ControlLogix 32 Pt 12/24V DC D/I Module
INPUT MODULE
32 POINT
DIGITAL
10-31 VDC
36 PIN
5.5 MA
CONTROLLOGIX
ControlLogix Input Module
1756IB16I
INPUT MODULE
16 POINT
DIGITAL
INDIVIDUALLY ISOLATED
10-30 VDC
36 PIN
Country of Origin: Malaysia
ControlLogix 16 Pt 12/24V DC D/I Module
Input Voltage:12-24 Volts DC Sink
Operating Voltage Range:10-31.2 Volts DC
Module Keying‘:Electronic
10 milliamperes at 31.2 Volts DC
2 milliamperes at 10 Volts DC
5.1 W @ 60 °C (140 °F)
INTERFACE MODULE
1756EN2TR
INTERFACE MODULE
CONTROLLOGIX
CHASSIS MOUNTED
ETHERNET/IP BRIDGE DUAL COPPER
EMBEDDED SWITCH
10/100 MBPS
128 TCP/IP CONNECTIONS
256 CONNECTIONS
ControlLogix Redundant Supply Cable
Series:ControlLogix
Cable Length:3 feet (0.91 meters)
Length:10 feet (3 meters)
Weight:0.64 pounds (0.293 kilograms)
ControlNet Communication Rate:5 megabits-second
Configuration;Redundant
Input Current:970 milliamps at 5.1 Volts DC,
1.7 milliamps at 24 Volts DC
Thermal Dissipation:17.4 BTU per Hour
ControlLogix 17 Slots Chassis
No. of slots:Seventeen (17) slots
Backplane Current @ 1.2VDC:1.5 A
Backplane Current @ 3.3VDC:4A/4 A
Backplane Current @ 5.1VDC:15 A/6 A
Backplane Current @ 24VDC 2.8 A/2.8 A
Orientation:Horizontal
No. of mounting tabs:Ten (10)
Operating Temperature, Series B:0°C to +60°C (+32°F to +140°F)
Operating Temperature, Series C:-25…+60 °C (-13…+140 °F)
Storage Temperature;-40°C to +85°C (-40°F to +185°F)
ControlLogix 10 Slots Chassis
1756A10
CHASSIS
MOUNTING
CONTROLLOGIX
10 SLOTS
20 INCH X 30 INCH X 8 INCH
ControlLogix 7 Slots Chassis
1756A7
CHASSIS
MOUNTING
CONTROLLOGIX
7 SLOTS
20 INCH X 24 INCH X 8 INCH
ControlLogix 4 Slots Chassis
Part Number/Catalog No.1756-A4
Series:ControlLogix
Slots:4
Module Type:Chassis
No. of Slots:Four (4)
Power Dissipation (Max) 4 Watts
Mounting Horizontal
Dimensions:20 x 20 x 8 inches
Weight:1.7 pounds (0.75 kilograms)
Enclosure:Open
Backplane Current (5 Volts DC):10 amps
Backplane Current (24 Volts DC):2.8 Amps
ControlLogix 24V DC Power Supply
1756PB72
POWER SUPPLY
CONTROLLOGIX
STANDARD
18 - 32 VOLT DC INPUT
DC OUTPUT
2.8 AMP
75 WATT
CHASSIS MOUNT
AKA: 96426473
ControlLogix 4 MB Memory Controller
PROCESSOR MODULE
CONTROLLOGIX
LOGIX5562
32 TASKS
100 PROGRAMS PER TASK
RS-232
MAX 250 CONTROLLER CONNECTIONS
4 MB USER MEMORY
478 KB I/O MEMORY
Logix L7SP SIL 3 PLe Safety Partner
Power Dissipation:2.5 W
Series:GuardLogix
Part Number/Catalog No.:1756-L7SP
Module Width:Two (2) Slot
Backplane Current, 5.1VDC:5 mA
Backplane Current, 24VDC:800 mA
Thermal Dissipation:8.5 BTU/hr
Current Draw (1.2 Volts DC):5 milliamps
Current Draw (5.1 Volts):801 milliamps
Thermal Dissipation:8.5 BTU per hour
ControlLogix 8 Point RTD/Thermocouple In
Inputs:8 Isolated Channels
Isolation Voltage:250 Volts Continuous
Module Scan Time:1 ms
Backplane Current at 24 Volts:2 milliamps
Data Format:IEEE 32-bit floating point
Backplane Current (5Volts):250 mA
Backplane Current (24 Volts):150 mA
Power Dissipation (Max):4.6 W
ControlLogix 8 Point A/I Module
1756IF8
I/O MODULE
CONTROLLOGIX
ANALOG INPUT
8 CHANNEL
24 VDC
Country of Origin: United States
