We offer a comprehensive range of Invensys automation solutions, focusing on core systems from its flagship brands:
Foxboro(I/A Series Distributed Control System)
Triconex(Tricon CX and Trident (Emergency Stop System))
Whether you need components for a specific platform (such as the Foxboro I/A Series or Triconex safety system) or need to source replacement/discontinued parts based on device functionality, inquiry us now
We are committed to sourcing the mission-critical Invensys products you need.
We offer a comprehensive range of Invensys automation solutions, focusing on core systems from its flagship brands:
Foxboro(I/A Series Distributed Control System)
Triconex(Tricon CX and Trident (Emergency Stop System))
Whether you need components for a specific platform (such as the Foxboro I/A Series or Triconex safety system) or need to source replacement/discontinued parts based on device functionality, inquiry us now
We are committed to sourcing the mission-critical Invensys products you need.
Communication Protocol:Modbus TCP/IP, DeviceNet
Data Rate:Up to 1 Mbps
Power Consumption:L ess than 4W
Operating Temperature:-40C to +70°C
Mounting Type:Panel Mount
Power consumption: Typically 15-30W
Operates on 24V DC
Operating Temperature: 0°C to +60°C
Storage Temperature: -40°C to +85°C
Humidity: 5% to 95% non-condensing
Points:32, commoned
Nominal input current:4–20 mA DC
Operational current range:2–22 mA DC
Absolute maximum field voltage:33 V DC
Absolute maximum input current:50 mA DC
Input bandwidth (3dB):16 Hz
Source impedance:180 Ω
Resolution:12 bits
Absolute error:0.15% of full scale (20 mA)
Diagnostic:Force-to-value diagnostic (FVD)
Scan time:<1 ms for all 32 points
Rated Voltage: 24V DC or 120V AC
Current Rating:1-10A
Wire Size Compatibility: 12 AWG to 24 AWG
Operating Temperature Range: -10°C to +60°C
Storage Temperature Range: -20°C to +70°C
Input Type: Dry contact or Wet contact inputs
Wet contact inputs: Typically 24V DC
Power Supply: 24V DC ± 20%
Power Consumption: Approximately 3W
Maximum Power Consumption: 3 watts
Operating Temperature Range: -40°C to +70°C
Storage Temperature Range: -40°C to +85°C
Relative Humidity: 5% to 95%, non-condensing
Points:16, commoned
Nominal output voltage:24 V DC
Operational voltage range:15–30 V DC
Absolute maximum output voltage:33 V DC
Absolute maximum reverse input voltage:–0.6 V DC
Leakage to load (Off-state):<1 mA
On-state voltage drop:<1 V DC @ 1.5 A
Loop-back scan time:<1 ms for all 16 points
Extremely high efficiency
Power factor correction
Dual stage current limiting
Overvoltage shut down circuitry
Transformer isolated 24 V dc output
UL®, UL-C and CENELEC Certifications
G3 rating for harsh environments
Power for external field devices
Relay (form C) status alarm output
Analog Input: 1–5V DC, 4–20 mA
Analog Output: 4–20 mA or 0–10V DC
Voltage: 120/240V AC ±10% (50/60 Hz)
Power Consumption: 5W typical
Operating Temperature: -20°C to +60°C (-4°F to +140°F)
Humidity: 0–95% non-condensing