Kindly Reminder
Can't Find Your Required Components?
If your specific control system parts are not listed on our website, contact us immediately.
Our procurement specialists will source genuine new components tailored to your technical requirements.
All Amikon-supplied automation parts include:
12 Months Warranty
24h /7 online Service ( info@amikon.cn | +86 18020776786 )
Original new Factory Sealed
Kindly Reminder
Can't Find Your Required Components?
If your specific control system parts are not listed on our website, contact us immediately.
Our procurement specialists will source genuine new components tailored to your technical requirements.
All Amikon-supplied automation parts include:
12 Months Warranty
24h /7 online Service ( info@amikon.cn | +86 18020776786 )
Original new Factory Sealed
Frequency Converter Drive Board
PROFIBUS/MPI or PROFINET
Control Voltage: 24 V DC (±15%)
Output Switching Frequency: 1–16 kHz
Isolation Voltage: ≥2.5 kV AC
Operational Temperature: 0°C to +50°C
Inverter control board
Control Voltage: +24 V DC
Switching Frequency: 5 kHz–15 kHz
Output Pulses: ≥8 PWM
Digital: Start/stop, fault reset
Analog: ±10 V
Operating Temperature: –10°C to +50°C
Inverter control board
Inverter control board
IGD9 for devices 510-620 V DC
1300 A
Logic Supply Voltage: +24 V DC (±10%)
DIP Switches:0–10 V, 4–20 mA
Operating Temperature: 0°C to +40°C
Humidity: ≤95% (non-condensing)
INVERTER DRIVE TRIGGER BOARD
Control Voltage: 24 V DC (±10%)
Isolation Voltage: ≤2.5 kV AC
Output Frequency: ≤20 kHz
Max Output Current: 3–5 A
Signal Logic: 0–24 V DC control signals
Operating Temperature: –10°C to +55°C
Storage Temperature: –40°C to +85°C
Relative Humidity: ≤93% (non-condensing)
Frequency converter trigger driver board
Logic Circuit: 24 V DC
Isolation Voltage: ≥2.5 kV AC
Output Current: Up to 2–3 A
Frequency Range: 1 kHz–20 kHz
Operating Temperature: 0°C to +60°C
Humidity: ≤95% (non-condensing)
OPERATOR PANEL
OPERATOR PANEL
PMU
PARAMETER ASSIGNMENT UNIT
FOR DESIGNS C / D
SIMOVERT MASTERDRIVES
Power supply module
PSU2 Power Board
Power supply module
Nominal Voltage: 400 VAC
Input Range: 380 VAC – 480 VAC
Frequency: 45–65 Hz
Output Voltage: 24 VDC
Output Current: Typically 10 A
Power Rating: 240 W
Thermal sensor
Thermal sensor
THERMAL DETECTOR
FOR ACQUISITION OF HEAT SINK TEMPERATURE
Operating Range: -25°C to +150°C
Accuracy:±1.5°C
Response Time:<1 second
Operating Voltage: 24 VDC
Shock/Vibration Resistance: 5–100 Hz
Inverter control module
SIMOVERT MASTERDRIVES
Inverter control module
IGD2 for devices 660-690 V AC 3
50/60 Hz and 890-930 V DC
60 A and 82 A
Normalizing module
Normalizing module
ABO for devices 660-690 V
3 AC and 890-930 V DC
82 A
Input Voltage (DC Link): 890–930 V DC
Rated Braking Current: 82 A continuous
Compatible AC Line Voltage Range: 660–690 V
Mains Connection Terminals: 3-phase AC supply
Inverter Board
Siemens MM440 Inverter
Voltage Range: 3-phase 380–480V AC (±10%)
Current Rating:up to 200A
Power Output: 0.37 kW to 250 kW
Switching Frequency: 2–16 kHz
Communication Interfaces: 0–10V, 4–20mA
Allocation board
allocation board
with functional safety A5E42928536
Supply Voltage: 24V DC (±15%)
Power Consumption: ≤5W
Operating Current per Channel: 100 mA
Isolation Voltage: 500V AC
Operating Temperature: -20°C to +60°C
Relative Humidity: ≤95%
CompactFlash card
SINAMICS S120
CompactFlash card
with firmware option performance expansion
including licensing (Certificate of License) V4.4
Communication components
A5E00242932
SIMATIC S7-300
PROFIBUS DP/MPI
PROFIBUS D-Sub 9-pin
Up to 12 Mbps for PROFIBUS
AC/DC DRIVE MODULE
AC/DC DRIVE
SIMOVERT MASTERDRIVES
890-930 V DC INPUT
660-690 V AC OUTPUT
3 PH
23 KW
1200 AMP
IP00
INTERFACE BOARD
INTERFACE BOARD
TERMINAL BLOCK SE300
FOR TECHNOLOGY MODULE T300
SIMOVERT MASTERDRIVES
Double Motor Module
SINAMICS S120
Double Motor Module
input: 600 V DC
output: 400V 3AC, 18 A/18 A
design: booksize D type
internal air cooling optimized pulse patterns
and support of the extended Safety Integrated
functions incl. DRIVE-CLiQ cable
Inverter driver board
SINAMICS S120/S150
Logic-side (control): 24 V DC
Power-side (IGBT control):up to 800 V DC peak
Signal Isolation: ≥2500 V AC
Operating: 0°C to +55°C
Storage: -40°C to +85°C
BRAKING RESISTOR
BRAKING RESISTOR
SINAMICS
160 OHM
4 KW
460 V
FOR POWER MODULE
FSB BASE MOUNTING POSSIBLE
SINGLE MOTOR MODULE
SINAMICS S120
SINGLE MOTOR MODULE
INPUT: DC 600V
OUTPUT: 3-PH 400V, 9A
