Allocation Board
painted with functional safety
A5E43710360
Signal Voltage:+15V / –15V
Max Analog I/O Levels:±10V DC
±10V DC :24V
Resolver/Encoder/Tacho: ≤300kHz input
Current Isolation:1.9kV tested rms
Normalizing module
ABI Adaption Board
single/master
Voltage ranges: 380V–600V AC
Operating V Logics Side:24V + 5V DC
Analog I/O Rating:-10 V- +10 V
Power Consumption:15 W max
Operating Humidity:< 95 % Noncon
voltage measurement
CM C98043-A7117-L1
Input Power AC:3‑phase (50‑60 Hz)
DClink Output:400‒610 VDC
Max SCR trigger freq:5kHz
Ambient working:-25°C-+ 55°C
Firing pulse transformer
up to 1000 A DCM
Primary Voltage Range:5–15V DC Pulse
Secondary Output Voltage:20Vpk
Trigger Current Transfer:≥150mA gate trigger output
Signal Rise Time:<0.1μs (typical)
Isolation Voltage:≥4kV AC RMS
Input Voltage:110–230 V AC
Rated Power:Max ~10 W total load
DC Outputs:±15V (±1%)
Control Loop:+24V DC (±5%)
Max Current:+15V: 700 mA†
Voltage Ripple:50 mVpp (20 MHz BW)
Frequency Stability: 50/60 Hz (±3%)
CONTROL BOARD
CPU BOARD
Supply Voltage: 24 V DC (±15%)
Supply Voltage: 24 V DC (±15%)
Signal Inputs: 16 mA
Signal Outputs: 250 mA
Embedded Processor: 150 MHz
330101 3300 XL 8 mm Probe
3/8-24 UNFthread, without armor
Minimum unthreaded length: 1.0 in
Maximum case length: 2.7 in
05 0.5 meter (1.6 feet)
02 Miniature coaxial ClickLocconnector
standard cable
00 Not required
330101 3300 XL 8 mm Probe
3/8-24 UNFthread, without armor
Maximum case length: 2.4 in
05 0.5 meter (1.6 feet)
02 Miniature coaxial ClickLocconnector
standard cable
05 CSA, ATEX, IECEx Approvals
SHIELD FOR I/O AND
COMMUNICATION MODULE 1SLOT
Trusted Shield Single Slot Width
Input Voltage:24V DC
Power Consumption: 8W
Digital Inputs: 16–32 channels
Full Trusted Controller Capability
100-240 Vac Input
Portable wheeled flight case
Simulation of 60 Field Signals
Pre-wired Dual Ethernet (point to point and hub)
Serial Comms wired to terminals
Configured for Companion Slot DI, AI and DO Modules
Model Number: TC-501-02-6M5
Type: I/O SmartSlot Cable
Configuration: Typically used for internal connections
Channels: Supports 40 channels
Termination: Connects Trusted® I/O modules
to FTAs or VFTAs
Communication Protocol:Modbus RTU over RS‑485
Display:128 × 64 pixel LCD
Keypad:5-button navigation
LED Status Bar:Yes (visual feedback)
Power Supply:24 V DC
Operating Temp:–20 °C to +70 °C
Storage Temp:–40 °C to +85 °C
Humidity:0–95 % RH, non-condensing
Galvanic isolation
Open wire detectio
Optional redundancy
Direct / Reverse Input Indication
Supplies Non-incendive field power
Internal or external field power selection
Extensive internal diagnostics for data integrity
Input Voltage:100–240 VAC (universal)
Output Voltage:24 VDC (adjustable up to ~27 V)
Output Current:20 A continuous
Protections:Overcurrent, overvoltage, short-circuit
Operating Temperature Range:–25 °C to +70 °C
Supply voltage: 24 V DC
Reset input voltage: 18 - 70 V DC
Reset input current: 1.1 mA at 24 V DC
Earth fault threshold: 5.5 mA (± 1 mA)
Max. earth current: 25 - 32 mA
Supply voltage: 24 V DC
Reset input voltage: 18 - 70 V DC
Reset input current: 1.1 mA at 24 V DC
Earth fault threshold: 5.5 mA (± 1 mA)
Max. earth current: 25 - 32 mA
Max. output current: 2 A
Isolation 1500 V DC / 1000 V AC
Initial contact resistance: 30 mW
Operating temperature: -5°C-+50°C (23°F-+122°F)
Max. output voltage: 36 V DC / 30 V AC
Power Supply:12–24 V DC
Current Consumption:250 mA @ 24 V DC
Connectivity:Serial (RS‑232);
Mounting:Desk or panel mount with screw terminals
Enclosure Type:Indoor use; IP20 equivalent
Operating Temp:0 °C to +50 °C
Storage Temp:–40 °C to +85 °C
Humidity Limits:Up to 90–95% RH, non-condensing
