990 Vibration Transmitter
05 0-5 mils pp (0-125 μm pp)
70 7.0 meters (23.0 feet)
01 35 mm DIN rail clips
00 Not required
3300 XL 8 mm Reverse Mount Probes
330101 3300 XL 8 mm Probe
3/8-24 UNFthread, without armor
Minimum unthreaded length: 3.3 in
Minimum case length: 5.3 in
10 1.0 meter (3.3 feet)
12 Miniature coaxial ClickLocconnector
FluidLoc cable
05 CSA, ATEX, IECEx Approvals
3300 XL 8 mm Reverse Mount Probes
330105-02-12-CC-DD-EE3/8-24 UNF threads
15 1.5 meter (4.9 feet)
12 Miniature ClickLoc coaxialconnector
FluidLoc cable
05 CSA, ATEX, IECEx Approvals
3300 XL 8 mm Proximity Probes
330101 3300 XL 8 mm Probe
3/8-24 UNFthread, without armor
Minimum unthreaded length: 1.6 in.
Minimum case length: 2.8 in
10 1.0 meter (3.3 feet)
12 Miniature coaxial ClickLocconnector
FluidLoc cable
00 Not required
3300 XL 8 mm Proximity Probes
330101 3300 XL 8 mm Probe
3/8-24 UNFthread, without armor
Minimum case length: 1.0in
10 1.0 meter (3.3 feet)
02 Miniature coaxial ClickLocconnector
standard cable
00 Not required
3300 XL 8 mm Proximity Probes
330101 3300 XL 8 mm Probe
3/8-24 UNFthread, without armor
Minimum case length: 4.0 in
10 1.0 meter (3.3 feet)
02 Miniature coaxial ClickLocconnector
standard cable
00 Not required
3300 NSv Proximity Probes
330904 3300 NSv Probe
M8X1 thread, witharmor
Minimum unthreaded length:50 mm
Minimum length: 140 mm
05 0.5 meter (20 in)
02 Miniature coaxial ClickLoc connector
standard cable
05 Multiple Approvals
3300 XL 25 mm Proximitor Sensor
3300 XL 25 mm Proximitor Sensor
9 1 9.0 metres (29.5 feet)
system length,DIN mount
0 0 No Approvals
3300 XL 25 mm Proximitor Sensor
3300 XL 25 mm Proximitor Sensor
5 1 5.0 metres (16.4 feet)
system length,DIN mount
0 0 No Approvals
3300 XL 8 mm Proximity Probes
330103 3300 XL 8 mm Probe
M10 x 1 thread,without armor
Minimum case length: 130 mm
10 1.0 meter (3.3 feet)
12 Miniature coaxial ClickLocconnector
FluidLoc cable
05 CSA, ATEX, IECEx Approvals
Interconnect Cable
3 twisted pairs (6 conductors total)
Wire Gauge: 24 AWG
Impedance: 100 Ω ±10%
Capacitance: ≤30 pF/ft (pair-to-pair)
Max Voltage Rating: 300 V AC/DC
Operating: -40°C to +120°C (-40°F to +248°F)
3300 XL 11 mm Proximity Probes
330703 3300 XL 11 mm Probe
M14 x 1.5 thread,without armor
10 1.0 meter (3.3 feet)
01Miniature coaxial ClickLocconnector
with connectorprotector, standard cable
00 Not required
3300 XL 11 mm Proximity Probes
330703 3300 XL 11 mm Probe
M14 x 1.5 thread,without armor
10 1.0 meter (3.3 feet)
02 Miniature coaxial ClickLocconnector
standard cable
00 Not required
3300 XL 8 mm Proximity Probes
330104 3300 XL 8 mm Probe
M10 x 1 thread,with armor
Minimum case length: 70 mm
90 9.0 meters (29.5 feet)
02 Miniature coaxial ClickLocconnector
standard cable
05 CSA, ATEX, IECEx Approvals
3300 NSv Reverse Mount Probe
330907-05-30- CC-DD-EE M10X1 threads
05 0.5 meter (20 in)
02 Miniature coaxial ClickLocconnector
standard cable
00 Not required
3300 XL 8 mm Proximity Probes
330101 3300 XL 8 mm Probe,
3/8-24 UNFthread, without armor
Minimum case length: 1.8in
10 1.0 meter (3.3 feet)
02 Miniature coaxial ClickLocconnector
standard cable
05 CSA, ATEX, IECEx Approvals
