SINGLE MOTOR MODULE
SINAMICS S120
SINGLE MOTOR MODULE
INPUT: DC 600V
OUTPUT: 3AC 400V, 85A FRAME
SIZE: BOOKSIZE INTERNAL AIR COOLING
OPTIMIZED PULSE SAMPLE
AND SUPPORT OF THE EXTENDED
SAFETY INTEGRATED FUNCTIONS INCL
DRIVE-CLIQ CABLE
INTERFACE MODULE
TELEPERM XP INTERFACE MODULE IM308C
INTERFACE MODULE LOCATED IN THE AP OR EG FOR
THE CONNECTION BETWEEN AP AND ET200
INTELLIGENT FIELD DEVICES,
FOR THE SUPPORT OF
THE CENTRALIZED ENGINEERING OF
THE INTELLIGENT FIELD DEVICES
SENSOR CONDITIONING
TELEPERM XP MODULE FUM 210
FOR SENSOR CONDITIONING FAST BINARY SIGNAL ACQUISITION,
OR DRIVE CONTROL SENSOR, MONITORING AND SIGNAL.
MODULE CONDITIONING:
14 CHANGEOVER OR 28 SINGLE CONTACTS
WITH SENSOR SUPPLY AND MONITORING,
28 BINARY INPUTS WITHOUT SENSOR SUPPLY
Symphony Plus I/O Open Loop Control Card
Migration of Contronic P, E, 3 to System 800xA with AC 870P
Migration of Maestro UX Operations
Maestro UX and System 800xA Operations in parallel
Evolution of SymBatch to 800xA Batch Management
BINARY SIGNAL COUPLING MODULE
TELEPERM XP MODULE FUM 211,
BINARY SIGNAL COUPLING MODULE
16 BINARY INPUTS
WITE ELECTRICAL ISOLATION
VIA OCTOCOUPLERS 16 BINARY
OUTPUTS 250 MA (WITH LIMITATION)
STEADY OR FLASHING (8, 2, 0,5 HZ)
SUITABLE TO CONNECT CONSOLE CONTROL TILES.
CAPABLE FOR 2 DESK TILES USE IN SPPA-T200
SENSOR CONDITIONING
TELEPERM XP MODULE FUM 210
SENSOR CONDITIONING
FAST BINARY SIGNAL ACQUISITION
OR DRIVE CONTROL SENSOR,
MONITORING AND SIGNAL
MODULE CONDITIONING:
14 CHANGEOVER
28 SINGLE CONTACTS
WITH SENSOR SUPPLY AND MONITORING
28 BINARY INPUTS
WITHOUT SENSOR SUPPLY
DP/AS-i Link Advanced
SIMATIC NET,
DP/AS-INTERFACE LINK ADVANCED;
GATEWAY PROFIBUS
DP/AS-INTERFACE WITH MASTER PROFILE M3, M4 ACC.
TO EXTENDED AS-I SPEC.
V3.0 FOR INTEGRATION IN PROFIBUS DP;
DOUBLE MASTER WITH DISPLAY;
DEGREE OF PROTECTION IP20.
Standard Operator Terminal
18…32V DC (24V DC nom)
Panelview 300
24 Volts DC
240 KB
PanelView 300 Standard Operator Terminals
Monochrome transflective LCD with LED backlight
logic module
230RCE,logic module
Display PS/I/O: 115V/230V/relay
8 DI/4 DO, memory
230 V AC/DC
400 blocks, modular expandable
Current Input Module
16, isolated
4 to 20 mA
270 Ω (20 mA) to 350 Ω (4 mA)
±16 µA
230 mA (5 V DC), 540 mA (24 V DC)
FASTBUS-Modules
FASTBUS master modules with 1 or 2 FO interfaces
FASTBUS slave modules with 1 or 2 FO interfaces
FASTBUS slave modules with integrated power supply
Up to 15 distributed substations
Distances to between 2 stations:
40 m for POF cables
150 m for HCS cables
180 m for special HCS cables
Status display (RUN/ERR) and display for fiber type
Minimal signal delay
Analog Input Module
2 or 4 analog inputs
Input current 0 to 20 mA
Input impedance 75 Ω
Resolution: 16 bit
Refresh cycle time 250 ms / channel
Galvanic isolation of channels
Galvanic isolation from system
Monitoring of internal voltages
Processor module
CPU module ME203/EN (33MHz)
8MB DRAM / 512kB SRAM
8MB file-flash
1x Eth100
1x RS232
1x RS232/422/485
Integrated power supply 17W
PCC slot
CPU module
CPU module 386EX (33MHz)
8MB DRAM / 512kB SRAM
8MB file-flash
1x CAN/CANopen
1x RS232
1x RS232/422/485
Integrated power supply 17W
PCC slot
Serial Interface Module
4 interfaces on one module
Any number of interfaces possible per controller
RS232 / RS422 / RS485 can be combined
High speed interfaces with up to 1.5 Mbaud
Auto-flow control for automatic handshake
Integrated terminating resistors (connect/disconnect)
Interfaces galvanically isolated
Galvanic isolation from system and between interfaces 500 V

Copyright Notice © 2004-2024 amikong.com All rights reserved
Disclaimer: We are not an authorized distributor or distributor of the product manufacturer of this website, The product may have older date codes or be an older series than that available direct from the factory or authorized dealers. Because our company is not an authorized distributor of this product, the Original Manufacturer’s warranty does not apply.While many DCS PLC products will have firmware already installed, Our company makes no representation as to whether a DSC PLC product will or will not have firmware and, if it does have firmware, whether the firmware is the revision level that you need for your application. Our company also makes no representations as to your ability or right to download or otherwise obtain firmware for the product from our company, its distributors, or any other source. Our company also makes no representations as to your right to install any such firmware on the product. Our company will not obtain or supply firmware on your behalf. It is your obligation to comply with the terms of any End-User License Agreement or similar document related to obtaining or installing firmware.