本特利TK3-2E 14700-02ATK32E
DISCONTINUED BY MANUFACTURER
WOBULATOR
CALIBRATION INSTRUMENT
1AMP
190-250VAC MAX
50/60HZ
90PSI MAX/6.2BAR
STIMULATES SHAFT VIBRATION AND POSITION
FOR CALIBRATING BENTLY NEVADA MONITORS
(14700-01)
Linear Measurement Range 2 mm (80 mils)
Initial Air Gap 0.5 mm (20 mils)
Incremental Scale Factor (ISF) ISO:
8 V/mm (203.2 mV/mil) ± 5%@
temperature range 0 to 45°C(+32 to +113°F)
Deviation from best fit straight line(DSL)
± 0.025 mm (± 1 mil)@
temperature range 0 to 45°C(+32 to +113°F)
Minimum Shaft Diameter 25 mm (0.79”)
Linear Measurement Range:2 mm (80 mils)
Initial Air Gap:0.5 mm (20 mils)
Incremental Scale Factor (ISF):
ISO: 8 V/mm (203.2 mV/mil) ± 5%
temperature range 0 to 45°C(+32 to +113°F)
Deviation from best fit straight line(DSL)
± 0.025 mm (± 1 mil)
temperature range 0 to 45°C(+32 to +113°F)
Length:5.0 meters (16.4 feet)
Conductor Size:0.382 mm² (22 AWG)
Temperature Range:-29°C to +121°C (-20°F to +250°F)
Voltage Rating:300V AC/DC
Minimum Bend Radius:≥12× cable diameter