SC S300 SAFETY CONTROLLER SIL3
Input Voltage: 24 VDC (±10%)
Output Voltage: 24 VDC
Current Capacity: Typically up to 5A
Operating Temperature: -40°C to +70°C (-40°F to +158°F).
Humidity: 5–95% non-condensing
SC S300 SAFETY CONTROLLER SIL3
Digital Inputs:24 VDC
Cycle Time: <10 ms
Operating Temperature: -20°C to +60°C (-4°F to +140°F)
Contact Rating: 5A @ 250VAC
Operating Force: 1.8N minimum
Release Force: 0.1N minimum
Pre-travel: 1.5mm maximum
DeltaV 8-Port Ethernet Switch
Copper Ports: 6 × 10/100/1000Base-T RJ45
Fiber Ports: 2 × 100/1000Base-X SFP
Total Ports: 8 ports
Input Voltage: 24 VDC
Power Consumption: Typically <15W
Switching Capacity: 16 Gbps
Packet Forwarding Rate: 11.9 Mpps.
MAC Address Table: 8K entries.
Jumbo Frames: Support up to 9.6 kB
HVD BOARD
Voltage Rating: 3.3 kV, 6.6 kV
Control Voltage: 24 VDC
Power Consumption: <20 W
Operating Temperature: 0°C to +55°C
Humidity: Up to 95% RH (non-condensing)
CPU module
Series:RX3i PacSystem
Part Number:IC695CPE330-AFAT
Product Type:CPU module
Processor Clock Speed:1.0 Ghz
RAM:64 MB
NVRAM:64MB
I/O Points:up to 32 K I/O
Controller Redundancy:Supported
Maximum Program Blocks:512
Maximum Block Size:128 kilobytes
SAFETY CENTRAL MODULE
Use in the PES H41q-MS, -HS, -HRS
Safety-related, applicable
up to SIL 3 according to IEC 61508
Microprocessors INTEL 386EX, 32 bits
Clock frequency 25 MHz
Data SRAM 1 MB
Space requirement 8 SU
Operating data 5 V / 2 A
Analog Output Module
S-Series AO 4-20 mA HART 8-Channel
Local Bus Power 12 VDC at 150 mA
Bussed Field Power 24 VDC at 300 mA
Field Circuit24 VDC at 23 mA/Channel
Ambient Temperature -40°C to +70°C
Shock 10g ½ Sinewave for 11msec
Vibration 1mm Peak to Peak from 2 to 13.2Hz
0.7g from 13.2 to 150Hz
AirborneContaminantsISA-S71.04 –1985 Airborne
Contaminants Class G3
Analog Output Module
S-Series AO 4-20 mA HART 8-Channel
Local Bus Power 12 VDC at 150 mA
Bussed Field Power 24 VDC at 300 mA
Field Circuit24 VDC at 23 mA/Channel
Ambient Temperature -40°C to +70°C
Shock 10g ½ Sinewave for 11msec
Vibration 1mm Peak to Peak from 2 to 13.2Hz
0.7g from 13.2 to 150Hz
AirborneContaminantsISA-S71.04 –1985 Airborne
Contaminants Class G3
32 Channel Terminal Block
Input Power Rating 30 VDC @ 1 A
AmbientTemperature-40 °C to +70 °C
Shock 10 g half-sine wave for 11 ms
Vibration 1 mm peak to peak from 2 to 13.2 Hz
0.7 g from 13.2 to 150 Hz
AirborneContaminantsISA-S71.04 –1985 Airborne
Contaminants Class G3
Relative Humidity 5 to 95% non-condensing
Analog Input Module
ANALOG MODULE
2 WIRE/16CHANNEL
4-20MA
SERIES 2
LOCALBUS POWER RATING: 12VDC AT 150MA
BUSSED FIELD POWER RATING: 24VDC AT 600MA
FIELD CIRCUIT RATING: 240VDC AT 30MA
RACK MOUNTED
Redundant H1 Terminal Block
I/O Count 20 points
Input Type:120V ac
Analog Circuits:4 Inputs, 1 Output
Protocol:DF1
Safety Feature:Master Control Relay
Digital Outputs:8 Contact Outputs
No. of Discrete Inputs:Twelve (12)
Input Voltage Type:120 Volts AC
Voltage Range:79-132 Volts AC
Output Type:Eight (8) Relay
Redundant H1 Terminal Block
Input Power Rating 35 VDC @ 500m A
AmbientTemperature-40 °C to +70 °C
Shock 10 g half-sine wave for 11 ms
Vibration 1 mm peak to peak from 2 to 13.2 Hz
0.7 g from 13.2 to 150 Hz
AirborneContaminantsISA-S71.04 –1985 Airborne
Contaminants Class G3
Relative Humidity 5 to 95% non-condensing
Fieldbus H1 Card
Local Bus Power 12 VDC at 300 mA
Fieldbus Power 9 to 32 VDC at 12 mA/Port
AmbientTemperature-40°C to +70°C
Shock 10g ½ Sinewave for 11msec
Vibration 1mm Peak to Peak from 2 to 13.2Hz;0.7g from 13.2 to 150Hz
AirborneContaminantsISA-S71.04 –1985 AirborneContaminants Class G3
Relative Humidity 5 to 95% Non-Condensing IP 20 Rating
