Trigger Voltage/Current:+15 V/-10 V
Switching Frequency: Up to 20 kHz
Isolation Voltage: ≥2000 V AC
Logic Supply: +24 V DC (±10%)
Gate Driver Supply: ±15 V DC
Operating Temperature: 0–55°C
Power Supply (Control Section): 24 V DC (±20%)
DC Link Voltage Handling:500–800 V DC
Motor Compatibility: up to 100s of kW
Switching Frequency: 2–16 kHz
Digital Inputs/Outputs:≥6 DI/DO
Analog Inputs:≥2 × ±10 V, 4–20 mA
Operating Temperature: 0–45°C
Voltage Range: 3-phase AC input
Frequency: 50/60 Hz (±5%)
DC Link voltage:510–720 V DC
Continuous Current (DC Link): Up to 60–80 A
Auxiliary Voltage Supply: 24 V DC
Aambient Temperature: 0–40°C
Supply Voltage: 24 V DC (±20%)
Power Consumption: ≤15 W
Motor Compatibility: up to 55 kW
Standard Communication:PROFIBUS DP
Operating Temperature: -20°C to +60°C.
Relative Humidity: ≤95% (non-condensing)
Voltage Range:380–480 V AC
Frequency: 50/60 Hz ±5%
Rated Current:20–200 A
Continuous Power: 10–150 kW
Operating Temperature: -10°C to +50°C (storage up to +70°C)
DIGITAL INPUT MODULE
32 CHANNEL
24 VDC
ISOLATED
50 MA
PULSE WIDTH OUTPUT FUNCTION
TIME-PROPORTIONAL OUTPUT FUNCTION
STATUS DISPLAY
NO EXPLOSION PROTECTION
Number of input channels:64
Rated input voltage:24 V DC
Input ON voltage:20 to 26.4 V DC
Input OFF voltage :5.0 V DC or less
Input current :2.5 mA±20 % / channel
Maximum allowable input voltage:30.0 V DC
Input response time :8 ms or less
Minimum ON detection time:20 ms
Maximum ON/OFF cycle:25 Hz
Maximum current consumption:500 mA (5 V DC)
EC402 ESB Bus Coupler Module
5 Standard type with no explosion protection
E Standard type with explosion protection
0 Basic type
1 With ISA Standard G3 option
Operating Voltage:24 V DC
Number of inputchannels:8, isolated channels
Input frequency :0 to 10 kHz
Minimum input pulse width:40 µs
Pull-up resistance:68 kΩ (12 V DC or 24 V DC)
Filter:Filter for eliminating chattering can be set
Data update period:2 ms
PROFIBUS/MPI or PROFINET
Control Voltage: 24 V DC (±15%)
Output Switching Frequency: 1–16 kHz
Isolation Voltage: ≥2.5 kV AC
Operational Temperature: 0°C to +50°C
Inverter control board
IGD9 for devices 510-620 V DC
1300 A
Logic Supply Voltage: +24 V DC (±10%)
DIP Switches:0–10 V, 4–20 mA
Operating Temperature: 0°C to +40°C
Humidity: ≤95% (non-condensing)
Control Voltage: 24 V DC (±10%)
Isolation Voltage: ≤2.5 kV AC
Output Frequency: ≤20 kHz
Max Output Current: 3–5 A
Signal Logic: 0–24 V DC control signals
Operating Temperature: –10°C to +55°C
Storage Temperature: –40°C to +85°C
Relative Humidity: ≤93% (non-condensing)
Logic Circuit: 24 V DC
Isolation Voltage: ≥2.5 kV AC
Output Current: Up to 2–3 A
Frequency Range: 1 kHz–20 kHz
Operating Temperature: 0°C to +60°C
Humidity: ≤95% (non-condensing)
SIMOTRAS HD Snubber circuit
Rated Voltage (Unm): 690 V AC (50/60 Hz)
Operating Voltage Range: 200–750 V AC
Capacitance: 10–50 μF
Impedance Range: 5–50 Ω at 50 Hz
Dielectric Strength: 2.5 kV AC
INVERTER MOTHERBOARD
FOR ACS580
3AXD50000716975
Input Voltage Range:380–500V AC (3-phase)
