Current Input Module
Number of input channels 16 channels,
module isolation (*5)
Rated input range 4 to 20 mA
Permissible input range 0 to 25 mA
Input impedance during Power-OFF 500 kΩ minimum
Data update frequency 40 ms
Temperature drift ±16 µA/10 °C
Withstand voltage 1.5 kV AC between input signal and system for 1 minute
Current Output Module
8 channels, module isolation
1.25 to 23 mA
4 to 20 mA
230 to 600 Ω
±16 µA/10 ºC
1.5 kV AC between output signal and system for 1 minute
5 V system: 320 mA24 V system: 300 mA
Digital Input Module
16-channel, module isolation
6 mA ± 20 %
24 V DC +20 % / -10 % (*4), 10 mA or greater
24 V DC +20 % / -10 % (*3) (*4)Current capacity: 200 mA
30.0 V DC
40 ms maximum
2 kV AC between input signal and system for 1 minute, 16-input line collectivelyconnected
Digital Input Module
16-channel, module isolation
6 mA ± 20 %
24 V DC +20 % / -10 %
10 mA or greater
24 V DC +20 % / -10 %
Current capacity: 200 mA
30.0 V DC
40 ms maximum
2 kV AC between input signal and system for 1 minute
16-input line collectivelyconnected
Digital Input Module
16-channel, module isolation
24 V DC
1 V maximum
24 V DC, 3.4 A minimum
24 V DC + 20 % / -10 %
1.6 mA
0.2 A/output line (3.2 A in total output line) (*3) (*5)
120 to 685 Ω (*6
2 kV AC between output signal lines and system for 1 minute, 16-point input linescollectively connected (negative lines)
Digital Input Module
16-channel module isolation
6 mA ± 20 %
24 V DC +20 % / -10 %
Current capacity: 200 mA
24 V DC +20 % / -10 %
10 mA or greater
30.0 V DC
40 ms maximum
2 kV AC between input signal and system for 1 minute
16-input line collectivelyconnected
290 mA maximum (5 V DC)140 mA
maximum (24 V DC)
processor module
Voltage, Current, Thermocouple
Input Range:
Voltage: ±100mV to ±10V, Current: 4-20mA
Output Range:
Voltage: 0-10V, Current: 4-20mA
Accuracy: ±0.1% of full scale
Response Time: ≤ 250 ms
Power Supply: 24V DC
Isolation Voltage: 1500V AC
Operating Temperature: -10°C to +55°C
processor module
Voltage Current
Thermocouple
Voltage: ±100mV to ±10V, Current: 4-20mA
Output Range
Voltage: 0-10V, Current: 4-20mA
Accuracy: ±0.1% of full scale
Response Time: ≤ 250 ms
Power Supply: 24V DC
Isolation Voltage: 1500V AC
Operating Temperature: -10°C to +55°C
Pulse Input Module
8, isolated channels
0 to 10 kHz
500 V AC, for 1 minute
500 V AC, for 1 minute
40 µs
68 kΩ (12 V DC or 24 V DC)
300 mA (5 V DC),
400 mA (24 V DC)
ESB Bus Interface Slave Module
4 to 20 mA
16, isolated, standard switch-overresponse in redundant configuration
Between output and system: 1500 V AC, for 1 minute
0 to 750 Ω
Less than 0.65 mA
±48 µA
±16 µA/10 ˚C
230 mA (5 V DC), 540 mA (24 V DC)
Power Supply Module
Power Supply Module
Two modules in case of
dual-redundant configuration.
Power supply to the I/O modules
and supply power to the transmitters
BUS INTERFACE MASTER MODULE
16-Pointor8-Poin
KS Cable Interface Adapter
for Analog 16-channel
with ISA Standard G3 option
Connecting with AEA4D
Connectingwith MUB,TE16
Duplexed Field Control Unit
For Vnet/IP and FIO, for 19-inch Rack Mountable
100–120 V AC power supply
220–240 V AC power supply
Basic type
LFS1500 Control Function for Field Control Station (for Vnet/IP and FIO)
Current Input Module
16, isolated
4 to 20 mA
270 Ω (20 mA) to 350 Ω (4 mA)
±16 µA
230 mA (5 V DC), 540 mA (24 V DC)
Power Supply Module
Power Supply Module
Two modules in case of
dual-redundant configuration.
Power supply to the I/O modules
and supply power to the transmitters
The power supply terminals use M4 screws
Ethernet Communication Module
ETHERNET COMMUNICATION MODULE
STANDARD TYPE
NO EXPLOSION PROTECTION
BASIC TYPE
STYLE S1
NO DIRECT REPLACEMENT
Copyright Notice © 2004-2024 amikong.com All rights reserved
Disclaimer: We are not an authorized distributor or distributor of the product manufacturer of this website, The product may have older date codes or be an older series than that available direct from the factory or authorized dealers. Because our company is not an authorized distributor of this product, the Original Manufacturer’s warranty does not apply.While many DCS PLC products will have firmware already installed, Our company makes no representation as to whether a DSC PLC product will or will not have firmware and, if it does have firmware, whether the firmware is the revision level that you need for your application. Our company also makes no representations as to your ability or right to download or otherwise obtain firmware for the product from our company, its distributors, or any other source. Our company also makes no representations as to your right to install any such firmware on the product. Our company will not obtain or supply firmware on your behalf. It is your obligation to comply with the terms of any End-User License Agreement or similar document related to obtaining or installing firmware.