SISNet Terminator Assembly
1-wide SISNet Terminator Assembly
(right-hand extender card and two termination resistors)
KJ4001X1-NA1 Horizontal LocalBus Dual Right Cable Extender
KJ4001X1-NB1 Horizontal LocalBus Dual Left Cable Extender
XY/GAP Dual Vibration Monitor
0 1 0-3 mils peak-to-peak (pp)
0 1 3300 8 mm, 3300 XL 8mm or7200 5 mm and 8 mm
Proximitor Sensor, 200 mV/mil
0 2 Hermetically-sealed
0 1 CSA/NRTL/C
0 0 None
0 2 3X
Terminal Block Interface Module
Rated Voltage: 300V AC/DC
Rated Current: 8A per terminal
Contact Resistance: ≤ 5mΩ
Dielectric Strength: 2500V AC (50/60Hz, 1 min)
Insulation Resistance: ≥ 100MΩ (at 500V DC)
3300 XL 11 mm Proximity Probes
330704 3300 XL 11 mm Probe
M14 x 1.5 thread,with armor
Minimum unthreaded length:10 mm
Minimum length:60 mm
10 1.0 meter (3.3 feet)
11Miniature coaxial ClickLocconnector
with connectorprotector, FluidLoc cable
00 Not required
3300 XL 11 mm Extension Cable
3300 XL 11 mm Extension Cable
080 8.0 meters (26.2 feet)
13 Armored FluidLoc cable
withconnector protector
00 Not required
3300 NSv Extension Cable
3300 NSv Extension Cable
045 4.5 meters (14.8 feet)
03 Without stainless steel armor
with connector protector
00 Not Required
3300 NSv Proximity Probes
330903 3300 NSv Probe
M8X1 thread,without armor
Minimum unthreaded length:0 mm
Minimum length: 50 mm
05 0.5 meter (20 in)
01Miniature coaxial ClickLoc connector
with connector protector, standardcable
00 Not required
3300 XL 8 mm Proximity Probes
330101 3300 XL 8 mm Probe
3/8-24 UNFthread, without armor
Minimum unthreaded length: 0.0 in
Minimum case length: 4.3 in
15 1.5 meter (4.9 feet)
02 Miniature coaxial ClickLocconnector
standard cable
05 CSA, ATEX, IECEx Approvals
Velomitor CT Velocity Transducer
02 Stud 3/8-in 24 to 1/2-in 20
00 MIL-C-5015 connection interface
Sensitivity:3.94 mV/mm/s (100 mV/in/s)±5%.
Transverse Response:Less than 5% of the axialsensitivity
Amplitude Linearity:±2% to 63.5 mm/s pk(2.5 in/s pk)
Output BiasVoltage:10.1 Vdc ± 1.0 Vdc, Pin
Proximity ProbeHousing Assemblies
16 3300 XL 8mm probe
10 1.0 m (39 in)
3.5 in (88.9 mm) = 35
9.8 in (248.92 mm) = 098
03One 3/4-14 NPT plugOne 3/4-14 to 1/2-14 NPT reducer
One cable seal grip with grommets forthe following cable sizes:
1/8 to 3/16 inches
1/4 to 5/16 inches
5/16 to 3/8 inches
023/4-14 NPT
Display Interface Module
System Event List
Alarm Event Lists
All Channel, Monitor, Relay Module
Keyphasor* Module or TachometerModule data
135799-02:3500/93 Display Interface Module
(use with A05 thru A08 options)
S-Series DO 32-Channel 24 VDCHigh-Side Card
Local Bus Power :12 VDC at 150 mA
Bussed Field Power:24 VDC at 3.2 A/Card
Field Circuit:24 VDC at 100 mA/Channel
Ambient Temperature:-40°C to +70°C
Shock:10g ½ Sinewave for 11msec
Vibration:1mm Peak to Peak from 2 to 13.2Hz;
0.7g from 13.2 to 150Hz
1-Wide I/O Carrier ExtenderRight
VS6051
CABLE EXTENDER
DUAL RIGHT EXTENDER
8 AMP
12.6 VDC
LOCALBUS
Horizontal LocalBus Dual Right Cable Extender
VIBRATION MODULE
Velocity: 0–20 mm/s
Displacement: 0–500 µm
Frequency Range:10 Hz – 10 kHz
A/D Resolution:16-bit
Sampling Rate:Up to 50 kHz
Power Supply:24V DC
Power Consumption:5W typical
I/O Protection Module