Space requirements:4 TE, 3 HE (= 4 HP, 3U)
Power requirements: 5 V DC, 160 mA
Number of input channels: 16
Switch level: 1.4-1.9 mA
Hysteresis: 0.2 mA ± 0.05 mA
Input filter: First order, low pass 100Hz
Field wire resistance: Max. 50 Ω
output voltage 7.9-8.7 V
Channels:Typically 16 I/O
Output Types:Digital(0–10 VDC, 4–20 mA)
Analog Resolution:AI: 16‑bit; AO: 13‑bit
Power Supply:24 V DC nominal
Power Isolation:Galvanic isolation, reverse protection
Operating Temp:–40 °C to +70 °C
Enclosure / Rating:Up to IP66
Channels:Typically 16 I/O
Output Types:Analog (0–10 VDC, 4–20 mA)
Analog Resolution:AI: 16‑bit; AO: 13‑bit
Power Supply:24 V DC nominal
Power Isolation:Galvanic isolation, reverse protection
Operating Temp:–40 °C to +70 °C
Enclosure / Rating:Up to IP66
Medium: Multimode Dielectric Fiber 62.5/125
Wavelength:1300 nm
Maximum:Distance 2 km (1 mile)
Connector:MT-RJ
Voltage:3.3 V
Temperature Industrial:-40 C to +85 C (-40 F to +185 F)
Input Voltage Range:85–264 VAC or 120–370 VDC
Input Frequency:47–63 Hz
Output Voltage:24 VDC
Output Current:Up to 16 A
Efficiency:94–95 % at full load
Protection Class:IP20
Operating Temperature:–25 °C to +55 °C
Supply voltage: 24 V DC
Reset input voltage: 18 - 70 V DC
Reset input current: 1.1 mA at 24 V DC
Earth fault threshold: 5.5 mA (± 1 mA)
Max. earth current: 25 - 32 mA
Max. output current: 2 A
Isolation 1500 V DC / 1000 V AC
Initial contact resistance: 30 mW
Operating temperature: -5°C-+50°C (23°F-+122°F)
Max. output voltage: 36 V DC / 30 V AC
330707 3300 XL 11 mm Probe
5/8-18 UNFthread, without armor
20 Minimum case length: 2.0 in
10 1.0 meter (3.3 feet)
12 Miniature coaxial ClickLocconnector
FluidLoc cable
00 Not required
330101 3300 XL 8 mm Probe
3/8-24 UNFthread, without armor
Maximum unthreaded length: 3.8 in
Maximum case length: 4.9in
20 2.0 meters (6.6 feet)
02 Miniature coaxial ClickLocconnector
standard cable
05 CSA, ATEX, IECEx Approvals
330101 3300 XL 8 mm Probe
3/8-24 UNFthread, without armor
Maximum case length: 2.4 in
15 1.5 meter (4.9 feet)
02 Miniature coaxial ClickLocconnector
standard cable
05 CSA, ATEX, IECEx Approvals
330101 3300 XL 8 mm Probe
3/8-24 UNFthread, without armor
Maximum case length: 2.3 in
15 1.5 meter (4.9 feet)
02 Miniature coaxial ClickLocconnector
standard cable
05 CSA, ATEX, IECEx Approvals
16 3300 XL 8 mm probe
00 Probe cable not required
307 Maximum length 30.7 in
0 6One 3/4-14 NPT fitting,
one 3/4-14NPT to 1/2-14 NPT
SST reducerand two plugs
0 23/4-14 NPT
16 3300 XL 8 mm probe
00 Probe cable not required
200 Maximum length 20.0 in
0 6One 3/4-14 NPT fitting,
one 3/4-14NPT to 1/2-14 NPT
SST reducerand two plugs
0 23/4-14 NPT
34 3300 XL 8 mm probe with connectorprotector
selectable hazardous areaapprovals
10 1.0 m (39 in)
20 Minimum length 2.0 in
062 Minimum length 6.2 in
04 One 3/4-14 NPT plug only
02 3/4-14 NPT
34 3300 XL 8 mm probe with connectorprotector
selectable hazardous areaapprovals
10 1.0 m (39 in)
20 Minimum length 2.0 in
058 Minimum length 5.8 in
04 One 3/4-14 NPT plug only
02 3/4-14 NPT
34 3300 XL 8 mm probe with connectorprotector
selectable hazardous areaapprovals
10 1.0 m (39 in)
096 Minimum length 9.6 in
04 One 3/4-14 NPT plug only
02 3/4-14 NPT
34 3300 XL 8 mm probe with connectorprotector
selectable hazardous areaapprovals
10 1.0 m (39 in)
085 Minimum length 8.5 in
04 One 3/4-14 NPT plug only
02 3/4-14 NPT
34 3300 XL 8 mm probe with connectorprotector
selectable hazardous areaapprovals
10 1.0 m (39 in)
066Minimum length 6.6 in
04 One 3/4-14 NPT plug only
02 3/4-14 NPT
34 3300 XL 8 mm probe with connectorprotector
selectable hazardous areaapprovals
05 0.5 m (20 in)
030 Minimum length 3.0 in