DC Bus Link:Integrated protection
Control Voltage:24V DC
Logic Board Power:Switch-mode PSU
Communication Isolation:1500V AC reinforced
Operating Temp:-15°C to +45°C
Input Voltage:380–690V AC
Output Power:up to 630 kW
Control Voltage:24V DC (±10%)
Ambient Operation:-15°C to +50°C
Humidity Protection:<95% non-condensing
CE Mark: Low Voltage Directive
Digital I/O: 6 programmable DI
Analog I/O: 2x 0–10V/4–20mA
Input Power (AC):400–690V (±10%) 3-phase
Motor Power Range:250kW–1.5MW
Control Voltage:Single-phase 26V DC to 30V DC (±15%)
Operating Temp:-15°C to +50°C
Harsh Environment:UL 1203
Busbar Terminals:values 8.9Nm ±0.5
AS-Interface Safety ATEX Gateway
Input Voltage:200–690V AC (-15%/+10%)
Power Range:15–400kW
Control Voltage:Single-phase 24V DC
Relay Outputs:4 × Form-A
AF-650PG: Profibus DP or CANopen
Low Voltage (LV): 380–480V AC
Optional High Voltage (HV):500–690V AC
Short-Circuit Current Rating (I_SC): ≤100 kA
Inrush Current Limit: ≤150% × rated input current
Isolation: ≥2.5 kV
Dynamic braking fuses:690V AC, 100–800A
Ambient Temp Range: -15°C to +45°C
Storage Humidity: ≤95% non-condensing
Points:32, commoned
Nominal input voltage:24 V DC
Operational voltage range:15–30 V DC
Absolute maximum input voltage:33 V DC
Absolute maximum reverse input voltage:–0.6 V DC
Input delay:<10 ms, On to Off or Off to On
ADC scan time:<1 ms for all 32 points
Points:16, commoned
Nominal output voltage:24 V DC
Operational voltage range:15–30 V DC
Absolute maximum output voltage:33 V DC
Absolute maximum reverse input voltage:–0.6 V DC
Leakage to load (Off-state):<1 mA
On-state voltage drop:<1 V DC @ 1.5 A
Loop-back scan time:<1 ms for all 16 points
Points:32, commoned
Nominal input current:4–20 mA DC
Operational current range:2–22 mA DC
Absolute maximum field voltage:33 V DC
Absolute maximum input current:50 mA DC
Input bandwidth (3dB):16 Hz
Source impedance:180 Ω
Resolution:12 bits
Absolute error:0.15% of full scale (20 mA)
Diagnostic:Force-to-value diagnostic (FVD)
Scan time:<1 ms for all 32 points
Offers a distance-to-spot ratio of 50:1
Works with most K-type thermocouples
Allows easy access to advanced features
with soft-key buttons and graphical display
Captures up to 99 points of data for
quick downloading to a PC through the USB connection
Quickly identifies problems with MIN, MAX, AVG, and DIF functions
Easily adapts to lighting conditions with a two-level backlight
R8 SINGLE MODULE SP KIT
Forward Voltage: 1200–2500V range
Average On-State Current:500–2000A
Surge Current :10–50 kA
Isolation: ≥2000 V AC
Junction Temperature:>125°C
Supply Voltage:24V DC
Analog Inputs: 0–10 V / 4–20 mA
Communication Ports: Terminals for RS-485
Isolation Rating: ≥1500 V AC
Power Handling: 5-10A
Operating Temperature: -25°C to +70°C
DC Link Voltage Range: 380–525V/690V DC
Current Capacity:50–500 kW
Switching Components:high-power IGBT module
Gate Driver Outputs: 2–16 kHz
Isolation: 2.5 kV
Protocol Support:24V DC signals
Temperature: -10°C to +80°C
Humidity: <95% RH non-condensing
DC Link:1200V
