Thermocouples:Type J, K, T, etc.
RTDs:Pt100, Pt1000, etc
Analog Voltage:±10V, 0-10V
Analog Current:4-20mA
Resolution: 16-bit or higher
Sampling Rate: Up to 1 kS/s
Accuracy: ±0.1% FS (Full Scale)
Input Voltage Range:100–240V AC
DC input:24V DC
Output Voltage(s):24V DC
24V Output: 5A–10A
Total Power: 120W–250W
Voltage Regulation: ±1%
Ripple & Noise: <1% of output voltage
IMI220-411A001: 24 DI
Model Number: IMI220-411A001
Type: Digital Input Module
Number of Inputs: 24 channels
Input Voltage Range: Typically 24V DC
Input Current per Channel: 5-10 mA
Standard: 24V AC/DC ±10%
Optional: 110V AC
Power Consumption: ≤25W
Digital Inputs:24V DC
Analog Inputs:4-20mA / 0-10V
Relays Outputs:5A, 250V AC
Analog Outputs:4-20mA
RPC420 Panel Controller for each manual lever
RAM: 512MB (minimum)
Flash Storage: 4GB
2x Ethernet (10/100/1000 Mbps)
4x RS-232/RS-485 (configurable)
1x CAN bus
1x USB 2.0
Input Voltage: 24VDC
Power Consumption: 50W (typical)
Impulse withstand voltage:5 kV (1.2/50 µs)
Rated voltage:600 V
Accuracy:<0.05 % of measuring range
Nominal power consumption:2 VA
Operating altitude:≤ 2000 m
Power consumption:≤2.3 W
Rail:TS 35
Step response time:≤50 µs
Input voltage range : 18 to 30 VDC
No load on sensor side : ≤80 mA
20 mA load on sensor side : ≤120 mA
Output voltage dynamic range: 2 to 20 VDC
Output impedance : 20 Ω, protected against short-circuits
Power supply voltage rejection ratio
10 Hz to 400 Hz : ≥60 dB
400 Hz to 100 kHz : ≥30 dB
Output signal offset drift with temperature: ≤2 mV/°C
Secure M2M communication
Local logic execution
Memory:1 GB RAM + 8 GB Flash
USB:1x USB 2.0 host port
Power Supply:12-24V DC
Processor:ARM Cortex-A9 dual-core @ 1.0 GHz
links MTL8000 node to Profibus-DP host LAN
supports up to 24 I/O modules
HART process & status variables over Profibus-DP
extended diagnostics for module and channel status
LAN speeds of up to 6 Mbaud
non-volatile memory for configuration
software configurable via local port or Profibus host
HART® maintenance via Comms adaptor
Input Range: Typically ±10 V peak.
Input Range: Typically -2 V to -18 V DC
Acceleration/Velocity: DC to 10 kHz
Displacement (Eddy Current): 0 to 10 kHz
Dynamic Range: Typically > 80 dB
Voltage: Typically +15V DC
Compact with fanless design
Dual power input for avoiding power down time
Exchangeable RTC battery with easy access on the top
Digital I/O with isolation protection for sensing and controlling
Diverse system IO and supports fieldbus protocol
by idoor technology as aprotocol gateway
3G/GPS/GPRS/Wi-Fi communication by idoor technology as acommunication gateway
Supports MRAM by iDoor technology
LAN redundancy (teaming)
MPC60x 32-Bit Microprocessors
Two 32/64-Bit PMC Expansion Slots with Front-Panel and P2 I/O
64-bit PCI Expansion Mezzanine Connector
Asynchronous Serial Debug Port
Four 32-Bit Timers, One 16-Bit Timer, One Watchdog Timer
10/100Mb/s Ethernet Transceiver Interface
Display:5.7" Color TFT LCD (320 × 240 pixels)
Processor:32-bit RISC microcontroller
Power Supply:24V DC
Power Consumption:≤50W
