allocation board
with functional safety A5E42928536
Supply Voltage: 24V DC (±15%)
Power Consumption: ≤5W
Operating Current per Channel: 100 mA
Isolation Voltage: 500V AC
Operating Temperature: -20°C to +60°C
Relative Humidity: ≤95%
Layer 2, 11 bit and 29 bit (CAN 2.0A/B)
CANopen® master on the module
DIP switches for address + transfer rate
Memory card for project backup (optional)
USB interface for parameterization and diagnostics
Extensive CAN bus diagnostics possibilities
Can also be used as CANopen® slave
Extended ambient temperature
SINAMICS S120
Double Motor Module
input: 600 V DC
output: 400V 3AC, 18 A/18 A
design: booksize D type
internal air cooling optimized pulse patterns
and support of the extended Safety Integrated
functions incl. DRIVE-CLiQ cable
SINAMICS S120/S150
Logic-side (control): 24 V DC
Power-side (IGBT control):up to 800 V DC peak
Signal Isolation: ≥2500 V AC
Operating: 0°C to +55°C
Storage: -40°C to +85°C
Light and cost-effective plastic housing
suitable for continuous 24/7 operation
178°H/178°V extra-wide viewing angle
High fidelity digital processing
8ms fast response time
Support multiple signal inputs
such as HDMI, VGA and USB
Physical button
infrared remote dual control mode
SINAMICS S120
SINGLE MOTOR MODULE
INPUT: DC 600V
OUTPUT: 3-PH 400V, 9A
FRAME SIZE: BOOKSIZE D-TYPE
INTERNAL AIR COOLING OPTIMIZED PULSE
SAMPLE AND SUPPORT OF THE EXTENDED
SAFETY INTEGRATED FUNCTIONS
INCL. DRIVE-CLIQ CABLE
SINAMICS S120
SINGLE MOTOR MODULE
INPUT: DC 600V
OUTPUT: 3AC 400V,
30A FRAME SIZE: BOOKSIZE C-TYPE
INTERNAL AIR COOLING OPTIMIZED
PULSE SAMPLE AND SUPPORT OF
THE EXTENDED SAFETY INTEGRATED FUNCTIONS
INCL. DRIVE-CLIQ CABLE
Input Power: 24V DC
Sensor Interfaces: Analog I/O (0-10V/4-20mA)
ARM/X86-based chipsets
Temperature Range: -20°C to +60°C
Humidity Tolerance: ≤95% (non-condensing)
SINAMICS S120 Motor Modules
DC Link Voltage: voltages up to 600–900V
Logic Power Supply: 24V DC ±10%
Real-time IGBT driver control
Operating Temp.: -10°C to +50°C
SINAMICS S120
Adapter cable 4-pole
for connection of the connector X41
for replacement of the CIB module
with a Control Interface Module (CIM)
is only required for air-cooled Power Modules
Inverter Control Board
Input Control Signals:0–10 V or 4–20 mA
Power Regulation: 600–1200 V DC link
Current Handling:50–100 A
Switching frequency range: 1–6 kHz
Operating Temperature: 0–60°C
Power Block Drive Board
DC Link Voltage: 510–720 V DC
AC Output Voltage:400 V AC
Continuous Output: Up to 100–280 A (rms)
Cooling Method: Liquid or forced-air cooling
Thermal Resistance: < 0.05 K/W
SINAMICS TERMINAL MODULE
CABINET TM120
WITHOUT DRIVE-CLIQ CABLE ADD ON BOARD
FOR SINAMICS CONVERTERS
PTC and KTY analog inputs
with safe electrical isolation
Micromaster 440
18.5/22/37KW
Voltage: 3 AC 380–480 V ±10% (50/60 Hz)
Frequency Range: 0–650 Hz
Switching Frequency: 4 kHz
Ambient Temperature: -10°C to +50°C
Humidity: Up to 95% (non-condensing)
SINAMICS S120