Continuous: 1400A
Pulsed Current: 2000–2800A
Frequency: ≤5 kHz typical
Max. withstand voltage of 1800V
Typical Motor Load: 500–2000 HP induction motors
Voltage Class:1200V
Continuous Current : 650A
Maximum Current: Up to 1300A
Collector-Emitter Saturation Voltage : 2.0–3.0V
Isolation: ≥2500 V DC
Thermal Resistance <0.1°C/W
Voltage: +15V/-8V gate control
Operating Temperature: -40°C to +125°C
DBV / dBm measurement
1 μV resolution in DC mV range
Current measurement 20 A
(30 seconds momentary, 10 A continuous)
Peak capture function to record transients as fast as 250 μs
Continuity / Conductance / Capacitance
Resistance and continuity
Duty cycle & pulse width measurement
Min / Max / Average with Time Stamp to record signal fluctuations
Real time and elapsed time modes
CAT III 1000 V / CAT IV 600 V safety rated
Number of inputchannels:8, isolated channels
Input frequency :0 to 10 kHz
Minimum input pulse width:40 µs
Pull-up resistance:68 kΩ (12 V DC or 24 V DC)
Filter:Filter for eliminating chattering can be set
Data update period:2 ms
EC401 ESB Bus Coupler Module
5 Standard type with no explosion protection
E Standard type with explosion protection
0 Basic type
1 With ISA Standard G3 option
Function: ESB bus interface function
Number of connectable units: Max. 9 units (*1)
Transmission speed: 128 Mbps
Transmission distance: Max. 10 m
Current consumption: 0.5 A
EC402 ESB Bus Coupler Module
5 Standard type with no explosion protection
E Standard type with explosion protection
0 Basic type
1 With ISA Standard G3 option
Actuator Compatibility:spring-return actuators
Supply Pressure Range: 3–30 psi
Input Signal: 4–20 mA
Port Sizes: 1/4" NPT or G1/4 threaded ports
Temperature Range: -40°C to +85°C (-40°F to +185°F)
Ability to de-energizel
Ability to de-energize via secondary meansl
Cross talk between outputsl
Function of the suppression diodesl
Lead breakage in the (external) output wiringl
Short circuit of the outputs
Sensitivity:3.94 mV/mm/s (100 mV/in/s)±5%.
FrequencyResponse:3.0 Hz to 900 Hz (180 to 54,000cpm) ±1.0 dB
TemperatureSensitivity:-8% to +5% typical over theoperating temperature range
TransverseResponse:Less than 5% of the axialsensitivity.
Output BiasVoltage:10.1 Vdc ± 1.0 Vdc, Pin Areferenced to Pin B
Points:32, commoned
Nominal input current:4–20 mA DC
Operational current range:2–22 mA DC
Absolute maximum field voltage:33 V DC
Absolute maximum reverse field voltage:– 0.6 V DC
Absolute maximum input current:50 mA DC
Input bandwidth (3dB):16 Hz
Source impedance:180 Ω
Resolution:12 bits
Absolute error:0.15% of full scale (20 mA)
Diagnostic:Force-to-value diagnostic (FVD)
Points:32, commoned
Nominal input voltage:24 V DC
Operational voltage range:15–30 V DC
Absolute maximum input voltage:33 V DC
Absolute maximum reverse input voltage:–0.6 V DC
Input delay:<10 ms, On to Off or Off to On
ADC scan time:<1 ms for all 32 points
Points:16, commoned
Nominal output voltage:24 VDC
Specified operational voltage range:15 to 30 VDC
Absolute maximum output voltage:33 VDC
