
PlantCruise 50,000 SCADA Points Adder
PlantCruise 50,000 SCADA Points Adder
to Database Size
PlantCruise SCADA Point Adder 50,000 POINT
PlantCruise 25,000 SCADA Points Adder
PlantCruise 25,000 SCADA Points Adder
to Database Size
PlantCruise SCADA Point Adder 25,000 POINT
PlantCruise 10,000 SCADA Points Adder
PlantCruise 10,000 SCADA Points Adder
to Database Size
PlantCruise SCADA Point Adder 10,00 POINT
PlantCruise 8,000 SCADA Points Adder
PlantCruise 8,000 SCADA Points Adder
to Database Size
PlantCruise SCADA Point Adder 8,000 POINT
PlantCruise 5,000 SCADA Points Adder
PlantCruise 5,000 SCADA Points Adder
to Database Size
PlantCruise SCADA Point Adder 5,000 POINT
PlantCruise 2,000 SCADA Points Adder
PlantCruise 2,000 SCADA Points Adder
to Database Size
PlantCruise SCADA Point Adder 2,000 POINT
PlantCruise 1,000 SCADA Points Adder
PlantCruise 1,000 SCADA Points Adder
to Database Size
PlantCruise SCADA Point Adder 1,000 POINT
PlantCruise 100 SCADA Points Adder
PlantCruise 100 SCADA Points Adder
to Database Size
PlantCruise SCADA Point Adder 100 POINT
PlantCruise 2,000 Process Points Redundancy Adder
Database Size Expansions
PlantCruise 2,000 Process Points Redundancy Adder
to Database Size
Software License
PlantCruise DCS System
Requires PlantCruise Base
PlantCruise 1,000 Process Points Redundancy Adder
Database Size Expansions
PlantCruise 1,000 Process Points Redundancy Adder
to Database Size
Software License
PlantCruise DCS System
Requires PlantCruise Base
PlantCruise 100 Process Points Redundancy Adder
Database Size Expansions
PlantCruise 100 Process Points Redundancy Adder
to Database Size
Software License
PlantCruise DCS System
Requires PlantCruise Base (CV-DBASE1)
PlantCruise 2,000 Process Points Adder
PlantCruise 2,000 Process Points Adder
to Database Size
Software License
PlantCruise DCS System
Requires PlantCruise Base (CV-DBASE1)
PlantCruise 1,000 Process Points Adder
PlantCruise 1,000 Process Points Adder
to Database Size
Software License
PlantCruise DCS System
Requires PlantCruise Base (CV-DBASE1)
PlantCruise 100 Process Point Adder
PlantCruise 100 Process Points Adder
to Database Size
Software License
PlantCruise DCS System
Requires PlantCruise Base (CV-DBASE1)
PlantCruise Redundancy Base Software
Redundancy Module for PlantCruise
Requires PlantCruise Base
High-availability DCS
Xeon 4-core 2.4GHz+
16GB (32GB recommended)
500GB SSD
PlantCruise Process points with base
Active Directory/LDAP
PlantCruise (Process Points License)
Up to 50,000
Scan Rate:100ms (configurable)
Alarm Handling:10,000 alarms/sec
Historical Data Storage:1M tags @ 1-sec intervals
Redundancy Switchover:<1 sec
PlantCruise Base Software
SCADA Interfaces
OPC and Data Exchange Options
Version Designation:CV-DBASE1
Type:Process Control System
Architecture:Distributed Client-Server
Deployment:Virtualized/Physical
Real-time Control:100ms scan cycles
I/O Capacity:50,000 points
Alarm Management:10,000 alarms/sec
Historical Storage:1M tags @ 1sec intervals
Redundancy:Hot standby servers
Solar Turbines Board
Solar Turbines Board
16 Channel Relay Module
MODULE MONITORING SOLAR 1.0AMP
Input Voltage:24V DC ±10%
Power Consumption:8W max
Input Channels:4 x BNC (Velocity/Acceleration)
Signal Range:±5V
Frequency Response:2Hz - 10kHz (±3dB)
A/D Resolution:16-bit
Safety Builder R100.3 software
Model Number:FS-SMSB-ST-120
Software Name:Safety Builder R100.3
Processor:Intel i7 2.8GHz or equivalent
RAM:16GB (32GB recommended)
Storage:500GB SSD
Basic Windows 2000/XP
DIGITAL INPUT MODULE
DIGITAL INPUT MODULE
SIMATIC S7-300
24 VDC
20 PIN
OPTICALLY ISOLATED
16DI
REPLACED BY: 6ES7321-1BH02-0AA0
Eddy Current Displacement Sensor
Linear Measurement Range 2 mm (80 mils)
Initial Air Gap 0.5 mm (20 mils)
Frequency Range (-3 dB):0 to 20,000 Hz
Rise Time:<15µs
Supply Voltage Range-23V to -32V
Airflow monitor
Effective solution without costly electronics
Dependable mechanical operating principle
Direct monitoring of the cooling air
Extremely compact dimensions
Versatile mounting options
Indication of malfunctions or correct operation
Relay module
Nominal input voltage
24 VDC
2 changeover contacts
Limiting continuous current
8 A; with gold contacts
Red status indicator
Module width: 15 mm 2,50 mm²
gray
Switched-mode power supply
Pro; 1-phase
48 VDC output voltage
5 A output current
TopBoost + PowerBoost
DC OK contact
Intelligent travel transmitter
One-touch zero or full position setting
Sensor disconnect self-diagnosis function
Standard 35mm DIN rail mounting
When the transmitter is used with our sensors,
the cable length between the two can reach up to 100m
Copyright Notice © 2004-2024 amikong.com All rights reserved
Disclaimer: We are not an authorized distributor or distributor of the product manufacturer of this website, The product may have older date codes or be an older series than that available direct from the factory or authorized dealers. Because our company is not an authorized distributor of this product, the Original Manufacturer’s warranty does not apply.While many DCS PLC products will have firmware already installed, Our company makes no representation as to whether a DSC PLC product will or will not have firmware and, if it does have firmware, whether the firmware is the revision level that you need for your application. Our company also makes no representations as to your ability or right to download or otherwise obtain firmware for the product from our company, its distributors, or any other source. Our company also makes no representations as to your right to install any such firmware on the product. Our company will not obtain or supply firmware on your behalf. It is your obligation to comply with the terms of any End-User License Agreement or similar document related to obtaining or installing firmware.