Single Motor Module
input: 600 V DC
output: 400 V 3 AC,
9 A type of construction: booksize
internal air cooling optimized pulse patterns
and support of the extended Safety
Integrated functions incl. DRIVE-CLiQ cable
MASTERDRIVES ACCESSORY PACK
SIMOVERT
FOR COMMUNICATION MODULE SIMOLINK SLB
5 M PLASTIC FIBER-OPTIC CABLE
2 FOC CONNECTOR
SAND PAPER FOR WORKING INTERFACE
FIELD SUPPLY C98043-A7115-L11
Input Voltage:3AC 400–480V (50/60Hz)
Field Output Current: 10–110A DC continuous
Stability: ±0.5% of setpoint
Operating Temp: 0°C to +55°C
power Interface incl
terminals C98043-A7105-L4
Armature Supply: Up to 575 V AC (±10%)
Field Supply: Optional 110-600 V DC
Armature Current: 150–900 A
IGBT junction temp ≤125°C
field supply 85 A field current
Digital I/O: Enable (24VDC)
Input Supply: 3AC 400V (±15%)
Internal Logic Power: 24V DC (±10%)
Analog Input (Setpoint): ±10V / 4–20mA
Output Voltage Range: Up to 375 V DC
Regulation Accuracy: ±1% of setpoint
CONTROL BOARD
ELECTRONIC C98043-A1600-L1
Main Processor: Digital Signal Processor
Flash Memory: 4–8 MB
Digital Inputs/Outputs: 16–24V DC I/O ports
Analog Inputs: ±10V or 4–20mA
Voltage Input: Typically 24V DC (±15%)
Supply Voltage:24 V DC (±10%)
Grid Input:380 V AC – 575 V AC, 50/60 Hz
Pulse Frequency:50–60 Hz
Fired Thyristors:current/torque control
Operating Temperature:0°C to +55°C
afety First: Discharge DC link capacitors
SIMOVERT MASTERDRIVES
Snubber Function :up to 1.5–2.5kV
Relay Contacts:Rated for ≥ 850A
Voltage Rating:480V AC , 50/60 Hz
Current Handling:Supporting up to 1200A systems
Control Voltage: +24 V DC (±10%)
Current Consumption: ≤1.5 A
Temperature: 0–55°C ambient
Storage Humidity: ≤93% non-condensing.
Digital I/O Sourcing:10–24 V inputs, ±24 V outputs
Voltage: 24 V DC (±10%)
Analog Reference Signals: ±10 V or 4–20 mA
Output Voltage: Adjustable 0–400 V DC
Output Current:10–20 A continuous
Temperature Range: -10°C to +55°C
Humidity: ≤95% non-condensing
SINAMICS DCM DC converter
for 4-quadrant drives Circuit (B6) A (B6) C
Input: 400V 3AC, 13A
controllable: Field rectifier D420/15
MREQ-GEG6V62
Output: 420 V DC, 15 A
Input Voltage Range:380–480 V AC
Output Voltage (DC):50–250 V DC
Continuous Excitation Current: 10–20 A DC
Analog Input: Accepts ±10 V or 4–20 mA
Internal Logic Supply: Isolated 24 V DC
Temperature: 0°C to +60°C operation (-25°C storage)
Humidity: ≤96% non-condensing
Control Circuit: +24 V DC ±15%
Sensor Integration: 0–10 V/4–20 mA
Standard: 0°C to +55°C
Isolation Voltage: ≥ 2.3 kV
Condensation Avoidance: Operates at ≤95% humidity
6RY18030-DA02
Power Interface Board
Input Voltage:+24 V DC
Optional Input Ranges: 10~30 V DC
Continuous (Logic/Control): 1–3 A
Rush (Reley Outputs): 5–10 A
Operating Temperature: 0°C to +55°C
Allocation board
C98043-A7126-L1
Control Circuit: 24 V DC ±10%
Communication: +15 V DC/-15 V DC
Screw-terminals for ≤1.5–2.5 mm² wires
Temperature: 0°C to +55°C (derating at >+40°C).
Humidity: ≤90% non-condensing