Perfect Harmony Medium voltage drive
PERFECT HARMONY power cell G4 Cell 200A, 750 V.
Current: 200 A
Voltage (DC Link): 750 V DC
Power: 150 kW
Frequency: Up to 3 kHz
Dead-Time Compensation: <1 μs IGBT offset
Auxiliary Power Input:24 V DC
Robicon G4 Power CELL, 140A, 750V
Perfect Harmony Medium voltage drive
LDZ10500424.140
Voltage (DC Link): 750 V DC ±10%
Rated Current (Continuous): 140 A
Power Rating: 105 kW
Operating Temp.: Max cell temperature ≤85°C
Capacitors: 12,000 µF ±20% 900 V DC
CPU BOARD ELECTRONIC MODULE
FOR CONVERTER
RAM ≤ 256 MB
Flash ≤ 512 MB
Digital I/O:24 VDC, ±10%
Analog Inputs: 0–10 V/4–20 mA
Input Voltage: 24 VDC ±10%
Isolation: Reinforced (3000 VAC)
Max Power Draw: 20–50 W
GEN5 VFD Power Cell
GH180 Medium Voltage Drives
Voltage Class:3.3 kV
DC Link Voltage: Standard 750 V DC
L-L Nominal:3.3 kV–6.9 kV
Continuous Output Current: 240–300 A
Processor Type: 32-bit or 64-bit RISC-based
Program Memory: 512 KB–8 MB
Data Memory: 64 KB–2 MB
Execution Speed: ~0.1–0.3 μs
Analog I/O:4–20 mA or ±10 V inputs
Voltage Rating: 24 VDC (±15%)
Power Consumption: 10–30 W
Operating Temperature: 0°C to 55°C (32°F to 131°F)
Storage Temperature: -25°C to 75°C (-13°F to 167°F)
3300 XL 11 mm Probe
M14 x 1.5 thread,without armor
10 1.0 meter (3.3 feet)
01Miniature coaxial ClickLocconnector
with connectorprotector, standard cable
05 Multiple Approvals
Model: 16925 - Interconnect Cables
Cable Length Option in feet: -35 - 33 ft
Capacitance: 50–60 pF/m
Impedance: 50 Ω
Voltage Rating: Operates within -24V DC
Signal Type: Supports low-voltage AC/DC
Temperature Range: -40°C to +150°C
Sensor Proximity Probe Cable
Capacitance: 50–60 pF/m
Characteristic Impedance: 50 Ω or 93 Ω
Voltage Rating: Rated for -24 V DC
Temperature Range: -40°C to +150°C
Humidity: Resistant up to 95% non-condensing
Voltage Class: Medium Voltage
Series: Perfect Harmony GH/VFD 180
Power Range: Up to 50–100 MW
Input Voltage 50/60 Hz, 3-phase
Output Voltage:0–60 Hz variable
Output Current (max):150–3500 A
SINAMICS PERFECT HARMONY GH180 Drives CCB
Communication Interfaces:Fiber-optic loops
Input/Output:24-bit I/O
Power Supply:24 V DC (±20%)
Ambient Temp.:0°C – +50°C
DC link/integrated power module
Input rectifiers
Output IGBTs in drives
Voltage Rating:690–1000 VDC
Current Rating (Cont.):450–700 A
Interrupting Capacity:≥100–150 kA
Series: Innomotics G5 Drive
Function: Power Submodule for MV Drive Systems
Current Rating (Cont.):45 A
Voltage Rating:750 V DC
Overload Capacity:Up to 150% current for 60 s
Switching Frequency:Optimized ≤20 kHz
Topology:IGBT Half-Bridge Module
Input Voltage:3-phase AC 6.6 kV
Output Frequency Range:0.0–120 Hz
Rated Power:5–40 MW
Output Voltage (Motor):3 kV to 6.6 kV
Overload Capacity:120% of rated current
Efficiency:>97%
Operating Temperature:0°C to +40°C
Ambient Humidity:Up to 95% non-condensing
Series: NXGPRO Plus NCP
Input Voltage:90 – 290 V AC ³ph
Output Voltage (DC):±24 V/48 V DC
Rated Current Per:Cell ≥200 A
Power Rating:6 kW per cell
Efficiency:≥95%
Resilient Networks: -48 V/24 V
GH180 NXGpro USER I/O board
Voltage Input:24 V DC (±10%)
Mounting: Secured within GM150 Cabinet
Operating Temperature: 0°C – 55°C
RUN/STOP: Operational mode of the board
Voltage: 380–690V AC (±10%), 3-phase
Frequency: 50/60 Hz.
