Power Module
Input Voltage: 3-phase AC
Current Rating: Varies by module
Frequency Range: 0-120Hz
Switching Devices: IGBT
Switching Frequency: 1kHz to 3kHz
Efficiency: >98%
MICROSET INPUT MODULE
Thermocouples:Type J, K, T, etc.
RTDs:Pt100, Pt1000, etc
Analog Voltage:±10V, 0-10V
Analog Current:4-20mA
Resolution: 16-bit or higher
Sampling Rate: Up to 1 kS/s
Accuracy: ±0.1% FS (Full Scale)
MICROSET INPUT MODULE 8 TEMPERATURES
Analog Voltage:0-10V
Current:4-20mA
Input Resolution: 16-bit ADC
Accuracy: ±0.1% FS (Full Scale)
Sampling Rate: 10–100 samples
Thermocouples (Type J, K, T, E, R, S, B, N)
PSU power module
Input Voltage Range:100–240V AC
DC input:24V DC
Output Voltage(s):24V DC
24V Output: 5A–10A
Total Power: 120W–250W
Voltage Regulation: ±1%
Ripple & Noise: <1% of output voltage
MICROSET INPUT MODULE
MICROSET INPUT MODULE 12 DO
Channels: Typically 4-8 differential
Input Range: ±10V, 0-20mA
Resolution: 16-bit
Sampling Rate: Up to 1 MS/s
Isolation:250V AC/DC
Accuracy: ±0.1% FS (full scale)
DIGITAL OUTPUT MODULE
IMI220-418A001: 12 DO 24 VDC 2 A
Number of Outputs: 12 channels
Output Type: 24V DC
Output Voltage: 24V DC
Output Current per Channel: 2A (max)
