not have firmware and, if it does have firmware, whether the firmware is the revision level that you need for your application. Our company also makes no representations as to your ability or right to download or otherwise obtain firmware for the product from our company, its distributors, or any other source. Our company also makes no representations as to your right to install any such firmware on the product. Our company will not obtain or supply firmware on your behalf. It is your obligation to comply with the terms of any End-User License Agreement or similar document related to obtaining or installing firmware.