POWER SUPPLY BOARD
                                                    
                                                    
                                                        
                                                        POWER SUPPLY BOARD
WITH JUMPER WIRE
Primary Input: 18–32 V DC
Backup Input: 24 V DC 
Output Voltage: 24 V DC
Output Current: 6 A
Holdup Time: ≥48 hours 
Efficiency: >85% (typical).
Ripple & Noise: <100 mV peak-to-peak
                                                    
                                                
CONTROL BOARD
                                                    
                                                    
                                                        
                                                        Ethernet (2 ports):10/100 Mbps
Voltage: 24 V DC
Power Consumption: 5-7 W (typical)
I/O Handling:up to 64 I/O channels
BW GasAlert Connectivity Kit
                                                    
                                                    
                                                        
                                                        GA-USB1-IR IR
Connectivity Kit with
Fleet Manager II
Software
                                                    
                                                
IGCT Module
                                                    
                                                    
                                                        
                                                        Turn-off Time: ≤ 8 µs.
dv/dt: 1,000 V/µs (min)
Supply Voltage: +15V
Gate Current: 60 A
Capacitance: 5 µF (±10%)
Voltage: 2,000 V DC 
Thermal Resistance: 0.008 K/W
Mounting Pressure: 12–15 kN 
                                                    
                                                
CIRCUIT BOARD CARD
                                                    
                                                    
                                                        
                                                        I / O BOARD
DIGITAL BUFFER
CARD CAGE
Analog Inputs: 8–16 channels
Digital I/O: 16–32 channels
                                                    
                                                
VOICE FREQUENCY TELEGRAPHY DEVICE
                                                    
                                                    
                                                        
                                                        Carrier Frequencies: 300–3400 Hz 
Channel Spacing: 120 Hz or 240 Hz
Shift Range: ±30 Hz, ±60 Hz, or ±120 Hz 
Baud Rate: 50 Bd or 200 Bd 
Voltage: 48/60 VDC
Power Consumption: <15 W
Operating Threshold: -30 dBm 
Voltage: 48/60 VDC nominal 
Operating Temperature: -20°C to +65°C.
                                                    
                                                
PLC BOARD
                                                    
                                                    
                                                        
                                                        Power Supply:24V DC (±10%)
Power Consumption:≤ 5W
Isolation:1500V AC 
 Digital: 16–32 channels
Analog: 4–8 ch
                                                    
                                                
USB-Hardlock Key for ECT
                                                    
                                                    
                                                        
                                                        USB-Hardlock Key for ECT with 1 licence
Encryption:AES-128/256-bit
Hardware ID:Unique 64-bit serial number 
Operating Voltage:5V DC
Power Consumption:≤ 100 mA
                                                    
                                                
PCB Board
                                                    
                                                    
                                                        
                                                        Fiber Optic Ports: 6–12 channels
Power supply pins:+24V DC, +5V DC
Operating Voltage: 24V DC
Power Consumption: ≤ 15W
Reinforced isolation:2.5kV
                                                    
                                                
CONTROL UNIT
                                                    
                                                    
                                                        
                                                        CPU: 32-bit RISC processor.
Clock Speed: 120 MHz.
Work Memory (RAM): 2 MB
Retentive Memory: 1 MB
Program Memory: 8 MB Flash
                                                    
                                                
Digital Governor Turbine Control
                                                    
                                                    
                                                        
                                                        Input Voltage:+24 Vdc at 1 A
Keypad/Display:30 Key Multi-function Keypad
Operating Temperature:–20 to +60 °C
Outputs:2 Actuator Outputs, 8 Relay Outputs
6 Programmable Current Outputs
Slot Type:Supports RS-232, RS-422, and RS-485 hardware
Software Version:OpView™ and 505View
Storage Temperature:–40 to +85 °C
                                                    
                                                
DIGITAL INPUT PROCESSOR
                                                    
                                                    
                                                        
                                                        DIGITAL INPUT PROCESSOR
MU-PDIS12
REDUNDANCY SUPPORT
32 INPUT CHANNELS
20/30 VDC
90/132 VAC RMS
                                                    
                                                
Earth-fault relay
                                                    
                                                    
                                                        
                                                        Rated Current:1 A or 5 A 
Rated Voltage:48–250 V AC/DC
Burden:< 0.5 VA
Contact Rating:5 A @ 250 V AC
Mounting:Panel-mounted 
Operating Temperature:-25°C to +55°C
                                                    
                                                
Proximity measurement system
                                                    
                                                    
                                                        