Accessory Boards:8 Boards
Ambient Temperature Rating:-30 to 65 Degrees Celsius
Base Circuitry Coating:Special Protection
Assembly Type:IS220 Standard Modular
Chassis Style:Rough Vented
Port Styles:2 Ethernet (Pictured)
Operating temperature: -30 to 65oC
Power Supply Voltage: 24 V dc
MicroLogix Controlle
PLC MODULE
MICROLOGIX-1000
20 INPUT / 12 OUTPUT
120/240 VAC
32 I/O
(20) 120V AC DIGITAL INPUT
(12) RELAY OUTPUT
ANALOG INPUT MODULE
ANALOG INPUT MODULE
32 CHANNEL
P72122-4-0788722
Current: 4–20 mA, 0–20 mA
Voltage: 0–10 V, ±10 V, 1–5 V
Resolution: 16-bit
Accuracy: ±0.1% of full scale
Power motherboard
Manufacturer: Siemens AG
Part Number: A5E00730540
Input Voltage: 24V DC
Output Voltage: +5V, ±12V
Operating Temperature: 0°C to +60°C
Storage Temperature: -40°C to +85°C
Rack Power Supply Module
Number of channels: 6
Input span: 4-20 mA
Termination resistors: 121 Ohm
Technology: Surface Mount
Common Mode Voltage Range: ±5 V
Maximum Lead Resistance: 15Ω
Analog output current: 0-20 mA
Operating temperature: -30 to 65 °C
Compact CPU
SIMATIC S7-300
CPU 313C-2DP COMPACT CPU WITH MPI
16DI/16 DO, 3 FAST COUNTERS (30 KHZ)
INTEGRATED DPINTERFACE
INTEGRATED 24V DC POWER SUPPLY
32 KBYTEWORKING MEMORY
MICRO MEMORY CARD REQUIRED
Charging Control Board
Input Voltage Range: 380-480V AC (3-phase)
Output Voltage: 12-600V DC
Charging Current: 10-100A
Efficiency: >92%
Frequency: 50/60Hz ±5%
Voltage Accuracy: ±0.5% of full scale
Current Accuracy: ±1% of full scale
Interconnect Cable
Rack End: 16-pin male connector
Field End: Typically M12 connectors
Number: 16 individual shielded twisted pairs
Gauge: 22 AWG stranded copper
3300 XL Proximitor Sensor
3300 XL Proximitor Sensor
10 1.0 meter (3.3 feet) system length
panel mount
05 CSA, ATEX, IECEx Approvals
3300 XL 8 mm Proximity Probes
330102 3300 XL 8 mm Probe
3/8-24 UNFthread, with armor
Minimum case length: 9.6 in
05 0.5 meter (1.6 feet)
02 Miniature coaxial ClickLocconnector
standard cable
05 CSA, ATEX, IECEx Approvals
Copyright Notice © 2004-2024 amikong.com All rights reserved
Disclaimer: We are not an authorized distributor or distributor of the product manufacturer of this website, The product may have older date codes or be an older series than that available direct from the factory or authorized dealers. Because our company is not an authorized distributor of this product, the Original Manufacturer’s warranty does not apply.While many DCS PLC products will have firmware already installed, Our company makes no representation as to whether a DSC PLC product will or will not have firmware and, if it does have firmware, whether the firmware is the revision level that you need for your application. Our company also makes no representations as to your ability or right to download or otherwise obtain firmware for the product from our company, its distributors, or any other source. Our company also makes no representations as to your right to install any such firmware on the product. Our company will not obtain or supply firmware on your behalf. It is your obligation to comply with the terms of any End-User License Agreement or similar document related to obtaining or installing firmware.