KJ4001X1-CC1 4-Wire Terminal Block
12P0733X042
DISCONTINUED BY MANUFACTURER
TERMINAL BLOCK
4WIRE
KJ3001X1-BA1 Digital Input Isolated
KJ3001X1BA1
DISCONTINUED BY MANUFACTURER
INPUT MODULE
8CHANNEL
24VDC
ISOLATED CARD
KJ3002X1-BG2 Thermocouple Module
KJ3002X1BG2
DISCONTINUED BY MANUFACTURER
THERMOCOUPLE
MV FINAL ASSEMBLY
INPUT MODULE
8POINT
ANALOG
Tariff Code: 8538903000
Country of Origin: United Kingdom
KJ4001X1-CJ1 32-Channel Terminal Block
KJ4001X1CJ1
DISCONTINUED BY MANUFACTURER
TERMINAL BLOCK 32CHANNEL 1AMP 30VDC
AVAILABLE
SURPLUS
NEVER USED
2 YEAR RADWELL WARRANTY
Analog Output Module
CCPAOH01
DISCONTINUED BY MANUFACTURER
OUTPUT MODULE
ANALOG
AO HART
16 CHANNEL
.46 AMP
24 VDC
PP C322 BE1 Processing Unit
PROCESSOR MODULE
Clock Speed: 500 MHz–1 GHz
RAM: 512 MB–2 GB
Ethernet Ports: 2–4 ports (10/100/1000 Mbps)
Fieldbus Support: PROFIBUS, Modbus
Operating Temperature: -25°C to +70°C (-13°F to +158°F).
Humidity: 5–95% RH
LCD Operator Panel
HIEE200130R0002
DISCONTINUED BY MANUFACTURER
OPERATION PANEL 24V TYPE AF-C094-AE02
TC/RTD Input Module
Number of input channels: 16, isolated channels
Allowable input voltage :±5 V
Input resistance:1 MΩ or larger
Maximum currentconsumption:350 mA (5 V DC)
Measurement current:RTD: 1 mA
Resistance ofsignal source plus wiring:150 Ω or less
Twin Robot Xbar (TRX)
Optimized power distribution efficiencyplus
the stability of a double subjectio
8 Degrees from 2 IRB 760 (4+4)
2 actuators for crossbar tilting
ββ’, γ-γ‘ and crossbar side shifting
obtained by IRB 760 arm positions
Voltage Regulating I/O Module
Load (Output Mode):Min. 1 kΩ
Input Impedance:Typically ≥ 100 kΩ
Accuracy:±0.1% of full scale (typical)
Resolution:16-bit
Ripple & Noise:< 1 mV RMS
Bailey Board
±10V DC, 0-10V DC
Load (Output Mode):Min. 1 kΩ
Input Impedance:≥ 100 kΩ
Temperature Drift:±50 ppm/°C (typical)
Isolation Voltage:1500V AC
> 120 dB @ 50/60 Hz
SM9 Module
Points:8, 16, or 32 points
Rated Voltage:24V DC
Input Current (DI):Typically 5-10 mA @ 24V DC
Load Current (DO):0.5A - 2.0A per point
Off-state Leakage Current:≤ 0.1 mA
On-state Voltage Drop:≤ 1.5V - 2.5V
Single Loop Controller
SLC02
Digital Single Loop Controller
Power Supply:100-240V AC
Power Consumption:Typically 5 VA
Display Resolution:1°C / 0.1°C
Smart Interface Unit
SIU010
Smart Interface Unit
24V DC (±20%)
Power Consumption "5W
Protocol PROFIBUS DP-V0/V1
9.6 kbps to 12 Mbps (auto-sensing)

Copyright Notice © 2004-2024 amikong.com All rights reserved
Disclaimer: We are not an authorized distributor or distributor of the product manufacturer of this website, The product may have older date codes or be an older series than that available direct from the factory or authorized dealers. Because our company is not an authorized distributor of this product, the Original Manufacturer’s warranty does not apply.While many DCS PLC products will have firmware already installed, Our company makes no representation as to whether a DSC PLC product will or will not have firmware and, if it does have firmware, whether the firmware is the revision level that you need for your application. Our company also makes no representations as to your ability or right to download or otherwise obtain firmware for the product from our company, its distributors, or any other source. Our company also makes no representations as to your right to install any such firmware on the product. Our company will not obtain or supply firmware on your behalf. It is your obligation to comply with the terms of any End-User License Agreement or similar document related to obtaining or installing firmware.