03 One 3/4-14 NPT plug
One 3/4-14 to 1/2-14 NPT reducer
One cable seal grip with grommets for
the following cable sizes:
1/8 to 3/16 inches
1/4 to 5/16 inches
5/16 to 3/8 inches
02 3/4-14 NPT
33 3300 XL 8 mm probe
with connectorprotector
05 0.5 m (20 in)
035 Minimum length 3.5 in
03 One 3/4-14 NPT plug
One 3/4-14 to 1/2-14 NPT reducer
One cable seal grip with grommets for
the following cable sizes:
1/8 to 3/16 inches
1/4 to 5/16 inches
5/16 to 3/8 inches
02 3/4-14 NPT
28 3300 XL 8 mm probe
selectablehazardous area approvals
05 0.5 m (20 in)
15 Minimum length 1.5 in (38 mm)
050 Minimum length 5.0 in
03 One 3/4-14 NPT plug
One 3/4-14 to 1/2-14 NPT reducer
One cable seal grip with grommets for
the following cable sizes:
1/8 to 3/16 inches
1/4 to 5/16 inches
02 3/4-14 NPT
28 3300 XL 8 mm probe
selectablehazardous area approvals
05 0.5 m (20 in)
15 Minimum length 1.5 in (38 mm)
028 Minimum length 2.8 in
04 One 3/4-14 NPT plug only
02 3/4-14 NPT
28 3300 XL 8 mm probe
selectablehazardous area approvals
05 0.5 m (20 in)
15 Minimum length 1.5 in (38 mm)
012 Minimum length 1.2 in
04 One 3/4-14 NPT plug only
02 3/4-14 NPT
28 3300 XL 8 mm probe
selectablehazardous area approvals
05 0.5 m (20 in)
061 Minimum length 6.1 in
03 One 3/4-14 NPT plug
One 3/4-14 to 1/2-14 NPT reducer
One cable seal grip with grommets for
the following cable sizes:
1/8 to 3/16 inches
1/4 to 5/16 inches
5/16 to 3/8 inches
02 3/4-14 NPT
28 3300 XL 8 mm probe
selectablehazardous area approvals
05 0.5 m (20 in)
024 Minimum length 2.4 in
03 One 3/4-14 NPT plug
One 3/4-14 to 1/2-14 NPT reducer
One cable seal grip with grommets for
the following cable sizes
1/8 to 3/16 inches
1/4 to 5/16 inches
5/16 to 3/8 inches
02 3/4-14 NPT
27 3300 XL NSv probe
selectablehazardous area approvals
10 1.0 m (39 in)
15 Minimum length 1.5 in (38 mm)
047 Minimum length 4.7 in
03 One 3/4-14 NPT plug
One 3/4-14 to 1/2-14 NPT reducer
One cable seal grip with grommets for
the following cable sizes
1/8 to 3/16 inches
1/4 to 5/16 inches
5/16 to 3/8 inches
02 3/4-14 NPT
16 3300 XL 8 mm probe
10 1.0 m (39 in)
15 Minimum length 1.5 in (38 mm)
075 Minimum length 7.5 in
03 One 3/4-14 NPT plug
One 3/4-14 to 1/2-14 NPT reducer
One cable seal grip with grommets for
the following cable sizes:
1/8 to 3/16 inches
1/4 to 5/16 inches
5/16 to 3/8 inches
02 3/4-14 NPT
16 3300 XL 8 mm probe
10 1.0 m (39 in)
15 Minimum length 1.5 in (38 mm)
071 Minimum length 7.1 in
03 One 3/4-14 NPT plug
One 3/4-14 to 1/2-14 NPT reducer
One cable seal grip with grommets for
the following cable sizes:
1/8 to 3/16 inches
1/4 to 5/16 inches
5/16 to 3/8 inches
02 3/4-14 NPT
16 3300 XL 8 mm probe
10 1.0 m (39 in)
120 Minimum length 12.0 in
03 One 3/4-14 NPT plug
One 3/4-14 to 1/2-14 NPT reducer
One cable seal grip with grommets for
the following cable sizes:
1/8 to 3/16 inches
1/4 to 5/16 inches
5/16 to 3/8 inches
02 3/4-14 NPT
16 3300 XL 8 mm probe
10 1.0 m (39 in)
053Minimum length 5.3in
03 One 3/4-14 NPT plug
One 3/4-14 to 1/2-14 NPT reducer
One cable seal grip with grommets for
the following cable sizes:
1/8 to 3/16 inches
1/4 to 5/16 inches
5/16 to 3/8 inches
02 3/4-14 NPT
16 3300 XL 8 mm probe
05 0.5 m (20 in)
105 Minimum length10.5 in
03 One 3/4-14 NPT plug
One 3/4-14 to 1/2-14 NPT reducer
One cable seal grip with grommets for
the following cable sizes:
1/8 to 3/16 inches
1/4 to 5/16 inches
5/16 to 3/8 inches
02 3/4-14 NPT
16 3300 XL 8 mm probe
05 0.5 m (20 in)
103 Minimum length10.3 in
03 One 3/4-14 NPT plug
One 3/4-14 to 1/2-14 NPT reducer
One cable seal grip with grommets for
the following cable sizes:
1/8 to 3/16 inches
1/4 to 5/16 inches
5/16 to 3/8 inches
02 3/4-14 NPT