Supply Voltage:24V DC
Power Consumption:< 2W
Isolation:500V AC
Operating Temp:-25°C to +70°C
Storage Temp:-40°C to +85°C
Humidity:5–95% (non-condensing)
Compact installation of I/O modules
Up to 16 channels of field signals
and process power connections
Connections to ModuleBus and I/O modules
Mechanical keying prevents
insertion of the wrong I/O module
Latching device to DIN rail for grounding
DIN rail mounting
Input Voltage: 24 VDC
Power Tolerance: Operates within ±10%
Analog Signals: 4–20 mA or 0–10 V
Operating Temperature: -25°C to +70°C
Humidity: ≤95% non-condensing
Voltage: Typically 24 VDC (±10%)
Power Consumption: <5–10 W
Digital Inputs: 8–16 channels
Analog Inputs: 4-20 mA/0-10 V
Temperature Range: -20°C to +70°C
Line monitored digital input
Non line monitored digital input
Line monitored ESD input (on Channel 32)
Analog input 0-20mA or 4-20mA
Digital output (0.5 Amp) configurable line monitoring
Multiple digital output (1 Amp or 2 Amp)
with or without line monitoring
Analog output 0-20mA or 4-20mA
DIGITAL INPUT MODULE
32 CHANNEL
24 VDC
ISOLATED
50 MA
PULSE WIDTH OUTPUT FUNCTION
TIME-PROPORTIONAL OUTPUT FUNCTION
STATUS DISPLAY
NO EXPLOSION PROTECTION
Number of input channels:64
Rated input voltage:24 V DC
Input ON voltage:20 to 26.4 V DC
Input OFF voltage :5.0 V DC or less
Input current :2.5 mA±20 % / channel
Maximum allowable input voltage:30.0 V DC
Input response time :8 ms or less
Minimum ON detection time:20 ms
Maximum ON/OFF cycle:25 Hz
Maximum current consumption:500 mA (5 V DC)
EC402 ESB Bus Coupler Module
5 Standard type with no explosion protection
E Standard type with explosion protection
0 Basic type
1 With ISA Standard G3 option
Operating Voltage:24 V DC
INVERTER MOTHERBOARD
FOR ACS580
3AXD50000716975
Input Voltage Range:380–500V AC (3-phase)
DC Bus Link:Integrated protection
Control Voltage:24V DC
Logic Board Power:Switch-mode PSU
Communication Isolation:1500V AC reinforced
Operating Temp:-15°C to +45°C
Input Voltage:380–690V AC
Output Power:up to 630 kW
Control Voltage:24V DC (±10%)
Ambient Operation:-15°C to +50°C
Humidity Protection:<95% non-condensing
CE Mark: Low Voltage Directive
Digital I/O: 6 programmable DI
Analog I/O: 2x 0–10V/4–20mA
Input Power (AC):400–690V (±10%) 3-phase
Motor Power Range:250kW–1.5MW
Control Voltage:Single-phase 26V DC to 30V DC (±15%)
Operating Temp:-15°C to +50°C
Harsh Environment:UL 1203
Busbar Terminals:values 8.9Nm ±0.5
AS-Interface Safety ATEX Gateway
Input Voltage:200–690V AC (-15%/+10%)
Power Range:15–400kW
Control Voltage:Single-phase 24V DC
Relay Outputs:4 × Form-A
AF-650PG: Profibus DP or CANopen