24 digital inputs module
IMI220-411A001: 24 DI
Model Number: IMI220-411A001
Type: Digital Input Module
Number of Inputs: 24 channels
Input Voltage Range: Typically 24V DC
Input Current per Channel: 5-10 mA
Electric actuator power board
3-Phase AC: 380V–690V AC
Current Rating: 10A peak
DC Bus Voltage: 540V–930V DC
Switching Frequency: 8kHz PWM
Logic Voltage: 24V DC
Electronic card
3-Phase AC: 380V–690V AC
Current Rating: 10A peak
DC Bus Voltage: 540V–930V DC
Switching Frequency: 8kHz PWM
Logic Voltage: 24V DC
Power board
Voltage Range: 50/60Hz
Single-Phase Option: 230V AC
Current Rating: Up to 5A continuous
Inrush Current: ≤20A
Frequency: 0–400Hz
Logic Voltage: 24V DC
Electric actuator power board
Standard: 24V AC/DC ±10%
Optional: 110V AC
Power Consumption: ≤25W
Digital Inputs:24V DC
Analog Inputs:4-20mA / 0-10V
Relays Outputs:5A, 250V AC
Analog Outputs:4-20mA
Electric Actuator Control Panel
Standard: 24V AC/DC ±10%
Optional: 110V AC
Power Consumption: ≤25W
Digital: 24V DC
Electric actuator Economic motherboard
Supply Voltage: 24V AC/DC ±10%
Power Consumption: <15W typical
Digital inputs:24V DC
Analog inputs:4-20mA/0-10V optional
Proximity Probe HousingAssemblies
Proximity Probe HousingAssemblies
00 Probe not required
00 Probe cable not required (Option Amust also be 00)
3.1in (78.74 mm) = 0031
01 One 3/4-14 NPT fitting, two plugs.
02 3/4-14 NPT (Required if orderingStandoff Adapter Option)
991 Thrust Transmitter
25 25-0-25 mils
70 7.0 meters (23.0 feet)
03 DIN clips and screws
05CSA Division 2, ATEX Zone 0
ATEXZone 2 and includes
ABSmaritime approval
3300 NSv Proximity Probes
330901 3300 NSv Probe
1/4-28 UNF thread,without armor
Minimum unthreaded length: 0.0 in
Minimum case length: 0.9 in
70 7.0 meters (23.0 feet)
02 Miniature coaxial ClickLoc connector
standard cable
05 Multiple Approvals
3300 XL 8 mm Proximity Probe
330103 3300 XL 8 mm Probe
M10 x 1 thread,without armor
Minimum unthreaded length: 0 mm
Minimum case length: 50 mm
10 1.0 meter (3.3 feet)
02 Miniature coaxial ClickLocconnector
standard cable
00 Not required
3300 XL Proximitor Sensor
3300 XL Proximitor Sensor
12 1.0 meter (3.3 feet) system length
nomounting hardware
05 CSA, ATEX, IECEx Approvals
3300 XL 8 mm Reverse Mount Probes
3300 XL 8 mm Reverse Mount Probes
330106-05-30-CC-DD-EE M10 x 1 threads
05 0.5 meter (1.6 feet)
12 Miniature ClickLoc coaxialconnector
FluidLoc cable
05 CSA, ATEX, IECEx Approvals
3300 XL 8 mm Proximity Probes
330101 3300 XL 8 mm Probe
3/8-24 UNFthread, without armor
Minimum unthreaded length: 0.0 in
Minimum case length: 2.3 in
05 0.5 meter (1.6 feet)
02 Miniature coaxial ClickLocconnector
standard cable
00 Not required
PROGRAMMABLE CONTROLLER MODULE
PROGRAMMABLE CONTROLLER MODULE
CONTROLLOGIX 5580
3 MB USER MEMORY
2 GB SD CARD MEMORY
100 ETHERNET/IP NODE CAPACITY
1 USB PORT
1 ETHERNET/IP PORT
1200 MA AT 5.1 VDC/5 MA AT 1.2 VDC
0 TO 60 DEGREE C OPERATING TEMPERATURE
SAFETY CONTROLLER
SAFETY CONTROLLER
20MB STANDARD MEMORY
6MB SAFETY MEMORY
USB PORT
1 GB EMBEDDED ETHERNET PORT
250 ETHERNET/IPDEVICES
4 CHARACTER ALPHA/NUMERIC DISPLAY
SAFETY CONTROLLER
SAFETY CONTROLLER
GUARDLOGIX5580
WITH 3MB STANDARD MEMORY & 1.5 MB SAFETY MEMORY
USB PORT
1 GB EMBEDDED ETHERNET PORT
100 ETHERNET/IP DEVICES
4 CHARACTER ALPHA/NUMERIC DISPLAY
POWER METER
Operating Voltage:85–265V AC/DC
Nominal: 120/208V
Maximum: 690V AC
Burden: <0.2VA per phase
Standard CTs: 1A or 5A
Burden: <0.1VA at 5A
Voltage/Current: ±0.2% of reading
Power/Energy: ±0.5%
Frequency: ±0.01Hz
Panel Controller
RPC420 Panel Controller for each manual lever
RAM: 512MB (minimum)
Flash Storage: 4GB
2x Ethernet (10/100/1000 Mbps)
4x RS-232/RS-485 (configurable)
1x CAN bus
1x USB 2.0
Input Voltage: 24VDC
Power Consumption: 50W (typical)
Copyright Notice © 2004-2024 amikong.com All rights reserved
Disclaimer: We are not an authorized distributor or distributor of the product manufacturer of this website, The product may have older date codes or be an older series than that available direct from the factory or authorized dealers. Because our company is not an authorized distributor of this product, the Original Manufacturer’s warranty does not apply.While many DCS PLC products will have firmware already installed, Our company makes no representation as to whether a DSC PLC product will or will not have firmware and, if it does have firmware, whether the firmware is the revision level that you need for your application. Our company also makes no representations as to your ability or right to download or otherwise obtain firmware for the product from our company, its distributors, or any other source. Our company also makes no representations as to your right to install any such firmware on the product. Our company will not obtain or supply firmware on your behalf. It is your obligation to comply with the terms of any End-User License Agreement or similar document related to obtaining or installing firmware.