Nominal: 930V DC
Control Circuit Voltage: 24V DC (±15%)
Analog inputs :0–10V, 4–20mA
Temperature: -10°C to +50°C (derate 2% per °C above 40°C)
Humidity: <95% non-condensing
Series: SINAMICS Perfect Harmony GH180
Type: Medium Voltage (MV) Power Cell
Phase Voltage:230/690 VAC input
Cell Output DC Link Voltage:750–950 VDC
Rated Current (Continuous):200–300 A
Switching Frequency:≤250 Hz
Efficiency:≥97%
SIMATIC ET 200SP
PROFIBUS bundle IM
IM 155-6DP HF, max
32 I/O modules and 16 ET 200AL modules
Multi-hotswap
bundle consists of: Interface module (6ES7155-6BU01-0CN0)
Server module (6ES7193-6PA00-0AA0)
PROFIBUS connector (6ES7972-0BB70-0XA0)
Series: Gen3 Power Cell Family
Manufacturer: Siemens AG
Input Voltage (DC): 500–900 VDC
Output Voltage (AC): 400 VAC
Rated Power: Up to 315 kW
Efficiency: ≥97%
Phase Configuration: 3-phase output
Frequency: 50/60 Hz
Series: GE Mark VIe Series
Input Voltage: 24 V DC (±10%)
Power Consumption: ≤8 W
Voltage Range:0–30 V DC or 0–120 V AC
Range: 0–10 V DC, 4–20 mA
Resolution: 16-bit ADC
Type: Form-C contact relays (1 A at 30 V DC)
Operating Temperature: -40°C to +70°C
Relative Humidity: 5–95% (non-condensing)
Series: GE Mark VIe Series
Input: 24 V DC (±10%)
Isolation: ≥1.5 kV
Digital Inputs:0–30 V DC
Analog Resolution:16-bit ADC
Operating Temperature: -40°C to +70°C
Shock/Vibration: to 5 G (5–500 Hz)
Series: GE Mark VIe Series
Terminal Capacity: ≤32 AWG
Input Voltage: 24 V DC (±10%)
Power Consumption: <5 W
Galvanic Isolation: Up to 1.5 kV AC/DC
Voltage Range for Inputs: 0–120 V AC/DC
Digital Inputs (DI):30 V DC/120 V AC
Operating: -40°C to +70°C
Storage: -40°C to +85°C
Humidity Tolerance: 5–95% non-condensing
Series: GE Mark VIe
Dual Power Inputs: Isolated 24 V DC
Fail-safe relay contact rating: 2 A at 24 V DC
Input Voltage: 24 V DC (±10%)
Temperature Range: -40°C to +70°C (continuous operation)
Surge Protection: TVS diodes/SRC filters on I/O channels
Relative Humidity: 5–95% (non-condensing)
Operating Voltage:24 V DC ±10%
Power Consumption: <10 W
Types: 2-wire, 3-wire
Number of Inputs: 8 channels
Excitation Current:1 mA
Measurement Resolution: ≤0.1°C
Series: Mark VIe
Product Type: Relay Output Terminal Board
Number of channels: 16
Relay Type: SPDT
Relay Contact Rating: 10A
Input Voltage Range: 12V, 24V
Number of Relay Channels: 4, 8
Relay Switching Current: Max 10A
Mounting Type: DIN rail
Output Resolution: 12-bit
Output Impedance: 10 Ohm
Analog outputs: 0-20 mA
Series: GE Mark VIe
Input Voltage: 24 V DC (±10%)
Power Consumption: ≤15 W
Proximity Probes: 0–10 kHz
Accelerometers: Up to 20 kHz
IEPE sensor excitation:typically 18–24 V DC
Analog input: ±10 V peak
Operating Temperature: -40°C to +70°C.
Humidity Tolerance: 5–95% (non-condensing)
Input Voltage: 24 V DC (±10%)
Power Consumption: Typically <20 W
Sampling Rate:Up to 25.6 kS/s
Voltage ranges (analog): Typically ±10 V DC
Analog Input: 16-bit
Operating Temperature: -40°C to +70°C
Storage Temperature: -40°C to +85°C.
