We offer a comprehensive range of Invensys automation solutions, focusing on core systems from its flagship brands:
Foxboro(I/A Series Distributed Control System)
Triconex(Tricon CX and Trident (Emergency Stop System))
Whether you need components for a specific platform (such as the Foxboro I/A Series or Triconex safety system) or need to source replacement/discontinued parts based on device functionality, inquiry us now
We are committed to sourcing the mission-critical Invensys products you need.
We offer a comprehensive range of Invensys automation solutions, focusing on core systems from its flagship brands:
Foxboro(I/A Series Distributed Control System)
Triconex(Tricon CX and Trident (Emergency Stop System))
Whether you need components for a specific platform (such as the Foxboro I/A Series or Triconex safety system) or need to source replacement/discontinued parts based on device functionality, inquiry us now
We are committed to sourcing the mission-critical Invensys products you need.
Communication Protocol:Modbus TCP/IP, DeviceNet
Data Rate:Up to 1 Mbps
Power Consumption:L ess than 4W
Operating Temperature:-40C to +70°C
Mounting Type:Panel Mount
Power consumption: Typically 15-30W
Operates on 24V DC
Operating Temperature: 0°C to +60°C
Storage Temperature: -40°C to +85°C
Humidity: 5% to 95% non-condensing
Points:32, commoned
Nominal input current:4–20 mA DC
Operational current range:2–22 mA DC
Absolute maximum field voltage:33 V DC
Absolute maximum input current:50 mA DC
Input bandwidth (3dB):16 Hz
Source impedance:180 Ω
Resolution:12 bits
Absolute error:0.15% of full scale (20 mA)
Diagnostic:Force-to-value diagnostic (FVD)
Scan time:<1 ms for all 32 points
Rated Voltage: 24V DC or 120V AC
Current Rating:1-10A
Wire Size Compatibility: 12 AWG to 24 AWG
Operating Temperature Range: -10°C to +60°C
Storage Temperature Range: -20°C to +70°C
Input Type: Dry contact or Wet contact inputs
Wet contact inputs: Typically 24V DC
Power Supply: 24V DC ± 20%
Power Consumption: Approximately 3W
Maximum Power Consumption: 3 watts
Operating Temperature Range: -40°C to +70°C
Storage Temperature Range: -40°C to +85°C
Relative Humidity: 5% to 95%, non-condensing
Points:16, commoned
Nominal output voltage:24 V DC
Operational voltage range:15–30 V DC
Absolute maximum output voltage:33 V DC
Absolute maximum reverse input voltage:–0.6 V DC
Leakage to load (Off-state):<1 mA
On-state voltage drop:<1 V DC @ 1.5 A
Loop-back scan time:<1 ms for all 16 points
Wide range of AC and DC input voltages
Power factor correction
Dual stage current limiting
Overvoltage shut down circuitry
Transformer isolated 24 V DC output
Class 1, DIV 2, Zone 2 applications
G3 rating for harsh environments
Power for external field devices
Convection cooling (no fans)
Gasketed and sealed housing
Horizontal or vertical DIN rail mounting
Holes for bracket or wall mounting
Relay (form C) status alarm output
Analog Input: 1–5V DC, 4–20 mA
Analog Output: 4–20 mA or 0–10V DC
Voltage: 120/240V AC ±10% (50/60 Hz)
Power Consumption: 5W typical
Operating Temperature: -20°C to +60°C (-4°F to +140°F)
Humidity: 0–95% non-condensing