ControlLogix Discrete input module
Power Dissipation (Max):6.1 W @ 60 °C (140 °F)
Operating Voltage Range:74-132 VAC
Input Voltage:120 VAC Volts AC
Module Type:Digital DC Input Module
Series:ControlLogix
No. of Inputs:Thirty-Two (32) Inputs
Module Keying:Electronic
Inputs:32
Input Delay Time:Programmable 9 or 18 milliseconds
Minimum Operating Current:5 milliamperes at 74 Volts AC
Maximum Operating Current:10 milliamperes at 132 Volts AC
ControlLogix Input Module
Series:ControlLogix
Inputs:16 Individually Isolated
Module Type:Digital AC Input Module
No. of Inputs:Sixteen (16) Individually Isolated
Input Voltage:120 Volts AC
Operating Voltage Range:79-132 Volts AC
Module Keying:Electronic
ControlLogix 16 Pt D/I 120V AC Module
1756IA16
INPUT MODULE
CONTROLLOGIX
16 POINT
8 POINTS PER GROUP
DIGITAL
74-132 VAC
50/60 HZ
Country of Origin: United States
ControlLogix Enet/IP Fiber Optic Module
1756EN2F
INTERFACE MODULE
CONTROLLOGIX
CHASSIS MOUNTED
ETHERNET/IP BRIDGE FIBER
100 MBPS
128 TCP/IP CONNECTIONS
256 CONNECTIONS
ControlLogix Communication Module
DUAL CHANNEL INTERFACE MODULE
COMMUNICATIONS
CONTROLNET
REDUNDANT MEDIA
5 MBSP
128 LOGIX CONNECTIONS
99 NODES
ControlLogix 8 Pt A/O I or V Module
OUTPUT MODULE
CONTROLLOGIX
ANALOG
8 POINT
SINGLE ENDED OUTPUTS
CURRENT AND VOLTAGE
ControlLogix 16 Point D/O Module
Output Voltage range:10-31.2 VDC
Nominal output voltage:24VDC
Module Keying:Electronic
Outputs:16-Point Electronically Fused
Voltage:12-24 Volts DC
Operating Voltage Range:10-30 Volts DC
Maximum Output Current Rating-Point:1 Amp at 60 Celsius
ControlLogix 16 Pt 24V DC D/O Module
Outputs:16-Point Diagnostic
Voltage:24 Volts DC Source
Operating Voltage Range:19.2-30 Volts DC
Maximum Output Current Rating-Point:2 Amps at
Power Dissipation (Max):3.3 Watts at 60 Celsius
Backplane Current at 5 Volts:250 milliamps
Backplane Current at 24 Volts:140 milliamps

Copyright Notice © 2004-2024 amikong.com All rights reserved
Disclaimer: We are not an authorized distributor or distributor of the product manufacturer of this website, The product may have older date codes or be an older series than that available direct from the factory or authorized dealers. Because our company is not an authorized distributor of this product, the Original Manufacturer’s warranty does not apply.While many DCS PLC products will have firmware already installed, Our company makes no representation as to whether a DSC PLC product will or will not have firmware and, if it does have firmware, whether the firmware is the revision level that you need for your application. Our company also makes no representations as to your ability or right to download or otherwise obtain firmware for the product from our company, its distributors, or any other source. Our company also makes no representations as to your right to install any such firmware on the product. Our company will not obtain or supply firmware on your behalf. It is your obligation to comply with the terms of any End-User License Agreement or similar document related to obtaining or installing firmware.