Input Voltage: 24 V DC
Voltage Range: +15 V to -10 V
Current Capacity: 5–10 A
Switching Frequency: Up to 20 kHz
Galvanic Isolation Voltage: ≥2500 V AC
Operating Temperature: -20°C to +55°C
Storage Temperature: -40°C to +85°C
Control Voltage: 24 V DC
Signal Voltage: 5 V/3.3 V
Switching Frequency:12–16 kHz
Current Ratings:55–160 kW
Overload Capacity: Typically 150%
Temperature: –10°C to +40°C
Humidity: ≤90% (non-condensing)
Trigger Voltage/Current:+15 V/-10 V
Switching Frequency: Up to 20 kHz
Isolation Voltage: ≥2000 V AC
Logic Supply: +24 V DC (±10%)
Gate Driver Supply: ±15 V DC
Operating Temperature: 0–55°C
Power Supply (Control Section): 24 V DC (±20%)
DC Link Voltage Handling:500–800 V DC
Motor Compatibility: up to 100s of kW
Switching Frequency: 2–16 kHz
Digital Inputs/Outputs:≥6 DI/DO
Analog Inputs:≥2 × ±10 V, 4–20 mA
Operating Temperature: 0–45°C
Voltage Range: 3-phase AC input
Frequency: 50/60 Hz (±5%)
DC Link voltage:510–720 V DC
Continuous Current (DC Link): Up to 60–80 A
Auxiliary Voltage Supply: 24 V DC
Aambient Temperature: 0–40°C
Supply Voltage: 24 V DC (±20%)
Power Consumption: ≤15 W
Motor Compatibility: up to 55 kW
Standard Communication:PROFIBUS DP
Operating Temperature: -20°C to +60°C.
Relative Humidity: ≤95% (non-condensing)
Voltage Range:380–480 V AC
Frequency: 50/60 Hz ±5%
Rated Current:20–200 A
Continuous Power: 10–150 kW
Operating Temperature: -10°C to +50°C (storage up to +70°C)
Number of inputchannels:8, isolated channels
Input frequency :0 to 10 kHz
Minimum input pulse width:40 µs
Pull-up resistance:68 kΩ (12 V DC or 24 V DC)
Filter:Filter for eliminating chattering can be set
Data update period:2 ms
PROFIBUS/MPI or PROFINET
Control Voltage: 24 V DC (±15%)
Output Switching Frequency: 1–16 kHz
Isolation Voltage: ≥2.5 kV AC
Operational Temperature: 0°C to +50°C
Inverter control board
IGD9 for devices 510-620 V DC
1300 A
Logic Supply Voltage: +24 V DC (±10%)
DIP Switches:0–10 V, 4–20 mA
Operating Temperature: 0°C to +40°C
Humidity: ≤95% (non-condensing)
Control Voltage: 24 V DC (±10%)
Isolation Voltage: ≤2.5 kV AC
Output Frequency: ≤20 kHz
Max Output Current: 3–5 A
Signal Logic: 0–24 V DC control signals
Operating Temperature: –10°C to +55°C
Storage Temperature: –40°C to +85°C
Relative Humidity: ≤93% (non-condensing)
Logic Circuit: 24 V DC
Isolation Voltage: ≥2.5 kV AC
Output Current: Up to 2–3 A
Frequency Range: 1 kHz–20 kHz
Operating Temperature: 0°C to +60°C
Humidity: ≤95% (non-condensing)
SIMOTRAS HD Snubber circuit
Rated Voltage (Unm): 690 V AC (50/60 Hz)
Operating Voltage Range: 200–750 V AC
Capacitance: 10–50 μF
Impedance Range: 5–50 Ω at 50 Hz
Dielectric Strength: 2.5 kV AC
Points:32, commoned
Nominal input voltage:24 V DC
Operational voltage range:15–30 V DC
Absolute maximum input voltage:33 V DC
Absolute maximum reverse input voltage:–0.6 V DC
Input delay:<10 ms, On to Off or Off to On
ADC scan time:<1 ms for all 32 points
Points:16, commoned
Nominal output voltage:24 V DC
Operational voltage range:15–30 V DC
Absolute maximum output voltage:33 V DC
Absolute maximum reverse input voltage:–0.6 V DC
Leakage to load (Off-state):<1 mA
On-state voltage drop:<1 V DC @ 1.5 A
Loop-back scan time:<1 ms for all 16 points
Points:32, commoned
Nominal input current:4–20 mA DC
Operational current range:2–22 mA DC
Absolute maximum field voltage:33 V DC
Absolute maximum input current:50 mA DC
Input bandwidth (3dB):16 Hz
Source impedance:180 Ω
Resolution:12 bits
Absolute error:0.15% of full scale (20 mA)
Diagnostic:Force-to-value diagnostic (FVD)
Scan time:<1 ms for all 32 points
Offers a distance-to-spot ratio of 50:1
Works with most K-type thermocouples
Allows easy access to advanced features
with soft-key buttons and graphical display
Captures up to 99 points of data for
quick downloading to a PC through the USB connection
Quickly identifies problems with MIN, MAX, AVG, and DIF functions
Easily adapts to lighting conditions with a two-level backlight
DBV / dBm measurement
1 μV resolution in DC mV range
Current measurement 20 A
(30 seconds momentary, 10 A continuous)
Peak capture function to record transients as fast as 250 μs
Continuity / Conductance / Capacitance
Resistance and continuity
Duty cycle & pulse width measurement
Min / Max / Average with Time Stamp to record signal fluctuations
Real time and elapsed time modes
CAT III 1000 V / CAT IV 600 V safety rated