3300 XL 8 mm Proximity Probes
330101 3300 XL 8 mm Probe,
3/8-24 UNFthread, without armor
Minimum case length: 2.6in
10 1.0 meter (3.3 feet)
02 Miniature coaxial ClickLocconnector
standard cable
05 CSA, ATEX, IECEx Approvals
3300 XL 8 mm Proximity Probes
330101 3300 XL 8 mm Probe,
3/8-24 UNFthread, without armor
Minimum case length: 4.4 in
10 1.0 meter (3.3 feet)
02 Miniature coaxial ClickLocconnector
standard cable
05 CSA, ATEX, IECEx Approvals
3300 XL 8 mm Proximity Probes
330103 3300 XL 8 mm Probe
M10 x 1 thread,without armor
Minimum unthreaded length: 120 mm
Minimum case length: 160 mm
10 1.0 meter (3.3 feet)
02 Miniature coaxial ClickLocconnector
standard cable
05 CSA, ATEX, IECEx Approvals
Proximitor Probe Extension Cable
0 Hz (DC) to 10 kHz as the frequency response
Non-interference
Systems with Gap-to-Voltage Transducers
Calculates Dynamic and Static Distances
3300 XL 8 mm Proximity Probes
330101 3300 XL 8 mm Probe
3/8-24 UNFthread, without armor
Minimum case length: 5.3 in
10 1.0 meter (3.3 feet)
02 Miniature coaxial ClickLocconnector
standard cable
05 CSA, ATEX, IECEx Approvals
3300 NSv Proximity Probes
330901 3300 NSv Probe
1/4-28 UNF thread,without armor
Minimum case length: 1.0 in
10 1.0 meter (39 in)
02 Miniature coaxial ClickLoc connector
standard cable
05 Multiple Approvals
3300 XL 8 mm Proximity Probes
330103 3300 XL 8 mm Probe
M10 x 1 thread,without armor
Minimum case length: 2.1 in
05 0.5 meter (1.6 feet)
11Miniature coaxial ClickLocconnector
with connectorprotector, FluidLoc cable
05 CSA, ATEX, IECEx Approvals
3300 XL 8 mm Proximity Probes
330101 3300 XL 8 mm Probe
3/8-24 UNFthread, without armor
Minimum case length: 2.5 in
05 0.5 meter (1.6 feet)
02 Miniature coaxial ClickLocconnector
standard cable
05 CSA, ATEX, IECEx Approvals
3300 XL 8 mm Proximity Probes
330903 3300 NSv Probe
M8X1 thread,without armor
Minimum length: 40 mm
05 0.5 meter (20 in)
02 Miniature coaxial ClickLoc connector
standard cable
00 Not required
Copyright Notice © 2004-2024 amikong.com All rights reserved
Disclaimer: We are not an authorized distributor or distributor of the product manufacturer of this website, The product may have older date codes or be an older series than that available direct from the factory or authorized dealers. Because our company is not an authorized distributor of this product, the Original Manufacturer’s warranty does not apply.While many DCS PLC products will have firmware already installed, Our company makes no representation as to whether a DSC PLC product will or will not have firmware and, if it does have firmware, whether the firmware is the revision level that you need for your application. Our company also makes no representations as to your ability or right to download or otherwise obtain firmware for the product from our company, its distributors, or any other source. Our company also makes no representations as to your right to install any such firmware on the product. Our company will not obtain or supply firmware on your behalf. It is your obligation to comply with the terms of any End-User License Agreement or similar document related to obtaining or installing firmware.