COOPER Vibration probe
Tip Diameter: 8 mm
Sensitivity: -7.874 mV/µm (-200 mV/mil)
Cable Length: -00100
Linear Range: Typically 2mm
3300 XL 8 mm Proximity Probes
330101 3300 XL 8 mm Probe
3/8-24 UNFthread, without armor
Minimum unthreaded length: 0.0 in
Minimum case length: 3.2 in
10 1.0 meter (3.3 feet)
02 Miniature coaxial ClickLocconnector,
standard cable
00 Not required
Turbine I/O Module
Operating Voltage:24 VDC (±10%)
Power Consumption:12W (typical), 18W (max)
Isolation :1500 VAC (field-to-logic)
MPU Input Impedance:100 kΩ (differential)
Speed Resolution:1 RPM (0.0167 Hz)
Accuracy:±0.02% of reading
Backup Protection I/O Module
Operating Voltage:24 VDC (±10%)
Power Consumption:10W (typical), 15W (max)
Isolation:1500 VAC (field-to-logic)
Backplane Current:5VDC: 1.2A max
Range: 0–250 mV / ±10V (software-selectable)
Resolution: 16-bit
Accuracy: ±0.1% FS
ARCNET Interface I/O Module
ARCNET INTERFACE MODULE
OPTIMIZED FOR MARK VI AND MARK VIE SYSTEMS
Voltage Range: 11–30 VDC (sinking)
Operating Voltage:24 VDC
Isolation:1500 VAC
Touch Panel
SIMATIC HMI MTP1500
Unified Comfort Panel
touch operation
15.6" widescreen
TFT display
16 million colors, PROFINET interface
configurable as of WinCC
Unified Comfort V16
contains open-source software
which is provided free of
charge see enclosed DVD
IGBT MODULE
Voltage Ratings: 1200 V
Nominal Collector Current: 300 A
IGBT: 0.08 K/W
Diode: 0.10 K/W
Gate-Emitter Threshold Voltage : 6 V
Analog Output Module
16-channel Analog Output Field Termination Assembly
Output Type:4-20 mA
Output Channels:16
Output Readback Accuracy:±4%
Output Current Linearity:± 0.05% nominal
Resolution:± 0.05%
Directly Settable Output Current Range:0 mA, 2.9 mA to 21.1 mA
Output Ripple:100 mV peak-to-peak at power line frequency
G5 VAULE CELL 260A
Input Type: 3-phase AC
Output Type: Stabilized DC link voltage
3-phase 380-480V AC (±10%)
Frequency: 47-63Hz
Output Voltage:510-720V DC
Efficiency: >96% at full load
Power Factor: >0.98 (AFE version)
Power unit
Input Type: 3-phase AC
Output Type: Stabilized DC link voltage
3-phase 380-480V AC (±10%)
Frequency: 47-63Hz
Output Voltage:510-720V DC
Efficiency: >96% at full load
Power Factor: >0.98 (AFE version)
High Voltage Inverter Power Unit
Input Type: 3-phase AC
Output Type: Stabilized DC link voltage
3-phase 380-480V AC (±10%)
Frequency: 47-63Hz
Output Voltage:510-720V DC
Efficiency: >96% at full load
Power Factor: >0.98 (AFE version)
GH180 Power Cell 140A
Input Type: 3-phase AC
Output Type: Stabilized DC link voltage
3-phase 380-480V AC (±10%)
Frequency: 47-63Hz
Output Voltage:510-720V DC
Efficiency: >96% at full load
Power Factor: >0.98 (AFE version)
Inverter power supply unit
Input Type: 3-phase AC
Output Type: Stabilized DC link voltage
3-phase 380-480V AC (±10%)
Frequency: 47-63Hz
Output Voltage:510-720V DC
Efficiency: >96% at full load
Power Factor: >0.98 (AFE version)
Inverter power supply unit
Input Type: 3-phase AC
Output Type: Stabilized DC link voltage
3-phase 380-480V AC (±10%)
Frequency: 47-63Hz
Output Voltage:510-720V DC
Efficiency: >96% at full load
Power Factor: >0.98 (AFE version)
Inverter power supply unit
Input Type: 3-phase AC
Output Type: Stabilized DC link voltage
