Safe active/passive digital input FTA
Safe active/passive digital input FTA
115 V AC/DC, 16 channels
Field termination assembly module
16-channel safe input converter module
universalfor both 115 V AC and/or 115 V DC
All inputs are galvanically isolated
Safe current-limited digital input
Safe active/passive digital input FTA
115 V AC/DC, 16 channels
Field termination assembly module
16-channel safe input converter module
universalfor both 115 V AC and/or 115 V DC
All inputs are galvanically isolated
Safe current-limited digital input
Safe current-limited digital input FTA
24 V DC, 16 channels
Sixteen channels
eight channels with a 250 mA
canbe connected to the TSDI-1624C module
via a system interconnection cable (SICC-0001/Lx)
This cable isplugged into
the SIC connector on the FTA module
and connects to a (redundant pair of) SDI-1624module(s)
Safe digital output module
Safe digital output module
110 V DC, 0.32 A, 4 channels
Ability to de-energizel
Ability to de-energize via secondary meansl
Crosstalk between outputsl
Functioning of the suppression diodes
Safe digital output module
Safe digital output module
110 V DC, 0.32 A, 4 channels
Ability to de-energizel
Ability to de-energize via secondary meansl
Crosstalk between outputsl
Functioning of the suppression diodes
Safe loop-monitored digital output module
Safe loop-monitored digital output module
48 V DC, 500mA, 4 channels
Ability to de-energize
Ability to de-energize via secondary means
Cross talk between outputsl
Function of the suppression diodes
Lead breakage in the (external) output wiring
Short circuit of the outputs
Safe loop-monitored digital output module
Safe loop-monitored digital output module
48 V DC, 500mA, 4 channels
Ability to de-energize
Ability to de-energize via secondary means
Cross talk between outputsl
Function of the suppression diodes
Lead breakage in the (external) output wiring
Short circuit of the outputs
Safe digital output module
Safe digital output module
48 V DC, 0.75 A, 4 channels
Ability to de-energizel
Ability to de-energize via secondary meansl
Crosstalk between outputsl
Functioning of the suppression diodes
Safe digital output module
Safe digital output module
48 V DC, 0.75 A, 4 channels
Ability to de-energizel
Ability to de-energize via secondary meansl
Crosstalk between outputsl
Functioning of the suppression diodes
Safe digital input module
Safe digital input module
48 Vdc, 16 channels
Ability to receive logic level ‘0’ signals
Ability to receive logic level ‘1’ signals
Crosstalk between inputs
Safe digital input module
Safe digital input module
48 Vdc, 16 channels
Ability to receive logic level ‘0’ signals
Ability to receive logic level ‘1’ signals
Crosstalk between inputs
Safe loop-monitored digital output module
Safe loop-monitored digital output module
24 Vdc, 1 A, 4 channels
Ability to de-energize
Ability to de-energize via secondary means
Cross talk between outputs
Function of the suppression diodes
Lead breakage in the (external) output wiring
Short circuit of the outputs
Safe digital output module
Safe digital output module
24 Vdc, 2 A, 4 channels
Ability to de-energize the output
Ability to de-energize the group
(via secondary means)
Crosstalk between outputs, and
Functioning of the suppression diodes
Safe digital output module
Safe digital output module
24 Vdc, 2 A, 4 channels
Ability to de-energize the output
Ability to de-energize the group
(via secondary means)
Crosstalk between outputs, and
Functioning of the suppression diodes
Analog output module
Space requirements: 4 TE, 3 HE (= 4 HP, 3U)
Power requirements: 5 V DC, 30 mA
Number of outputchannels:2
Output specification(mA):Active or passive, 0-20 / 4-20 mA
D/A converter: 12-bit
Off current: < 0.05 mA
Maximum loadcapacitance:100 nF
WDG input current: 0.5 mA
Safe analog output module
0(4)—20 mA, 2 channels
Correct output value
(current value ± 5%)
Ability to de-energize
Cross talk between analog outputs
igital input module
DIGITAL INPUT MODULE
LINE MONITORED W/ FAULT MONITOR
16 CHANNELS
Functional tests of the various trip levels applied
Channel independence
Monitoring of supply voltage to input devices
Earth connection
Used supply voltages
Digital input module
DIGITAL INPUT MODULE
LINE MONITORED W/ FAULT MONITOR
16 CHANNELS
Functional tests of the various trip levels applied
Channel independence
Monitoring of supply voltage to input devices
Earth connection
Used supply voltages
ANALOG INPUT MODULE
ANALOG INPUT MODULE
24VDC
16 CHANNEL
Absolute accuracy
Correct conversion over the full range
Crosstalk between inputs
Channel input filters
Internal supply voltages
ANALOG INPUT MODULE
ANALOG INPUT MODULE
24VDC
16 CHANNEL
Absolute accuracy
Correct conversion over the full range
Crosstalk between inputs
Channel input filters
Internal supply voltages
Safe analog input module
Safe digital input module
Absolute accuracy
Correct conversion over full range
Cross talk between inputs
Output voltage of the 26 Vdc outputs
Safe analog input module
Safe digital input module
Absolute accuracy
Correct conversion over full range
Cross talk between inputs
Output voltage of the 26 Vdc outputs
Safe digital input module (24 Vdc, 16 channels)
DIGITAL INPUT MODULE
24VDC
16 CHANNEL
Safe digital input module
Power Supply Unit
Power Supply Unit
24/5 Vdc, 16A
dual 5 V supply (out of 24 VDC) for
Control Processor and redundant IO
non-redundant IO
Battery and Key switch Module
backup batteries for CP1 and CP2
Reset key switch
Force Enable key switch
three general purpose inputs (24 VDC)

Copyright Notice © 2004-2024 amikong.com All rights reserved
Disclaimer: We are not an authorized distributor or distributor of the product manufacturer of this website, The product may have older date codes or be an older series than that available direct from the factory or authorized dealers. Because our company is not an authorized distributor of this product, the Original Manufacturer’s warranty does not apply.While many DCS PLC products will have firmware already installed, Our company makes no representation as to whether a DSC PLC product will or will not have firmware and, if it does have firmware, whether the firmware is the revision level that you need for your application. Our company also makes no representations as to your ability or right to download or otherwise obtain firmware for the product from our company, its distributors, or any other source. Our company also makes no representations as to your right to install any such firmware on the product. Our company will not obtain or supply firmware on your behalf. It is your obligation to comply with the terms of any End-User License Agreement or similar document related to obtaining or installing firmware.