Terminal Block keyPosition D6
Interface Terminal Block
Field Power 35 VDC at 1 A
AmbientTemperature-40°C to +70°C
Shock 10g ½ Sinewave for 11msec
Vibration 1mm Peak to Peak from 2 to 13.2Hz;0.7g from 13.2 to 150Hz
AirborneContaminantsISA-S71.04 –1985 AirborneContaminants Class G3
Relative Humidity 5 to 95% Non-Condensing
Terminal Block Key Position Set according to I/O card installed
Serial Interface Module
SERIAL INTERFACE CARD
12 VDC
300 MA
2 PORT
D4 TERMINAL BLOCK KEY POSITION
Simplex SIC (Serial Interface Card),
LocalBus Power Rating 12 VDC 300mA
Ambient Temperature -40 to 70 degrees C
ADAPT Aeroderivative Monitor
Displacement: 0–500 µm peak-to-peak
Velocity: 0–20 mm/s RMS
Acceleration: 0–50 g peak
Frequency Response: 0.5 Hz to 30 kHz
Sampling Rate: Up to 100 kHz
Operating Temperature: -40°C to +85°C
Wind Turbine Monitor
Vibration Velocity: Typical range 0–20 mm/s RMS
Vibration Acceleration: 0–50 g peak
Frequency Range: 0.5 Hz to 10 kHz
Speed Range: 0–3,000 RPM
Analog Outputs: 4–20 mA
Operating Temperature: -40°C to +85°C
Voltage: 18–30 VDC
Power Consumption: <5 W
Wind Turbine Monitor
Vibration Velocity: Typical range 0–20 mm/s RMS
Vibration Acceleration: 0–50 g peak
Frequency Range: 0.5 Hz to 10 kHz
Speed Range: 0–3,000 RPM
Analog Outputs: 4–20 mA
Operating Temperature: -40°C to +85°C
Voltage: 18–30 VDC
Power Consumption: <5 W
PowerFlex 753 AC drive
Series:PowerFlex 753
Frames:1..5, 8...10
Enclosure Type:AC and DC Input with Precharge
Frames:2 2...7
Enclosure Type 2:IP20/IP00, NEMA/UL Type Open
Voltage:400 Volts AC/540 Volts DC
Horsepower:300
Filtering:Yes
Default CM Cap Connection:Jumper Installed
Frequency drive
PowerFlex 753 AC Drive
with Embedded I/O, Standard Protection
Forced Air, AC Input with DC Terminals
Open Type, 37 Amps, 18.5kW ND
15kW HD, 400 VAC, 3 PH, Frame 3
Filtered, CM jumper installed (preferred)
DB Transistor, Blank (No HIM)
Frequency drive
PowerFlex 753 AC Drive
with Embedded I/O, Standard Protection
Forced Air, AC Input with DC Terminals
Open Type, 30 Amps, 15kW ND, 11kW HD
400 VAC, 3 PH, Frame 3, Filtered
CM jumper installed (preferred)
DB Transistor, Blank (No HIM)
Frequency drive
Part Number/Catalog No.:20F11NC015JA0NNNNN
Series:PowerFlex 753
Frames:1..5,8...10
Enclosure Type:AC & DC Input w/Precharge
Frames:2 2...7
Enclosure Type 2:IP20/IP00, NEMA/UL Type Open
Voltage:400V AC/540V DC
Filtering:Yes
Default CM Cap Connection:Jumper Installed
Copyright Notice © 2004-2024 amikong.com All rights reserved
Disclaimer: We are not an authorized distributor or distributor of the product manufacturer of this website, The product may have older date codes or be an older series than that available direct from the factory or authorized dealers. Because our company is not an authorized distributor of this product, the Original Manufacturer’s warranty does not apply.While many DCS PLC products will have firmware already installed, Our company makes no representation as to whether a DSC PLC product will or will not have firmware and, if it does have firmware, whether the firmware is the revision level that you need for your application. Our company also makes no representations as to your ability or right to download or otherwise obtain firmware for the product from our company, its distributors, or any other source. Our company also makes no representations as to your right to install any such firmware on the product. Our company will not obtain or supply firmware on your behalf. It is your obligation to comply with the terms of any End-User License Agreement or similar document related to obtaining or installing firmware.