Binary Control Module
Range: Typically 20.4 V DC
Series: 83SR Safety Relay System
Channel-to-Backplane/Logic: Yes
Isolation Voltage: Typically 250V AC
Safety Certification: TÜV Rheinland certified
FTA interconnection cable
System Interconnection Cable For Chassis IO
FS-SICC-0001/Lx (where × = length)
20 × AWG 22 (= 0.34 mm²) double shielded
9.93 mm / 0.39 in
3 = 3m
MNS iS Motor Control Center
PROFIBUS DP (-V0) and PROFIBUS DP-V1
MODBUS RTU / TCP
Power Supply 24V DC
Power Consumption Typical 1000mA
INVERTER TRIGGER DRIVER BOARD
Input Voltage: 24 V DC
Operating Temperature: -10°C to +70°C.
Storage Temperature: -25°C to +85°C.
Humidity: 5% to 95% non-condensing.
AC drive
Output Current: 105 A
Integrated Filter: L500
Frame Size: R7
Cooling Method: Air cooling
Voltage:3-phase 380–480 V AC (±10%)
Frequency:47–63 Hz
Input Current:120 A
Motor Power Range:55–75 kW
Apparent Power (S1):89 kVA (at 480 V)
Pressductor PillowBlock Web Tensiometer
Measurement Range:0–50 kN
Accuracy"±0.5% of full scale (typical)
Digital Option:RS-485 Modbus RTU
Excitation Voltage:10–30 V DC
Bridge Resistance:350 Ω ±1%
Cable Length:Standard 10m
Overload Capacity:150% of rated range
CONTROL DISTRIBUTION BOARD
Rated Operational Voltage (Ue) :230/400V AC (50/60 Hz)
Rated Insulation Voltage (Ui):500V AC
Rated Current (In):Up to 100A
Short-Circuit Capacity (Icn):10 kA
Mounting Depth:10–120 mm
Material :Galvanized steel
Main Circuit Interface Card
System Voltage:24 V DC (19.2–30 V DC)
Power Consumption:≤ 1.5 W (typical)
Communication Protocol:Profibus DP-V1
Modbus RTU (via FCI module)
Isolation:Galvanic isolation between
HRC FUSE LINK
Fuselink
rated current 500A
size NH3
rated voltage 500VAC / 250VDC
utilization category gG
rated breaking capacity 120 kA (AC) / 80 (kA DC)
Binary Input Unit
Input Channels:16
Input Type:Dry Contact or 24V DC Sourcing
Voltage Range:19–30 V DC
Input Current:3–5 mA per channel
Logic Levels:"1" (ON): +15–30 V DC
"0" (OFF): 0–5 V DC
Response Time:≤ 2 ms (ON/OFF)
Overvoltage Protection:60 V DC (continuous), 75 V DC (1s)
Isolation:1500 V AC
Digital Output Module
Optional redundancy
Electronic Overcurrent protection
Configurable Safe-state (FAILOPT)
Extensive internal diagnostics to ensure data integrity
Latched, pulsed or pulse-width modulated output(per channel)
UNITROL CARD
Input Voltage :24 V DC (±20%)
or 48 V DC (±20%)
Analog Inputs:6 channels
Digital Inputs:8 channels
Analog Outputs:4 channels
(0–20 mA / 4–20 mA)
Digital Outputs:6 channels
Processing Speed:32-bit DSP
Communication:RS-485 Modbus RTU, CANopen
I/O Module Adaptor
Data Transfer Rate:Up to 12 Mbps (PROFIBUS)
Isolation Voltage:1.5 kV AC
Power Supply:24 V DC
Power Consumption:≤ 1.2 W
C300 Series Power Supply
Power System (20A)
Redundant (2 power supplies)
120/240 VAC
with 24VBackup Battery Assembly
Binary I/O Module
Input Channels:16x Binary Inputs
Output Channels:10x Binary Outputs
Contact Rating (Outputs):5A @ 250V AC/30V DC
Input Voltage Ranges:24/48/110/125 V DC
Input Threshold (ON):>70% of rated voltage
Response Time:<10 ms
Isolation Voltage:2.5 kV AC
Power Consumption:≤ 5 W

Copyright Notice © 2004-2024 amikong.com All rights reserved
Disclaimer: We are not an authorized distributor or distributor of the product manufacturer of this website, The product may have older date codes or be an older series than that available direct from the factory or authorized dealers. Because our company is not an authorized distributor of this product, the Original Manufacturer’s warranty does not apply.While many DCS PLC products will have firmware already installed, Our company makes no representation as to whether a DSC PLC product will or will not have firmware and, if it does have firmware, whether the firmware is the revision level that you need for your application. Our company also makes no representations as to your ability or right to download or otherwise obtain firmware for the product from our company, its distributors, or any other source. Our company also makes no representations as to your right to install any such firmware on the product. Our company will not obtain or supply firmware on your behalf. It is your obligation to comply with the terms of any End-User License Agreement or similar document related to obtaining or installing firmware.