ABB are a market leading producer of power & automation technologies that enhance performance and reduce environmental impact for industries worldwide.
Amikon Limited stock and supply ABB motors, drives, programmable logic controllers (PLCs), power electronics and Robot spare parts and Discontinued card parts, motion and obsolete including variable speed drives, DC drives, PLCs and general automation spares.
ABB are a market leading producer of power & automation technologies that enhance performance and reduce environmental impact for industries worldwide.
Amikon Limited stock and supply ABB motors, drives, programmable logic controllers (PLCs), power electronics and Robot spare parts and Discontinued card parts, motion and obsolete including variable speed drives, DC drives, PLCs and general automation spares.
Safety Category:Category 3 (EN 954-1)
Response Time:≤ 20 ms
Supply Voltage:24 V DC ±10%
Power Consumption:≤ 2 W
Input Signal:24 V DC (Pulse test: 0.5 Hz, 1 ms)
Input Current:6 mA per channel
IsolationReinforced isolation : 500 V AC
Blocking Voltage 4500 V DC
Reverse Voltage:30 V
Max RMS Current:4000 A
Peak Surge Current :32 kA
Turn-On Time: ≤ 3 µs
Turn-Off Time: ≤ 5 µs
Switching Loss: ≤ 15 kJ/s at 500 Hz
Rated Voltage:380–480 V AC, 3-phase (±10%)
Rated Current:100 A (at 40°C ambient)
Frequency:50/60 Hz
Leakage Current:< 5 mA (at 480 V AC)
Insulation Resistance:> 100 MΩ (500 V DC)
Dielectric Strength:3000 V AC
3-phase AC: 380–480 V AC
DC Bus Voltage:520–720 V DC
Power Rating:Typically 1–50 kW
Operating Temperature:-10°C to +50°C
Storage Temperature:-40°C to +85°C
Order Code:3BHE019958R0101
Functional Designation:UA D206 A
Power Supply:5 V DC
Consumption: 500 mA (max)
Data Rate:300 bps – 115.2 kbps (per port)
Isolation:500 V AC
Processor: 1.2 GHz
Power Supply: 24V DC ±10%
Power Consumption: 120W
MTBF: >200,000 hours
Control Loop Speed: 0.5–5 ms (configurable)
Max I/O Points: 5,000 digital / 2,000 analog
Function:16 AI: U, I, RTD, DI
Number of Analog Configurable I/Os:0
Analog Inputs:16
Input Signal:U, I, RTD, DI
Resolution:Analog Input 13 bit
Degree of Protection:Housing IP20
Supply Voltage:24 V DC
Ambient Air Temperature:
Operation 0 ... +60 °C
Storage -40 ... +70 °C
Supply Voltage: 24V DC (±10%), 5A max.
Atomization air pressure control
Fluid flow regulation (via PWM or analog valve)
HV electrostatic control (up to 100 kV)
Solvent purge management
Diagnostic monitoring (clogs, pressure faults)
Power Consumption: 120W (peak)
Range: Typically 20.4 V DC
Series: 83SR Safety Relay System
Channel-to-Backplane/Logic: Yes
Isolation Voltage: Typically 250V AC
Safety Certification: TÜV Rheinland certified
Output Current: 105 A
Integrated Filter: L500
Frame Size: R7
Cooling Method: Air cooling
Voltage:3-phase 380–480 V AC (±10%)
Frequency:47–63 Hz
Input Current:120 A
Motor Power Range:55–75 kW
Apparent Power (S1):89 kVA (at 480 V)
Measurement Range:0–50 kN
Accuracy"±0.5% of full scale (typical)
Digital Option:RS-485 Modbus RTU
Excitation Voltage:10–30 V DC
Bridge Resistance:350 Ω ±1%
Cable Length:Standard 10m
Overload Capacity:150% of rated range
Rated Operational Voltage (Ue):230/400V AC (50/60 Hz)
Rated Insulation Voltage (Ui):500V AC
Rated Current (In):Up to 100A
Short-Circuit Capacity (Icn):10 kA
Mounting Depth:10–120 mm
Material:Galvanized steel
System Voltage:24 V DC (19.2–30 V DC)
Power Consumption:≤ 1.5 W (typical)
Communication Protocol:Profibus DP-V1
Modbus RTU (via FCI module)
Isolation:Galvanic isolation between
Input Channels:16
Input Type:Dry Contact or 24V DC Sourcing
Voltage Range:19–30 V DC
Input Current:3–5 mA per channel
Logic Levels:"1" (ON): +15–30 V DC
"0" (OFF): 0–5 V DC
Response Time:≤ 2 ms (ON/OFF)
Overvoltage Protection:60 V DC (continuous), 75 V DC (1s)
Isolation:1500 V AC
Input Voltage :24 V DC (±20%)
or 48 V DC (±20%)
Analog Inputs:6 channels
Digital Inputs:8 channels
Analog Outputs:4 channels
(0–20 mA / 4–20 mA)
Digital Outputs:6 channels
Processing Speed:32-bit DSP
Communication:RS-485 Modbus RTU, CANopen
Input Channels:16x Binary Inputs
Output Channels:10x Binary Outputs
Contact Rating (Outputs):5A @ 250V AC/30V DC
Input Voltage Ranges:24/48/110/125 V DC
Input Threshold (ON):>70% of rated voltage
Response Time:<10 ms
Isolation Voltage:2.5 kV AC
Power Consumption:≤ 5 W
Isolation Voltage:1.5 kV AC
Power Supply:24 V DC (±15%), 5 W typical
Redundancy:Dual fiber ports
Fiber Interface:2x ST/PC connectors
Data Rate:10 Mbps
Max. Distance:2 km
Operating Voltage:24V DC (±10%), 3W typical
Accuracy:±0.5% of full scale
Resolution:0.1% (for bargraph display)
Update Rate:100 ms
Isolation: 1.5 kV AC
MODE Switch: Toggle MAN/AUTO/CAS
Control Platform:32-bit RISC processor with FPGA logic
Control Methods:DTC , Scalar, Vector
I/O Capacity:16x DI
Operating Voltage:24 V DC (±10%)
Power Consumption:25 W (typical)
Memory:2 GB Flash (firmware/logs)
Rated System Voltage:3300V AC (2.3–4.16 kV range)
DC Link Voltage:5600V DC (max)
IGCT Control :24x Gate driver channels
Gate Drive Voltage:+20V / -5V
Auxiliary Power:24V DC (±10%), 150W
Isolation Voltage:6 kV AC
Response Time:<2 µs
Generator Voltage:100–690V AC (50/60 Hz),
Field Voltage (Output):10–250V DC
Regulation Accuracy:±0.5%
Response Time:<30 ms
Auxiliary Supply:24/48/110/250V
Power Consumption:≤25 W (standby)
Input Voltage: Typically 24V DC
Output Signals: Digital and analog signals for
motor control and feedback.
Current Consumption:100-500mA
Communication Voltage Levels: 3.3V or
5V logic levels for digital communication.
DCS880
SDCS-CON-H01
Main Control Board
Operating Voltage:24 V DC (±10%)
Current Consumption:≤1.5 A
Digital I/O Channels:32 optoisolated DC I/O points
Analog I/O:±10 V DC / 4–20 mA