CENTRAL PROCESSING UNIT
CENTRAL PROCESSING UNIT
SIMATIC S7-400H
CPU 417H
FOR S7-400H
4 INTERFACES: 1 MPI/DP / 1 DP / 2 FOR SYNC MODULES
30 MB MEMORY (15 MB DATA/15 MB PROGRAM)
Digital output module
SIMATIC S7-300
Digital output SM 322
isolated, 8 DO, 24 V DC
0.5A (1x 8 DO)
Short-circuit protection diagnostics
1x 20-pole
Analog Input Module
SIMATIC S7-300
Analog input SM 331
isolated, 8 AI; +/-5/10V, 1-5 V, +/-20 mA
0/4 to 20 mA, 16 bit
Single rooting (60 V COM.)
4-channel operation: 10 ms
8-channel operation: 23-95ms, 1x 40-pole
DP/DP Coupler
SIMATIC DP
DP/DP coupler
Coupling module for connecting of two
PROFIBUSDP networks
redundant current infeed
FM350-1 Counter Module
6ES73501AH030AE0
COUNTER MODULE
SIMATIC S7-300
FM 350-1 FOR S7-300
500 KHZ
1 CHANNEL FOR CONNECTION
5V-24V INCREMENTAL ENCODERS
ISOCHRONOUS MODE
CPU 313C-2 DP Processor Module
CPU MODULE
SIMATIC S7-300
CPU 313C-2 DP
16 DIGITAL INPUT/16 DIGITAL OUTPUT
3 HIGH-SPEED COUNTERS (30 KHZ)
POWER SUPPLY 24 VDC
MEMORY 128 KB
Analog Input Module - Failsafe
ANALOG INPUT MODULE
SIMATIC 57
6 INPUTS
24 VDC
150 MA POWER SUPPLY
90 MA BACKPLANE
WITH HART SUPPORT
1X 20-POLE
SM 332 Analog Output Module
SIMATIC S7-300
Analog output SM 332
isolated by channel, 4 AI
Resolution 16 bit, 0-10 V
1-5 V, +/-10 V, +/-20 mA
0/4-20mA, 20-pole
suitable for isochronous mode
SYNC SUBMODULE
SIMATIC S7-400H
synchronizationmodule V4
for patch cable to 10 m
from CPU, max. 210 mA
Power loss, typ. 1.1 mW
PKGD CUSTOMER SP-SCRGD BOARD
PC BOARD
GATE DRIVER
SCR SILICON-CONTROLLED RECTIFIER
SELF-POWERED
Control Unit
Operating Voltage: 24 V DC ± 10%
Power Consumption: Typically 3 W
Operating Temperature Range: -20°C to +60°C
Storage Temperature Range: -40°C to +85°C
Humidity: 5% to 95% (non-condensing)
Logix5555 Processor 750KB memory
1756L55M12
DISCONTINUED BY MANUFACTURER 03/2011
CPU MODULE
CONTROLLOGIX LOGIX5555
WITH 750 KB MEM
1756-L55 BASE WITH 1756-M12 MEM BOARD
Tariff Code: 8537109060
Country of Origin: United States
Kinetix 6000 Axis Module
AXIS MODULE
KINETIX 6000
00 / 480 VAC
6.6 KW / 15 AMP INVERTER
WITH SAFE TORQUE-OFF FEATURE
REPLACED BY 2198-D032-ERS3
39SDM024DCCBN
DISCONTINUED BY MANUFACTURER
DISCRETE MODULE
0.23 AMP
24 VDC
9.96 MA INPUT
19-30 VDC RANGE
POINT I/O Analog Output Module
Series:POINT I/O
Module Type:Analog Output Module
Outputs:2 Single-Ended, Non-Isolated
Output Voltage:0-10 Volts
Current Load:3 milliamps
Conversion Type:Digital-Analog
Conversion Rate:20 microseconds
Data Format:Signed Integer
Resolution:14 bits
Power supply module
Primary voltage:100...240 V AC 85...264 V
Network frequency:50/60 Hz
Total useful secondary power:26 W
Immunity to microbreaks:10 ms
Operating altitude:0...2000 m
CPUs STEP7 programmable class C
3136CF13
DISCONTINUED BY MANUFACTURER
PLC MODULE
SPEED 7
128KB
16DI
16DO
PROFIBUS-DP MASTER
(CPU313SC/DPM)
REPLACEMENT: 313-6CF23
Simadyn D SP8 Power Supply
6DD16830BC0
DISCONTINUED BY MANUFACTURER
POWER SUPPLY UNIT
SP8
5V/52AMP
24 VDC
WITH FAN
SIMADYN
UR8FH
DISCONTINUED BY MANUFACTURER
CT/VT MODULE
HORIZONTAL UNIT
STANDARD - 4 CT/4 VT

Copyright Notice © 2004-2024 amikong.com All rights reserved
Disclaimer: We are not an authorized distributor or distributor of the product manufacturer of this website, The product may have older date codes or be an older series than that available direct from the factory or authorized dealers. Because our company is not an authorized distributor of this product, the Original Manufacturer’s warranty does not apply.While many DCS PLC products will have firmware already installed, Our company makes no representation as to whether a DSC PLC product will or will not have firmware and, if it does have firmware, whether the firmware is the revision level that you need for your application. Our company also makes no representations as to your ability or right to download or otherwise obtain firmware for the product from our company, its distributors, or any other source. Our company also makes no representations as to your right to install any such firmware on the product. Our company will not obtain or supply firmware on your behalf. It is your obligation to comply with the terms of any End-User License Agreement or similar document related to obtaining or installing firmware.