Motion Controller Module
Series:RX3i PacSystem
Part Number:IC695PMM335
Catalog:IC695
No. of Axes:4
No of Master axes:1
Backplane Support:Universal Support
Motion Path Planning:1ms
Number of Slots:1 (single slot)
Position Loop Update Rate:500μs
Controlled Axes/Module:4
FSSB Velocity Loop Update Rate:125μs
Motion Path Planning:1 ms
FSSB Torque Loop Update Rate:62.5μs
Power Consumption at 5 V:0.45 A
Servo Command Interface:Fiber Optic
Power Consumption at 3.3 V:1.1 A
Floating Point:Yes
Redundant fault-tolerant control system
Input Voltage: 24V DC
Current Consumption: 1.5A typical
Isolation: 1500V AC channel-to-channel
Trip Contact Ratings:5A @ 30V DC resistive
Analog Inputs: 8 channels
Relay Outputs: 8 channels
Communication Ports: 2x Ethernet for diagnostics
Resistance Temperature Device
RTD INPUT MODULE
8 CHANNEL
14-BIT
15 OHMS MAX.
2 ETHERNET PORTS
FOR MARK VI TURBINE CONTROL SYSTEM
Thermocouple Input Module
IO PACK
THERMOCOUPLE
2 ETHERNET PORTS
AMBIENT TEMPERATURE RATING:
-30 TO + 65°C (-22 TO +149 °F)
Discrete Contact Input I/O Module
Power Supply:28VDC
Functional Revision 1:A
Mark VI Series Grouping:Group 1
Number of Channels:16 (isolated)
Input Type:Dry contact (volt-free) or wet contact (24–125V DC)
Voltage Range:24–125V DC (configurable)
Input Current :2–20mA per channel
On-State Voltage:≤3V DC (for dry contact)
Off-State Leakage:<1mA
Analog I/O Module
CARD
INPUT/OUTPUT PACK
ANALOG IN/OUT
200 MA TYPE
FOR MARK VIE TURBINE CONTROL SYSTEM
Discrete input module
Series:PACSystem RX3i
Manufacturer:GE Fanuc
Part Number:IC694MDL240
Description:Input module
No of Channels:Sixteen (16)
Points:16
Input signal range:0-132 VAC
Voltage:120 Volts AC
Nominal Input voltage:0-120 VAC
Current:7 milliamps
Input Frequency:47-63 Hz
Power consumption:90 milliamps
Input current:12mA per channel
Input current:12 mA
Bus voltage:5 Volts
Current draw:90 mA (all inputs active)
Off response time, maximum:45 ms
On state current:6 mA
On response time, maximum:30 ms
Product Lifecycle Status:Active
Off state current:2.2 mA
On–state Current:6mA minimum
On response time, typical:30 ms
Power Transducer Module
Series:Series 90-30
Manufacturer:GE Fanuc (Former); Emerson Automation (Current)
Part Number:IC663PTM101
Description:Power Transducer module
Voltage:10-120 Volts AC
Mounting:Any Series 90-30 Baseplate
Current:0-7.5 Amperes
Compatible Series 90-30 CPU:Any CPU module
Dissipation:4 Watts
Frequency:35-70 Hertz
Resolution:14-bit
Total Power Dissipation:4W max
Backplane isolation Voltage:1500 Volts
Product Lifecycle Status:Discontinued/Obsolete
LAN Communications Card
TURBINE CONTROL SYSTEM
MARK V
SPEEDTRONICS
W/FIRMWARE
16 DIGIT DISPLAY
Power Excitation Board
Mark V
DS200RTBAG3AHC
Turbine Control System
Relay Terminal Board

Copyright Notice © 2004-2024 amikong.com All rights reserved
Disclaimer: We are not an authorized distributor or distributor of the product manufacturer of this website, The product may have older date codes or be an older series than that available direct from the factory or authorized dealers. Because our company is not an authorized distributor of this product, the Original Manufacturer’s warranty does not apply.While many DCS PLC products will have firmware already installed, Our company makes no representation as to whether a DSC PLC product will or will not have firmware and, if it does have firmware, whether the firmware is the revision level that you need for your application. Our company also makes no representations as to your ability or right to download or otherwise obtain firmware for the product from our company, its distributors, or any other source. Our company also makes no representations as to your right to install any such firmware on the product. Our company will not obtain or supply firmware on your behalf. It is your obligation to comply with the terms of any End-User License Agreement or similar document related to obtaining or installing firmware.