FRAME SIZE: BOOKSIZE D-TYPE
INTERNAL AIR COOLING OPTIMIZED PULSE
SAMPLE AND SUPPORT OF THE EXTENDED
SAFETY INTEGRATED FUNCTIONS
INCL. DRIVE-CLIQ CABLE
SINGLE MOTOR MODULE
SINAMICS S120
SINGLE MOTOR MODULE
INPUT: DC 600V
OUTPUT: 3AC 400V,
30A FRAME SIZE: BOOKSIZE C-TYPE
INTERNAL AIR COOLING OPTIMIZED
PULSE SAMPLE AND SUPPORT OF
THE EXTENDED SAFETY INTEGRATED FUNCTIONS
INCL. DRIVE-CLIQ CABLE
INVERTER CUVP BOARD
INVERTER CUVP BOARD
Logic Supply Voltage:24V DC ±10%
Multi-core DSP/Vector processor
Temperature Range:0°C to +55°C
EnDAT 2.2, Hiperface DSL¹, TTL/HTL²
SINAMICS S120 FW ≥ V4.8
Control Module
SINAMICS S
spare part
Pre-charging resistor 4R0
Resistance Value: 4Ω (4.0 Ohms)
Resistance:Ω (4.0 Ohms) ±10% tolerance
Power Rating:500 W to 1500 W
Control Board
Input Power: 24V DC
Sensor Interfaces: Analog I/O (0-10V/4-20mA)
ARM/X86-based chipsets
Temperature Range: -20°C to +60°C
Humidity Tolerance: ≤95% (non-condensing)
POWER SUPPLY UNIT
POWER SUPPLY UNIT
CIM PM-IF
SINAMICS spare part
CIM PM-IF for Power Module
PM 240 FSGX CIB,
power supply board and mounting plate
Capacitor board
SINAMICS S120
Adapter cable 4-pole
for connection of the connector X41
for replacement of the CIB module
with a Control Interface Module (CIM)
is only required for air-cooled Power Modules
LINE REACTOR
SINAMICS LINE REACTOR
FOR 10 KW SMART LINE MODULE
INPUT: 3-PH 380-480 V
50/60 HZ
Power Block Drive Board
Power Block Drive Board
DC Link Voltage: 510–720 V DC
AC Output Voltage:400 V AC
Continuous Output: Up to 100–280 A (rms)
Cooling Method: Liquid or forced-air cooling
Thermal Resistance: < 0.05 K/W
TM120 TERMINAL MODULE
SINAMICS TERMINAL MODULE
CABINET TM120
WITHOUT DRIVE-CLIQ CABLE ADD ON BOARD
FOR SINAMICS CONVERTERS
PTC and KTY analog inputs
with safe electrical isolation
Single Motor Module
SINAMICS S120
Single Motor Module
input: 600 V DC
output: 400 V 3 AC,
9 A type of construction: booksize
internal air cooling optimized pulse patterns
and support of the extended Safety
Integrated functions incl. DRIVE-CLiQ cable
BRAKING MODULE
SINAMICS BRAKING MODULE
INPUT: 1035 V DC
OUTPUT: 250 KW/15 S
FOR CHASSIS UNITS
HX AND JX
PC Adapter
SIMATIC S7
PC ADAPTER V5.1
FOR CONNECTION OF S7-300/400
C7, M7; FOR CONVERSION OF RS232 TO RS485
W/O RS232 CABLE
INTERFACE ADAPTER
INTERFACE ADAPTER
DOUBLE PTP1
PEER TO PEER
FOR 12 PULSE OPERATION
SIMOVERT MASTERDRIVES
MOTION CONTROL BOARD
CLOSED-LOOP AND CONTROL MODULE
MOTION CONTROL BOARD
CUMC
60 MHZ
SIMOVERT MASTERDRIVES
Control Interface Board
SINAMICS S
replacement Control Interface Board
for 380-480V 3AC
50/60 Hz
820A basic line module
IPI Parallel Switch Module
Parallel switch module IPI
Input Voltage:three-phase systems
Rated Voltage:380–480V AC (±10% tolerance)
Switching Capability: 5–6 inverters
SINAMICS S120 Smart Line Module
SINAMICS S120
Smart Line Module
380-480V 3AC, 50/60 Hz
Output: 510-650 V DC, 550 A
Rated power: 250kW
Built-in unit IP00 Internal air cooling
Drive-CLiQ cable
Rectifier interfaces Module
Rectifier interfaces Module
PER2 for infeed
regenerative feedback Supply units
with Designs H and K
380-480 V 3 AC, 50/60 Hz
INVERTER TRIGGERING MODULE
INVERTER TRIGGERING MODULE
IGD1 FOR UNITS
3-PHASE
380-460VAC
50/60 HZ
A. 510-620VDC
186 AMP
Copyright Notice © 2004-2024 amikong.com All rights reserved
Disclaimer: We are not an authorized distributor or distributor of the product manufacturer of this website, The product may have older date codes or be an older series than that available direct from the factory or authorized dealers. Because our company is not an authorized distributor of this product, the Original Manufacturer’s warranty does not apply.While many DCS PLC products will have firmware already installed, Our company makes no representation as to whether a DSC PLC product will or will not have firmware and, if it does have firmware, whether the firmware is the revision level that you need for your application. Our company also makes no representations as to your ability or right to download or otherwise obtain firmware for the product from our company, its distributors, or any other source. Our company also makes no representations as to your right to install any such firmware on the product. Our company will not obtain or supply firmware on your behalf. It is your obligation to comply with the terms of any End-User License Agreement or similar document related to obtaining or installing firmware.