Power Supply Modules
Rated input voltage:AC 100V – AC 240V
Input voltage range:AC 85V ~ AC 264V
Input frequency:50 / 60 Hz (47 ~ 63 Hz)
Efficiency:65% or more
Output voltage:DC 5V (±2%)
Output current:3.0A
Over current protect:3.2A or more
Over voltage protect:5.5V ~ 6.5V
POWER SUPPLY MODULES
Program memory capacity: 3.5MB
I/O points(installable):6,144 points
Max. I/O memory contact:131,072 points
Symbolic variablearea(A):512KB
I variable:16KB
Flag variable F:4KB
Operator:18
Basic functionblock:43
POWER SUPPLY MODULES
Program memory capacity: 3.5MB
I/O points(installable):6,144 points
Max. I/O memory contact:131,072 points
Symbolic variablearea(A):512KB
I variable:16KB
Flag variable F:4KB
Operator:18
Basic functionblock:43
POWER SUPPLY MODULE
Rated input voltage:AC 100V – AC 240V
Input voltage range:AC 85V ~ AC 264V
Input frequency:50 / 60 Hz (47 ~ 63 Hz)
Efficiency:65% or more
Output voltage:DC 5V (±2%)
Output current:3.0A
Over current protect:3.2A or more
Over voltage protect:5.5V ~ 6.5V
PROGRAMMABLE LOGIC CONTROLLER
PROGRAMMABLE LOGIC CONTROLLER
512K BYTE
6144 POINTS MAX
3.5 MB
IEC
0-55 DEGREES C
MASTERLOGIC 200 SERIES
CPU MODULE
Program memory capacity: 640KB
I/O points(installable):3,072 points
Max. I/O memory contact:32,768 points
Symbolic variablearea(A):128KB
I variable:4KB
Flag variable F:4KB
Operator:18
Basic functionblock:43
CPU MODULE
Program memory capacity:4MB
I/O points(installable):6,144 points
Max. I/O memory contact:131,072 points
Symbolic variablearea(A): 512KB
I variable:16KB
Flag variable F:4KB
Operator:18
CPU module
Max. I/O: 3,072Pts
32kstep Programming
non-IEC
Standard
Power Supply:24V DC (±10%)
Power Consumption:15W typical, 25W max
Processor Speed:Dual-core 1.5 GHz
Memory:4GB RAM, 32GB Flash
I/O Capacity:Up to 512 points
3300 XL Standard Extension Cable
085 8.5 meters (27.9 feet)
10 FluidLoc cable
05 CSA, ATEX, IECEx Approvals
3300 XL Standard Extension Cable
3300 XL 8 mm Proximity Probes
330101 3300 XL 8 mm Probe
3/8-24 UNFthread, without armor
Minimum unthreaded length: 3.0 in
Minimum case length: 4.9 in
10 1.0 meter (3.3 feet)
12 Miniature coaxial ClickLocconnector
FluidLoc cable
05 CSA, ATEX, IECEx Approvals
3300 XL 8 mm Reverse Mount Probes
330105-02-12-CC-DD-EE3/8-24 UNF threads
15 1.5 meter (4.9 feet)
02 Miniature ClickLoc coaxialconnector
05 CSA, ATEX, IECEx Approvals
3300 XL 8 mm Reverse Mount Probes
Proximity ProbeHousing Assemblies
28 3300 XL 8mm probe
selectablehazardous area approvals
05 0.5 m (20 in)
4.1 in (94 mm) = 041
03One 3/4-14 NPT plug
One 3/4-14 to 1/2-14 NPT reducer
One cable seal grip with grommets for
the following cable sizes:
• 1/8 to 3/16 inches
• 1/4 to 5/16 inches
• 5/16 to 3/8 inches
023/4-14 NPT
3300 XL 50 mm Proximity Probe
0 1 ½-20 Thread
9 09.0 meters (29.5 feet)
0 0High Temperature FluidLocCable
0 0 No Approvals
3300 XL 11 mm Proximity Probes
330703 3300 XL 11 mm Probe
M14 x 1.5 thread,without armor
Minimum unthreaded length:0 mm
Minimum length:100 mm
10 1.0 meter (3.3 feet)
01Miniature coaxial ClickLocconnector
with connectorprotector, standard cable
PROXPAC XL Proximity TransducerAssembly
Operating Voltage:-18 to -26V DC
Current Consumption:2-12mA
Output Signal:-1 to -20V DC
Sensitivity:200mV/mil (7.87V/mm) ±5%
Frequency Response:0 to 10kHz (-3dB)
Measurement Range:0.25 to 2.5mm
Linear Range :0.5 to 2.0mm
Resolution:1μm (0.04 mils)
Temperature Drift:±0.1%/°C