Absolute maximum reverse input voltage:– 0.6 VDC
Leakage to load (Off state):<1 mA
Diagnostic glitch duration <2 ms, maximum:500 Ps, typical
On state voltage drop:<1.0 VDC @ 1.5 A
I/O Channels: 4–20 mA
Scalability: 8–16 I/O points per module
Data Transfer Speed: Up to 100 Mbps
Voltage: 18–32 VDC
Current Draw: <2 A typical
Operating Temperature: –40°C to +70°C
Storage Temperature: –50°C to +85°C
Humidity: 5–95% RH (non-condensing)
Slots: 1–2 x SODIMM slots
Capacity: Up to 16–32 GB
Chipset: Intel H110/Q170 or AMD
Network:2–4 x Gigabit Ethernet
Power Input:12–24 V DC
Wide operating temperature:(-40°C to +85°C with proper airflow)
Humidity tolerance: 5–95% (non-condensing)
RX3I NIU WITH TWO SERIAL PORTS
20K OF LOCAL LOGIC
MODULE REQUIRES UNIVERSAL BASE (IC695CHSXXX)
REQUIRES ETHERNET MODULE (IC695ETM001)
NIU SUPPORTS ALL RX3I I/O MODULES
Communication Protocol:Modbus TCP/IP, DeviceNet
Data Rate:Up to 1 Mbps
Power Consumption:L ess than 4W
Operating Temperature:-40C to +70°C
Mounting Type:Panel Mount
INTERFACE BOARD
SMC FLEX INTERFACE PCB BOARD
FOR SOFTSTART
Input Voltage:24V DC
Communication Ports:RS-485, EtherNet/IP
Current/Power Ratings:5A at 240V AC
Analog I/O: Standard 0-10V
ACS880-04 drives
3AXD10000497831
LV AC industrial single drive module
IEC: Pn 500 kW, 715 A, 500 V
UL: Pld 600 Hp, 705 A, 460 V
Number of Phases:3-phase
Enclosure Type NEMA:Open Type
Operating Humidity (RHamb):5 ... 95
Sound dB (A):72 dB(A
Frequency (f): 47.5 ... 63 Hz
Frame Size: R11
Input Voltage (Uin):380 ... 500 V
MotiFlex e180
MFE180-04AN-05A0-4+L518+N8020
3P, 380 VAC
IN: 5 A, HALL incremental encode
A free Mint programming license
easy positioning tasks
drive supports various feedback types
LV AC machinery drive module
IEC: Pn 3 kW, 8 A, 400 V
UL: Pld 5 Hp, 7.6 A, 480 V
(ACS880-M04-08A0-5)
Number of Phases:3-phase
Degree of Protection:IP20
Enclosure Type NEMA:Open Type
Altitude:1000 m
Operating Humidity (RHamb):5 ... 9
Power Factor:0.98
Sound dB (A):47 dB(A)
Output Power: 1.1 kW
Output Voltage: 380–480 V AC, 3-phase ±10%
Continuous current: 4.5 A (at 40°C)
Dynamic peak current: Up to 7.0 A
Input Voltage: 3-phase 380–480 V AC
Input Current (Typ.): 4.6 A @ 480 V AC
Supply Voltage: 24 V DC
Power Consumption: ≤ 5 W
Isolation Voltage: 500 V AC
Voltage range: 0–30 V DC
Logic thresholds: ≤ 5 V DC
Ethernet/IP: TCP/IP, IPv4,
Normalizing module
ABO for devices 660-690 V
3 AC and 890-930 V DC
82 A
Input Voltage (DC Link): 890–930 V DC
Rated Braking Current: 82 A continuous
Compatible AC Line Voltage Range: 660–690 V
Mains Connection Terminals: 3-phase AC supply
Siemens MM440 Inverter
Voltage Range: 3-phase 380–480V AC (±10%)
Current Rating:up to 200A
Power Output: 0.37 kW to 250 kW
Switching Frequency: 2–16 kHz
Communication Interfaces: 0–10V, 4–20mA
allocation board
with functional safety A5E42928536
Supply Voltage: 24V DC (±15%)
Power Consumption: ≤5W
Operating Current per Channel: 100 mA
Isolation Voltage: 500V AC
Operating Temperature: -20°C to +60°C
Relative Humidity: ≤95%