Relative Humidity: 5%–95% (non-condensing)
Power supply:115 / 230 V AC
Load AC: Pmax: 12 VA
Load DC: Pmax: 7 W
Standard delivery:230 V AC
Sensitivity:10 mV/g
Power requirement :-24 V DC / 5 mA
Current requirement:+ 4 mA / Ri < 4 kΩ
Input:1 Vpp; 10 Hz < fo < 1 kHz
SINAMICS S120 Drive System
Voltage Support:510–720 V DC
Maximum Resolution: 16-bit digital I/O handling
Operating Temperature: 0°C to +55°C
Compatible SINAMICS S120 Modules
Output Range: 4–20 mA
Current Regulation Accuracy: ±0.1% of full scale @ 20°C
Maximum Loop Resistance: ≤500 Ω
Minimum Load: Device must sustain ≥3.5 mA
Power Supply:24 VDC ±10%
Isolation: 500 VAC galvanic isolation
Operating Temperature: –20°C to +60°C
Relative Humidity: 5–95% (non-condensing)
Robicon Power Cell
Input Voltage:750–900 VDC
Rated Power: Up to 250 kVA
Continuous RMS: 260–300 A
AC Line-to-Line: 460 V ±10%
Switching Frequency: Up to 500 Hz
Operating: 0°C–55°C
Storage/Derating: Up to 70°C
PRESSURE SWITCH
0-50BAR FOR AIR-COOLED
SINAMICS FOR AIR-COOLED
SINAMICS GM150(IGBT)
Adjustable Threshold Range: 0–50 bar
Switch Type: SPDT
Max Voltage: 250 VAC/24 VDC
Current Rating: 6 A resistive load
Operating Temperature: –25°C to +60°C
SINAMICS S120
SINGLE MOTOR MODULE
INPUT: DC 600V
OUTPUT: 3-PH 400V, 3A
FRAME SIZE: BOOKSIZE D-TYPE INTERNAL
AIR COOLING OPTIMIZED PULSE SAMPLE AND
SUPPORT OF THE EXTENDED
SAFETY INTEGRATED FUNCTIONS
INCL. DRIVE-CLIQ CABLE
ASI Robicon
Harmony NXG DCR Box Drive Control
DC-Link Voltage Range: 510–930 VDC
Current Capacity: Up to 1,000 A
Protection Features:±2% tolerances
Operating Temperature: –10°C to +50°C
Voltage: 3-Phase, 400–690 VAC
Frequency : 50/60 Hz (±5%)
Main Output: 24 VDC
Current Range: 10–20 A
Ripple Noise: <1%
Auxiliary Outputs: Possible ±15 VDC or 5 VDC
Input-to-Output Isolation: ≥2.5 kVAC
Efficiency: Typically ≥85% at full load
MICROMASTER 440
without filter 380-480 V
3 AC +10/-10% 47-63 Hz
constant torque 22 kW
overload 150% 60 s, 200%
3 s square-law torque 30 kW
520x 275x 245 (HxWxD)
degree of protection IP20
ambient temperature -10+50 °C
without AOP/BOP
Component Type: Modular Power Cell
Nominal DC Voltage: 1,000–1,700 VDC
Input Current:50–200 A
AC Output Per Cell:690–1140V AC
Switching Frequency: 0–60 Hz
Insulation Testing: Rated for 5–15 kV
Legacy Status: Sinamics SL150
Robicon A5E39206479
DEV CONTROL SIMATIC HMI
Screen Size:8.4-inch
Brightness:300–400 cd/m²
Power Supply:24 VDC
Power Range: +15%/-20%
Operating: 0–55°C
Storage: -30°C to +70°C
Rated Voltage: 24 V DC
Rated Current: 2 A per contact
Contact Resistance: ≤ 50 mΩ
Insulation Resistance: ≥ 100 MΩ
Dielectric Strength: 500 V AC
Operating Temperature: -25°C to +70°C
Storage Temperature: -40°C to +85°C
Humidity Resistance: 5% to 95% (non-condensing)
Line monitored digital input
Non line monitored digital input
Line monitored ESD input (on Channel 32)
Analog input 0-20mA or 4-20mA
Digital output (0.5 Amp) configurable line monitoring
