8mm Eddy Current Sensor
Linear Measurement Range 2 mm (80 mils) Initial Air Gap 0.5 mm (20 mils) Minimum Shaft Diameter 25 mm (0.79”) Operating Temperature Range Sensor incl. 1m Cable:-35 to +180°C (-31 to 356°F) Cable & Connector:-35 to +150°C (-31 to 302°F)
Mechanical velocity sensor
Sensitivity:17.5 mV/mm/s Frequency Range:14 to 1000Hz Natural Frequency:14Hz ± 7% @ 20°C (68°F) Transverse Sensitivity:< 0.1 @ 80Hz Vibration Amplitude: 500µm peak-peak Amplitude Linearity:< 2% Maximum Transverse Acceleration:2g (19.62 m/s2) Damping Factor :0.6% @ 20°C (68°F) Resistance:1723Ω ± 2% Inductance:≤ 90 mH Active Capacity:< 1.2 nF