3-phase 380-480V AC (±10%)
Frequency: 47-63Hz
Output Voltage:510-720V DC
Efficiency: >96% at full load
Power Factor: >0.98 (AFE version)
Power unit current
Input Voltage: 690V AC (±10%) 3-phase
Output Voltage: 0-690V AC (per cell)
Power Rating: 1.7 MVA (continuous)
Frequency Range: 0-75 Hz (output)
Efficiency: >98% at full load
Power Factor: >0.95 at full load
BLOWER FANASSEMBLY
SINAMICS/MICROMASTER PX REPLACEMENT FAN
FOR 3AC 380-480 V
50/60 HZ, 260 A
AC DRIVE/POWER/MOTOR MODULES
CHASSIS UNIT FRAMESIZE F
3300 XL 8 mm Proximity Probes
330103 3300 XL 8 mm Probe
M10 x 1 thread,without armor
Minimum unthreaded length: 0 mm
Minimum case length: 20 mm
05 0.5 meter (1.6 feet)
02 Miniature coaxial ClickLocconnector
standard cable
05 CSA, ATEX, IECEx Approvals
3300 XL 8 mm Proximity Probes
330101 3300 XL 8 mm Probe
3/8-24 UNFthread, without armor
Minimum unthreaded length: 0.8 in
Minimum case length: 2.0 in
10 1.0 meter (3.3 feet)
02 Miniature coaxial ClickLocconnector
standard cable
00 Not required
PROXPAC XL Proximity Transducer
2 8 3300 XL 8 mm probe withMultiple Approvals
0 5 50 mm
0 35 30 mm
0 1 One M25 fitting, two plugs
0 23/4-14 NPT
3300 NSv Proximity Probes
330901 3300 NSv Probe,
1/4-28 UNF thread,without armor
Minimum unthreaded length: 0.0 in
Minimum case length: 1.2 in
70 7.0 meters (23.0 feet)
01Miniature coaxial ClickLoc connector
with connector protector, standardcable
05 Multiple Approvals
3300 XL 8 mm Reverse Mount Probes
3300 XL 8 mm Reverse Mount Probes
330105-02-12-CC-DD-EE3/8-24 UNF threads
05 0.5 meter (1.6 feet)
00 Not required
Probe TipMaterial Polyphenylene sulfide
Probe Case Material AISI 303 or 304 stainless steel
Minimum Cable Bend Radius 25.4 mm
Communications Board
Supply Voltage: 24V DC (±10%)
Power Consumption: ≤10W
Isolation:1500V AC
Opto-isolated digital inputs
Robicon Perfect Harmony GH180
Touch operation
SIMATIC HMI
KTP700 SINAMICS
SINAMICS PERFECT HARMONY Key
touch operation
7" TFT display
65536 colors, PROFIBUS interface
contains open-source software
Copyright Notice © 2004-2024 amikong.com All rights reserved
Disclaimer: We are not an authorized distributor or distributor of the product manufacturer of this website, The product may have older date codes or be an older series than that available direct from the factory or authorized dealers. Because our company is not an authorized distributor of this product, the Original Manufacturer’s warranty does not apply.While many DCS PLC products will have firmware already installed, Our company makes no representation as to whether a DSC PLC product will or will not have firmware and, if it does have firmware, whether the firmware is the revision level that you need for your application. Our company also makes no representations as to your ability or right to download or otherwise obtain firmware for the product from our company, its distributors, or any other source. Our company also makes no representations as to your right to install any such firmware on the product. Our company will not obtain or supply firmware on your behalf. It is your obligation to comply with the terms of any End-User License Agreement or similar document related to obtaining or installing firmware.