                                                        From the vibro-meter® product line
Ex certified versions for use in hazardous areas
TQ401 conforms to API 670 recommendations
5 and 10 m systems
Temperature-compensated design
Frequency response:DC to 20 kHz (−3 dB)
Measurement range:2 mm
Temperature range:−40 to +180 °C
                                                    
                                                
Proximity measurementsystem
                                                    
                                                    
                                                        
                                                        From the vibro-meter® product line
Ex certified versions for use in hazardous areas
TQ401 conforms to API 670 recommendations
5 and 10 m systems
Temperature-compensated design
Frequency response:DC to 20 kHz (−3 dB)
Measurement range:2 mm
Temperature range:−40 to +180 °C
                                                    
                                                
Panel Mount Operator Advisor Panel (OPADP)
                                                    
                                                    
                                                        
                                                        51305776100
INTERFACE MODULE ASSEMBLY
ADAPTER UNIT
OEP/IKB
                                                    
                                                
Digital Input 24V IOTA Redundant
                                                    
                                                    
                                                        
                                                        Galvanic isolation
Open wire detectio
Optional redundancy
Direct / Reverse Input Indication
Supplies Non-incendive field power
Internal or external field power selection
Extensive internal diagnostics for data integrity
                                                    
                                                
HART Analog Output Module
                                                    
                                                    
                                                        
                                                        Input Voltage:100–240 VAC (universal) 
Output Voltage:24 VDC (adjustable up to ~27 V)
Output Current:20 A continuous
Protections:Overcurrent, overvoltage, short-circuit
Operating Temperature Range:–25 °C to +70 °C
                                                    
                                                
Safety Manager System Module
                                                    
                                                    
                                                        
                                                        Supply voltage: 24 V DC
Reset input voltage: 18 - 70 V DC
Reset input current: 1.1 mA at 24 V DC
Earth fault threshold: 5.5 mA (± 1 mA)
Max. earth current: 25 - 32 mA
                                                    
                                                
Electronic Earth Leakage Detector
                                                    
                                                    
                                                        
                                                        Supply voltage: 24 V DC
Reset input voltage: 18 - 70 V DC
Reset input current: 1.1 mA at 24 V DC
Earth fault threshold: 5.5 mA (± 1 mA)
Max. earth current: 25 - 32 mA
Max. output current: 2 A
Isolation 1500 V DC / 1000 V AC
Initial contact resistance: 30 mW
Operating temperature: -5°C-+50°C (23°F-+122°F)
Max. output voltage: 36 V DC / 30 V AC
                                                    
                                                
DESK OPERATOR ENTRY PANEL
                                                    
                                                    
                                                        
                                                        TPDSOEP1100
51402497-200
TDC 3000 
Operator Keyboard
DESK OPERATOR ENTRY PANEL
                                                    
                                                
FTA interconnection cable
                                                    
                                                    
                                                        
                                                        Direct connection between two 
FS-CP series process controllers
20meters long
Shielded twisted pair design
Easy to install and use
Hot-pluggable
                                                    
                                                
Digital input module
                                                    
                                                    
                                                        
                                                        DIGITAL INPUT MODULE 
LINE MONITORED W/ FAULT MONITOR
16 CHANNELS
Functional tests of the various trip levels applied
Channel independence
Monitoring of supply voltage to input devices
Earth connection
Used supply voltages
                                                    
                                                
Digital I/O module
                                                    
                                                    
                                                        
                                                        Channels:Typically 16 I/O 
Output Types:Digital(0–10 VDC, 4–20 mA)
Analog Resolution:AI: 16‑bit; AO: 13‑bit
Power Supply:24 V DC nominal
Power Isolation:Galvanic isolation, reverse protection
Operating Temp:–40 °C to +70 °C
Enclosure / Rating:Up to IP66
                                                    
                                                

 
	
		Copyright Notice © 2004-2024 amikong.com All rights reserved
Disclaimer: We are not an authorized distributor or distributor of the product manufacturer of this website, The product may have older date codes or be an older series than that available direct from the factory or authorized dealers. Because our company is not an authorized distributor of this product, the Original Manufacturer’s warranty does not apply.While many DCS PLC products will have firmware already installed, Our company makes no representation as to whether a DSC PLC product will or will not have firmware and, if it does have firmware, whether the firmware is the revision level that you need for your application. Our company also makes no representations as to your ability or right to download or otherwise obtain firmware for the product from our company, its distributors, or any other source. Our company also makes no representations as to your right to install any such firmware on the product. Our company will not obtain or supply firmware on your behalf. It is your obligation to comply with the terms of any End-User License Agreement or similar document related to obtaining or installing firmware.