special remind
The warranty of industry automation components and parts that "amikon" 1-year warranty.
Proximity Probe HousingAssemblies
21000 aluminum probe housing assembly
28 3300 XL 8 mm probe
selectablehazardous area approvals
10 1.0 m (39 in)
No standoff adapter = 00
10.2 in (259.08) = 102
03 One 3/4-14 NPT plug
One 3/4-14 to 1/2-14 NPT reducer
One cable seal grip with grommets for
the following cable sizes:
1/8 to 3/16 inches
1/4 to 5/16 inches
5/16 to 3/8 inches
02 3/4-14 NPT
Proximity Probe HousingAssemblies
21000 aluminum probe housing assembly
16 3300 XL 8 mm probe
10 1.0 m (39 in)
No standoff adapter = 00
10.2 in (259.08) = 102
03 One 3/4-14 NPT plug
One 3/4-14 to 1/2-14 NPT reducer
One cable seal grip with grommets for
the following cable sizes:
1/8 to 3/16 inches
1/4 to 5/16 inches
5/16 to 3/8 inches
02 3/4-14 NPT
Accelerometers
Mounting Thread: 1/4-28 Female
Mounting Torque(Maximum):2 to 5 ft-lb(2.7 to 6.8 N-m)
Sensing Element :Ceramic
Sensing Geometry:Shear
Housing Material :Stainless Steel
Sealing Welded: Hermetic
Electrical Connector:2-Pin Mil-C-5015
Proximity Probe HousingAssemblies
A dome cover that screws into the body of the housing
Threaded ports for conduit connections
A probe sleeve of optional lengthl 0-rings
A reverse mount proximity probe
A thread seall Optional conduit fittings
An optional standoff adapter
Interconnect Cable
Description:Interconnect Cable (Extension Cable)
Length:30 feet (9.14 meters)
Conductor:Gauge 20 AWG stranded copper
Jacket Material:PVC (standard)
Voltage Rating:300 V AC/DC
Proximity ProbeHousing Assemblies
28 3300 XL 8mm probe
selectablehazardous area approvals
05 0.5 m (20 in)
No standoff adapter = 00
7.6 in= 076
04 One 3/4-14 NPT plug only
23/4-14 NPT
21000 Aluminum body with 304stainless steel sleeve
Proximity ProbeHousing Assemblies
dome cover that screws into the body of the housing
Threaded ports for conduit connections
probe sleeve of optional lengthl O-rings
reverse mount proximity probe
thread seall Optional conduit fittings
An optional standoff adapter
5mm / 8mm Series Proximity Transducer
Frequency Response: 0 Hz (DC) to 10 kHz
Noncontacting
Gap-to-Voltage Transducer Systems
Measures Static and Dynamic Distances
Series 10000 Proximity Probe
Operating Voltage: -18 V to -26 V DC
Sensitivity: 200 mV/mil
Linear Range: 0.08 to 0.18 inches
Frequency Response: 0 to 10 kHz
Temperature Sensitivity: ≤ ±0.15%/°C
Probe Diameter: 5 mm
Thread: M10 × 1.0 (Metric)
Proximity ProbeHousing Assemblies
00 Probe not required
00 Probe cable not required
0.4 in= 04
02 Two 3/4-14 NPT explosion-proof fittings
Proximity Probe HousingAssemblies
16 3300 XL 8 mm probe
05 0.5 m (20 in)
096 Minimum length9.6 in
00 Without fittings
02 3/4-14 NPT
8 mm Standard Mount Probe
Sensing Tip Diameter: 8 mm
Mounting Thread: 3/8-24 UNF
Unthreaded Length: 0.0 mm
Overall Case Length: 240 mm
Total Cable Length: 1.0 meter (39 inches)
Connector Type: Miniature male coaxial connector
Operating Temperature Range: -40°C to +177°C (-40°F to +350°F)
3300 NSv Proximity Probes
21000 aluminum probe housing assembly
16 3300 XL 8mm probe
05 0.5 m (20 in)
00 Without fittings
2 3/4-14 NPT
interconnect cable
Typically 50 Ohms
Operating Voltage:≤30 V DC
Proximity Probe End: BNC connector
Bend Radius: ≥10x cable
Operating: -40°C to +85°C
Storage: -50°C to +105°C
4 Meter Armored Cable
3300XL 8MM
4 Meter Armored Cable
Insulation Rating: ≥250 V AC
Bend Radius: ≥100 mm
PVC: -40°C to +105°C (-40°F to +221°F)
PUR: -40°C to +90°C (-40°F to +194°F)
Proximity Sensor
10204400281002
PROXIMITY SENSOR
MODEL: 3300 XL 8 MM
1 M LENGTH
OUTPUT RESISTANCE: 50 O
OPERATING TEMP: -51 C TO +177 C
(060-987-158)
Velomitor CT Transducer
1 0Plate Stud M6x1 to
M6x1with 3/8-in 24 adapter
Sensitivity:3.94 mV/mm/s (100 mV/in/s)±5%
Amplitude Linearity:±2% to 63.5 mm/s pk(2.5 in/s pk)
Dynamic OutputIm pedance:<400 Ω typical
Proximity Probe Housing Assemblies
A dome cover that screws into the body of the housingn
Threaded ports for conduit connectionsn
A probe sleeve of optional lengthn 0-ringsn
A reverse mount proximity proben
A thread sealn Optional conduit fittingsn
An optional standoff adapter
Velomitor CT Velocity Transducer
1 2 Plate Stud 3/8-in 24 to M8x1
0 0 MIL-C-5015 connection interface
0 1 through0 4CSA/NRTL/C (Class I, Division 1)
ATEX/IECEx/CSA (Class I, Zone0/1)
Velomitor Interconnect Cable
Signal Type:±2 V/g sensitivity range
Impedance:50–100 Ω
Capacitance: ≤100 pF/m
Temperature Range:
-40°C to +85°C (-40°F to +185°F).
Standard Interconnect Cables
2-conductor twisted
shielded 22AWG (0.5 mm2) cable
with 2-socket moisture-resistant femaleconnector at one end
terminallugs at the other end
(used withmonitors or vibration datacollectors)
Cable operating temperature is-50˚C to 120˚C
Minimum length of 2.0 ft (0.6 m)
maximum length of 99 ft (30 m)
Interconnect Cable
Capacitance: ≤100 pF/m
Temperature Range:
-40°C to +85°C (-40°F to +185°F)
Impedance:50–100 Ω
Proximitor Probe Extension Cable
EXTENSION CABLE
PROXIMITOR PROBE
075 7.5 M (295 inches)
00 Without armor
Proximitor Probe Extension Cable
EXTENSION CABLE
PROXIMITOR PROBE
075 7.5 M (295 inches)
01 Without armor