3300 XL 8 mm Proximity Probes
330104 3300 XL 8 mm Probe
M10 x 1 thread,with armor
Minimum unthreaded length: 0 mm
Minimum case length: 180 mm
10 1.0 meter (3.3 feet)
01Miniature coaxial ClickLocconnector
with connectorprotector, standard cable
00 Not required
3300 XL 8 mm Proximity Probes
330103 3300 XL 8 mm Probe
M10 x 1 thread,without armor
Minimum unthreaded length: 0 mm
Minimum case length: 20 mm
20 2.0 meters (6.6 feet)
02 Miniature coaxial ClickLocconnector
standard cable
05 CSA, ATEX, IECEx Approvals
3300 NSv Proximity Probes
330903 3300 NSv Probe
M8X1 thread,without armor
Minimum unthreaded length:0 mm
Minimum length: 90 mm
10 1.0 meter (39 in)
02 Miniature coaxial ClickLoc connector
standard cable
05 Multiple Approvals
3300 NSv Proximity Probes
330903 3300 NSv Probe
M8X1 thread,without armor
Minimum unthreaded length:0 mm
Minimum length: 60 mm
10 1.0 meter (39 in)
02 Miniature coaxial ClickLoc connector
standard cable
05 Multiple Approvals
3300 XL Standard Extension Cable
075 7.5 meters (24.6 feet)
02 Standard cable with connectorprotector
05 CSA, ATEX, IECEx Approvals
3300 XL Standard Extension Cable
3300 XL 8 mm Proximity Probes
330104 3300 XL 8 mm Probe
M10 x 1 thread,with armor
Minimum unthreaded length: 0 mm
Minimum case length: 20 mm
15 1.5 meter (4.9 feet)
2 Miniature coaxial ClickLocconnector
FluidLoc cable
05 CSA, ATEX, IECEx Approvals
3300 NSv Proximity Probes
330903 3300 NSv Probe
M8X1 thread,without armor
Minimum unthreaded length:40 mm
Minimum length: 100 mm
10 1.0 meter (39 in)
01Miniature coaxial ClickLoc connector
with connector protector, standardcable
00 Not required
Controller Module
Clock Speed: 800 MHz – 1.5 GHz
RAM: 2 GB DDR4
Operating Voltage: 24 V DC
Power Consumption: ≤18 W
Isolation: ≥3000 V AC
Ethernet Interfaces:2× Gigabit ports
Discrete I/O: 12–24 V DC
Analog Interfaces: 4–8 channels
Motherboard
Input Voltage: 24 V DC
Backplane Power: 5 V DC
RAM Slots: 2× DDR4 SO-DIMM
Storage: Integrated 16 GB flash
Operating: -40°C to +70°C
Humidity: 5–95% non-condensing
MTBF: >250,000 hours
Processor Module
Operating Voltage: 24 V DC
Power Consumption: <12 W
Input Protection:±40 V peak transient
Digital I/O: 16 channels
Analog I/O (Optional): 4 channels
Ethernet: 2× 10/100 Mbps ports
Serial: RS-232/RS-485 for legacy devices
Fieldbus: PROFIBUS DP
Control Board
Operating Voltage: 24 V DC
Power Consumption: ≤15 W
Voltage Range: 0–10 V DC
Resolution: 12-bit
Channels: ≥8 opto-isolated
Input Signal Level: 24 V DC
ADAPTER BOARD
Electrical Rating:24V DC (±10%)
Compatibility:ACS880-04
Communication Ports:RS485
Operation: 0°C to +55°C
Storage: -40°C to +85°C
OUTPUT FILTER BOARD
68295505
System Voltage:380–500V AC
Frequency Range:10–20 kHz
Filter Topology:LC filters (inductors + capacitors)
Operating Temperature:-15°C to +50°C
ACS880 Liquid-Cooled Multi-Drives
VARISTOR UNIT
ACS600 Single Drives
VARISTOR UNIT
Protects ACS600 single drives
Protection DutyAC Input Line Transients
Voltage Rating:380–500V AC (50/60 Hz)
Energy Absorption:≥ 120 joules
Clamping Voltage:1.3–1.5x V
Maximum Continuous Voltage:550 V DC link
PROGRAMMED MODULE
PROGRAMMED
ZINT-571
3AXD50000037997P
Key Function:DCS/SCADA
integrated safety relays
Voltage Supply:24V DC (±10%)
Operating Temp.:-25°C to +60°C
PROGRAMMED MODULE
CCU-24 SP
PROGRAMMED
ZINT-571P
3AXD50000037997P
Key Function:DCS/SCADA
integrated safety relays
Voltage Supply:24V DC (±10%)
Operating Temp.:-25°C to +60°C
CONTROL UNIT
Input Voltage:24V DC (±15%)
Fieldbus: PROFIBUS DP, PROFINET
Digital I/O: ≥16 configurable
Analog I/O: 2x ±10V/4–20mA inputs
Safety I/O: Safe Torque Off
Compatible Drives:ABB ACS880 series
RPBA/PXG01 I/O Boards
Operating Environment:-15°C to +55°C
FIELD SUPPLY BOARD
6RY18030CA05
FIELD SUPPLY
C98043-A7116-L1
SPARE PART
FOR MOTOR CONTROL DC DRIVE
Control Board
PROFIBUS DP
SIMOVERT chassis
Logic Voltage: 24V DC
Analog I/O: ±10V / 4–20mA
Digital I/O: 24V DC terminals
Operating Temp.: 0°C to 55°C
SINGLE MOTOR MODULE
SINAMICS S120
SINGLE MOTOR MODULE
INPUT: DC 600V
OUTPUT: 3AC 400V,
30A FRAME SIZE: BOOKSIZE C-TYPE
INTERNAL AIR COOLING OPTIMIZED
PULSE SAMPLE AND SUPPORT OF
THE EXTENDED SAFETY INTEGRATED FUNCTIONS
INCL. DRIVE-CLIQ CABLE
INVERTER CUVP BOARD
INVERTER CUVP BOARD
Logic Supply Voltage:24V DC ±10%
Multi-core DSP/Vector processor
Temperature Range:0°C to +55°C
EnDAT 2.2, Hiperface DSL¹, TTL/HTL²
SINAMICS S120 FW ≥ V4.8
Control Module
SINAMICS S
spare part
Pre-charging resistor 4R0
Resistance Value: 4Ω (4.0 Ohms)
Resistance:Ω (4.0 Ohms) ±10% tolerance
Power Rating:500 W to 1500 W
Control Board
Input Power: 24V DC
Sensor Interfaces: Analog I/O (0-10V/4-20mA)
ARM/X86-based chipsets
Temperature Range: -20°C to +60°C
Humidity Tolerance: ≤95% (non-condensing)

Copyright Notice © 2004-2024 amikong.com All rights reserved
Disclaimer: We are not an authorized distributor or distributor of the product manufacturer of this website, The product may have older date codes or be an older series than that available direct from the factory or authorized dealers. Because our company is not an authorized distributor of this product, the Original Manufacturer’s warranty does not apply.While many DCS PLC products will have firmware already installed, Our company makes no representation as to whether a DSC PLC product will or will not have firmware and, if it does have firmware, whether the firmware is the revision level that you need for your application. Our company also makes no representations as to your ability or right to download or otherwise obtain firmware for the product from our company, its distributors, or any other source. Our company also makes no representations as to your right to install any such firmware on the product. Our company will not obtain or supply firmware on your behalf. It is your obligation to comply with the terms of any End-User License Agreement or similar document related to obtaining or installing firmware.