I/O Capabilities:16–24 Digital Inputs
Miscellaneous VME / VXI Cards
Wide Range of Equipment
Analog Inputs:16–32 channels
Isolation :1500V AC
Sampling Rate:10–100 SPS
Power Supply:+24V DC (±10%)
Power Consumption:≤25W
Input Channels:8 independent
Analog Outputs:8 × 4–20mA
Output Accuracy:±0.1% FS
Isolation:1500V AC
Power Supply:24V DC (±10%),
Power Consumption:≤5W (24V DC)
Processor:32/64-bit RISC CPU
RAM: 512 MB DDR3
Flash: 1 GB
Motion:Axes Controls 4–16 servo axes
Supply Voltage:24V DC (±10%), 2A max
Power Consumption:≤25 W (peak)
Isolation:1500V AC (I/O to logic)
Power Supply:24 V DC (±15%)
CPU:32-bit RISC processor
Clock Speed:80–100 MHz
I/O Capacity:Supports up to 64 I/O modules
Optional Protocols:Modbus RTU/TCP, PROFIBUS DP
32 MHz MC68040 Microprocessor
with Floating-Point Coprocessor
8 MB DRAM
512 KB SRAM
(4) IndustryPack Ports
Ethernet Transceiver Interface
with 32-Bit Local Bus DMA
Processor:32-bit RISC CPU
Memory:2–4 MB RAM
Digital: 16–32 channels
Backplane Interface:Parallel bus
Power Requirements:+5V DC (logic)
Power Consumption:≤ 8W
Supply Voltage: 24 V DC
Power Consumption: ≤ 5 W
Isolation:1.5 kV
Power (green)
Bus activity (yellow)
Fault/error (red)
Per-port status for call stations
00 Probe not required
00 Without fittings
00 No outer sleeve, retainer, or retainingnut
03Two plugs, one 3/4-14 NPT fitting
One 3/4-14 to 1/2-14 NPT SST reducer
One cable seal grip with grommets for
the following cable sizes:
1/8 to 3/16 inches
1/4 to 5/16 inches
5/16 to 3/8 inches
02 3/4-14 NPT
30 3300 XL 8 mm probe,
with connectorprotector, multiple approvals
05 0.5 m (20 in)
15 Minimum length 1.5 in (38 mm)
031=3.1 in (78.74 mm)
03Two plugs, one 3/4-14 NPT fitting
One 3/4-14 to 1/2-14 NPT SST reducer
One cable seal grip with grommets for
the following cable sizes:
1/8 to 3/16 inches
1/4 to 5/16 inches
5/16 to 3/8 inches
02 3/4-14 NPT
Fan Type: Axial Fan
Voltage: 230V AC
Frequency: 50/60 Hz
Power Consumption: 120W
Current Consumption: 0.55A
Speed: 1400 RPM
Airflow: 2200 m³/h (1295 CFM)
Operating Temperature Range: -30°C to +60°C
Ambient Storage
Temperature Range -40°F to +176°F
Frequency 25 to 60 Hz nominal
Insulation Voltage 300 V
Manual 1601-0120-AE
Operating Temperature Range -40°F to +140°F
Measurement Principle: Guided Wave Radar
Measurement Range: Up to 30 meters (98.4 feet)
Accuracy: ±3 mm (±0.12 inches)
Resolution: 1 mm (0.04 inches)
Process Temperature Range: -196°C to 450°C (-320°F to 842°F)
Process Pressure Range: Up to 100 bar
Power Supply: 12-28 VDC
Current Consumption: Typically 20 mA
Number of outputs 16, electrically connected
Short circuit protection yes
Total current per module 8 A on 100 % duty cycle
Voltage drop ≤ 0,3 V at 0,5 A
Internal currentconsumption(from V+ bus)0 mA
External currentconsumptionLoad current
Operating mode Source operation
Voltage range 10…32 VDC, smoothed,max. 10 % residual ripple
Input Voltage: +24V DC
Operating Temperature: -10°C to +55°C.
Storage Temperature: -20°C to +70°C.
Humidity: Up to 90% RH (non-condensing)
Analog Inputs:4-20 mA