Digital electronic module
Digital electronic module with four outputs
Output current 2 A per output
Rated load voltage 24 VDC
Short-circuit protection
Suitable for solenoid valves
DC contactors, and indicator lights
Extended temperature range
from 0 to 55° C with vertical installation
Electronics module
SIMATIC DP
ELECTRONIC MODULE FOR ET200S
2 AI STAND. I-4DMU 15 MM WIDE
+/-20MA; 13 BIT +SIGN,4 .. 20MA
12 BIT FOR 4-WIRE TRANSDUCER
CYCLE TIME65 MS/CHANNEL
WITH LED SF (GROUP FAULT)
Electronics module
SIMATIC DP
Electronics module for ET 200S
2 AI TC standard
15 mm width
15 bit+sign +/-80 mV
Characteristic linearization for
thermocouples of the types: B, E, J, K, L, N, R, S, T Cycle
time 65 ms/channel
with SF LED (group fault)
Electronics module
SIMATIC DP
ELECTRONIC MODULE FOR ET200S
2 AI TC 15 MM WIDE
15 BIT + SIGN +/-80MV
CHARACTERISTICS LINEARIZATION FOR
THERMOELEMENTSOF: B, E, J, K, L, N, R, S, T TYPES
CYCLE TIME 65 MS/CHANNEL
WITH LED SF (GROUP FAULT)
SIMATIC DP, Electronics module
SIMATIC DP
ELECTRON. MODULE F
ET200S, 4/8 F-DIPROFISAFE
24V DC, 30 MM
WIDTH UP TO CATEGORY 4(EN954-1)
ALSO USEABLE IN PROFINET- NETWORK
WITHIM151-3 HF
Analog Signal Multiplier
Power Supply:24V DC (±10%)
Power Consumption:3.5W
Input Signals:2× (0-10V or 4-20mA)
Output Signal:0-10V or 4-20mA
Input Impedance:1MΩ (voltage), 250Ω (current)
Isolation:1500V AC
Splitter Board
Input Voltage:24V DC (±10%)
Power Consumption:2W max
Isolation Voltage:1500V AC
Input Channels:4 (configurable)
Output Channels:8 (1:2 splitting ratio)
Signal Types:4-20mA, 0-10V, digital
Exciter Control Module
Power Supply:110/220V AC ±10% or 24/48V DC
Power Consumption:50W (max)
Field Voltage :0-300V DC (adjustable)
Field Current:0-20A DC (continuous)
Control Accuracy:±0.25% of setpoint
Response Time:<10ms
Voltage Regulation:±0.5% of nominal
Frequency Range:40-70 Hz
Stability:<0.1% oscillation
Harmonic Distortion:<1% THD
Processor Unit Relay Card
Operating Voltage: 24V DC
Power Consumption: ≤5W
Isolation: 2.5kV AC
Processor: 32-bit DSP
Memory:64MB Flash
Mounting Equipment, 130mm
Mounting kit for SIPART PS2
Schwenkantriebe nachVDI/VDE 3845 (Namur)
Kupplungsrad aus Kunsttoff
Mounting Equipment, 130mm
Copyright Notice © 2004-2024 amikong.com All rights reserved
Disclaimer: We are not an authorized distributor or distributor of the product manufacturer of this website, The product may have older date codes or be an older series than that available direct from the factory or authorized dealers. Because our company is not an authorized distributor of this product, the Original Manufacturer’s warranty does not apply.While many DCS PLC products will have firmware already installed, Our company makes no representation as to whether a DSC PLC product will or will not have firmware and, if it does have firmware, whether the firmware is the revision level that you need for your application. Our company also makes no representations as to your ability or right to download or otherwise obtain firmware for the product from our company, its distributors, or any other source. Our company also makes no representations as to your right to install any such firmware on the product. Our company will not obtain or supply firmware on your behalf. It is your obligation to comply with the terms of any End-User License Agreement or similar document related to obtaining or installing firmware.