TDB10 BOARD 400V
TDB10 Trigger/Inverter Board
Line Voltage: 380–415 V AC (3-phase)
DC Link Voltage Output:up to 575 V DC
Voltage Supply: 24 V DC ±10%
Isolation: ≥2,500 V
Input Voltage: 24 VDC
Power Tolerance: Operates within ±10%
Analog Signals: 4–20 mA or 0–10 V
Operating Temperature: -25°C to +70°C
Humidity: ≤95% non-condensing
Voltage: Typically 24 VDC (±10%)
Power Consumption: <5–10 W
Digital Inputs: 8–16 channels
Analog Inputs: 4-20 mA/0-10 V
Temperature Range: -20°C to +70°C
SIEMENS MEDL UV LAMP
WITH HEATER
Voltage (Lamp): 100–240 V AC
Power Consumption: 800 W
UV Lamp: 500–600 W
Integrated Heater: ≤200 W
UV Intensity: ≥15,000–30,000 µW/cm²
SINAMICS S120 DOUBLE MOTOR MODULE
INPUT: DC 600V
OUTPUT: 3AC 400V, 3A/3A
FRAME SIZE: BOOKSIZE D-TYPE
INTERNAL AIR COOLING OPTIMIZED PULSE SAMPLE
AND SUPPORT OF THE EXTENDED SAFETY
INTEGRATED FUNCTIONS
INCL. DRIVE-CLIQ CABLE
SINAMICS Control Unit
FS: H Supply: 24V DC 6.5A
Supply Voltage: 24 V DC
Current Consumption: 6.5 A
PROFIBUS DP: RS-485
Bandwidth: ≤100 Mbps
Pulse Frequency: Up to 100 µs
SINAMICS PERFECT HARMONY
GH180 Power cell 500A, 750V
Output Rating: 500 A at 750 V DC
Surge Capacity: ≥150%
Efficiency: ≥98.5%
DC Link Voltage: 750 V DC ±10%
Liquid Flow Rate (Coolant): 8–10 L/min
Pressure Drop: ≤2 bar at nominal flow
Perfect Harmony Medium voltage drive
PERFECT HARMONY power cell G4 Cell 200A, 750 V
Current: 200 A
Voltage (DC Link): 750 V DC
Power: 150 kW
Frequency: Up to 3 kHz
Dead-Time Compensation: <1 μs IGBT offset
Auxiliary Power Input:24 V DC
Perfect Harmony Medium voltage drive
PERFECT HARMONY power cell G4 Cell 200A, 750 V.
Current: 200 A
Voltage (DC Link): 750 V DC
Power: 150 kW
Frequency: Up to 3 kHz
Dead-Time Compensation: <1 μs IGBT offset
Auxiliary Power Input:24 V DC
Robicon G4 Power CELL, 140A, 750V
Perfect Harmony Medium voltage drive
LDZ10500424.140
Voltage (DC Link): 750 V DC ±10%
Rated Current (Continuous): 140 A
Power Rating: 105 kW
Operating Temp.: Max cell temperature ≤85°C
Capacitors: 12,000 µF ±20% 900 V DC
CPU BOARD ELECTRONIC MODULE
FOR CONVERTER
RAM ≤ 256 MB
Flash ≤ 512 MB
Digital I/O:24 VDC, ±10%
Analog Inputs: 0–10 V/4–20 mA
Input Voltage: 24 VDC ±10%
Isolation: Reinforced (3000 VAC)
Max Power Draw: 20–50 W
GEN5 VFD Power Cell
GH180 Medium Voltage Drives
Voltage Class:3.3 kV
DC Link Voltage: Standard 750 V DC
L-L Nominal:3.3 kV–6.9 kV
Continuous Output Current: 240–300 A
Processor Type: 32-bit or 64-bit RISC-based
Program Memory: 512 KB–8 MB
Data Memory: 64 KB–2 MB
Execution Speed: ~0.1–0.3 μs
Analog I/O:4–20 mA or ±10 V inputs
Voltage Rating: 24 VDC (±15%)
Power Consumption: 10–30 W
Operating Temperature: 0°C to 55°C (32°F to 131°F)
Storage Temperature: -25°C to 75°C (-13°F to 167°F)
3300 XL 11 mm Probe
M14 x 1.5 thread,without armor
10 1.0 meter (3.3 feet)
01Miniature coaxial ClickLocconnector
with connectorprotector, standard cable
05 Multiple Approvals