Multiple digital output (1 Amp or 2 Amp)
with or without line monitoring
Analog output 0-20mA or 4-20mA
330101 3300 XL 8 mm Probe,
3/8-24 UNFthread, without armor
05 0.5 meter (1.6 feet)
02 Miniature coaxial ClickLocconnector
standard cable
00 Not required
28 3300 XL 8 mm probe, multiple approvals
05 0.5 m (20 in)
08 Minimum length 80 mm
080 Minimum length 80 mm
03Two plugs, one M20 fitting
One cable seal grip with grommets forarmored probe cable
02 3/4-14 NPT
28 3300 XL 8 mm probe, multiple approvals
05 0.5 m (20 in)
15 Minimum length 150 mm
080 Minimum length 80 mm
03Two plugs, one M20 fitting
One cable seal grip with grommets forarmored probe cable
02 3/4-14 NPT
SIMOTICS S
synchronous servo motor
1FT6 27 Nm, 100K, 2000 rpm naturally cooled
IP65 IM B5 (IM V1, IM V3)
incremental encoder sin/cos
1 VSS 2048 S/R (encoder I-2048)
for power/signal connectors:
Outlet direction axial DE without holding brake
SINAMICS G120 CONTROL UNIT
CU250S-2 DPINTEGRIERT PROFIBUS
SUPPORT OF VECTORCONTROL
EASY POSITIONING EPOS VIAEXTENDED
FUNCTION LICENSE 4 CONFIGURABLEDI/DO
6 DI (3 F-DI), 5 DI, 3 DO (1 F-DO), 2 AI
2 AOSAFETY INTEGRATED STO, SBC
SS1 FURTHERSAFETY FUNCTIONS VIA EXTENDED
SAFETYLICENSE ENCODER: D-CLIQ + HTL/TTL/SSI
RESOLVER/HTL VIA TERMINAL PROTECTION
IP20USB- AND SD/MMC-INTERFACE
Voltage Rating:400 V AC – 600 V AC
Resistor: 10Ω–200Ω
Power Dissipation: ≥250W
Current Handling:5–50 A transient pulses
Operating Temperature: -25°C to +60°C
Humidity Tolerance: ≤90% non-condensing
AC Line Supply: 3-phase 380–480 V AC
DC Output: 520–650 V DC
Rated Current:18–30 A
Output Power: 15–110 kW
Efficiency: ≥97%
Storage temperature: -25°C to +70°C
Humidity: ≤85% non-condensing
contactor AC-1, 140 A, 690 V
40 °C, 3-pole, 480 V AC, 60 Hz
auxiliary contacts: 2 NO + 2 NC
main circuit: ring cable lug connection,
control and auxiliary circuit: screw terminal
size: S3
COMMUNICATION MODULE
CBC
FOR CAN-BUS COMMS
SPARE PART
SIMOVERT MASTERDRIVES
Isolation: up to 500 V
Supply Voltage: Pulls 24 V DC
Process Data (PZD): 4–6 PZD
Temperature: 0°C – +55°C
TDB MODULE PC BOARD
690VAC
FOR CONVERTER MODULE
3-phase AC Voltage: 690 V AC(±10%)
Frequency Tolerance: ±5%
Isolation Voltage: 2000 V AC
Operating Temperature:-25°C to +55°C
control electronics Standard incl.
terminals C98043-A7100-L1
Primary Supply (Logic): 24 V DC ±10%
Current Handling (Logic): ≤5 A
Analog signal inputs:±10 V, 4–20 mA
Operating: 0°C to +40°C (full rating).
Extended: Optional derating up to +60°C
Humidity: ≤85% (non-condensing)
Input Voltage: 24 V DC
Voltage Range: +15 V to -10 V
Current Capacity: 5–10 A
Switching Frequency: Up to 20 kHz
Galvanic Isolation Voltage: ≥2500 V AC
Operating Temperature: -20°C to +55°C
Storage Temperature: -40°C to +85°C
Control Voltage: 24 V DC
Signal Voltage: 5 V/3.3 V
Switching Frequency:12–16 kHz
Current Ratings:55–160 kW
Overload Capacity: Typically 150%
Temperature: –10°C to +40°C
Humidity: ≤90% (non-condensing)