Function:16 AI: U, I, RTD, DI
Number of Analog Configurable I/Os:0
Analog Inputs:16
Input Signal:U, I, RTD, DI
Resolution:Analog Input 13 bit
Degree of Protection:Housing IP20
Supply Voltage:24 V DC
Ambient Air Temperature:
Operation 0 ... +60 °C
Storage -40 ... +70 °C
Supply Voltage: 24V DC (±10%), 5A max.
Atomization air pressure control
Fluid flow regulation (via PWM or analog valve)
HV electrostatic control (up to 100 kV)
Solvent purge management
Diagnostic monitoring (clogs, pressure faults)
Power Consumption: 120W (peak)
Supply Voltage: 24V DC (±10%)
Power Consumption: <10W (typical)
Voltage: ±10V, 0–5V
Current: 4–20 mA
Excitation Voltage: 24V DC
Output Type: Analog (4–20 mA)
Accuracy: ±0.1% FS
Resolution: 16-bit or higher
Bandwidth: DC to 20 kHz
SINAMICS G120 Power Module
PM 250 with integrated Class A
filter capable of energy recovery
380-480 V 3 AC +10/-10% 47-63 Hz
Power high overload: 7.5kW at 200% 3s
150% 57s, 100% 240 s
Ambient temperature 0 to +50 °C
Power low overload: 11kW at 150% 3s
110% 57s, 100% 240 s
Ambient temperature 0 to +40 °C
FSC Degree of protection
IP20 without Control Unit and BOP
Range: Typically 20.4 V DC
Series: 83SR Safety Relay System
Channel-to-Backplane/Logic: Yes
Isolation Voltage: Typically 250V AC
Safety Certification: TÜV Rheinland certified
Output Current: 105 A
Integrated Filter: L500
Frame Size: R7
Cooling Method: Air cooling
Voltage:3-phase 380–480 V AC (±10%)
Frequency:47–63 Hz
Input Current:120 A
Motor Power Range:55–75 kW
Apparent Power (S1):89 kVA (at 480 V)
Measurement Range:0–50 kN
Accuracy"±0.5% of full scale (typical)
Digital Option:RS-485 Modbus RTU
Excitation Voltage:10–30 V DC
Bridge Resistance:350 Ω ±1%
Cable Length:Standard 10m
Overload Capacity:150% of rated range
Rated Operational Voltage (Ue):230/400V AC (50/60 Hz)
Rated Insulation Voltage (Ui):500V AC
Rated Current (In):Up to 100A
Short-Circuit Capacity (Icn):10 kA
Mounting Depth:10–120 mm
Material:Galvanized steel
System Voltage:24 V DC (19.2–30 V DC)
Power Consumption:≤ 1.5 W (typical)
Communication Protocol:Profibus DP-V1
Modbus RTU (via FCI module)
Isolation:Galvanic isolation between
Input Channels:16
Input Type:Dry Contact or 24V DC Sourcing
Voltage Range:19–30 V DC
Input Current:3–5 mA per channel
Logic Levels:"1" (ON): +15–30 V DC
"0" (OFF): 0–5 V DC
Response Time:≤ 2 ms (ON/OFF)
Overvoltage Protection:60 V DC (continuous), 75 V DC (1s)
Isolation:1500 V AC
VALVE POSTITONER
ELECTROPNEUMATIC
SIPART PS 2
2/3/4 WIRE
4-20 MA
WITH HART INTERFACE
SINGLE ACTION
FOR LINEAR AND PART-TURN ACTUATORS
30 V
20 MA
18 UAUX
35 VDC
100 MA MAX