Number of inputs 16-channel, module isolation
Input current 6 mA ± 20 %
Contact rating 24 V DC +20 % / -10 %
External power supply 24 V DC +20 % / -10 %
Input response time 40 ms maximum
Withstand voltage (*1) (*2) 2 kV AC
between input signal and system for 1 minute
16-input line collectivelyconnected
Input Voltage: Typically 24V DC
Output Signals: Digital and analog signals for
motor control and feedback.
Current Consumption:100-500mA
Communication Voltage Levels: 3.3V or
5V logic levels for digital communication.
24 V DC input
Maximum current: 2 A
6.3 V DC output
Maximum current: 3.25 A
Output Power 6.3 VDC at 3.25 A
Operating Range: -40 °C to +70 °C
Storage Range: -40 °C to +85 °C
DCS880
SDCS-CON-H01
Main Control Board
Operating Voltage:24 V DC (±10%)
Current Consumption:≤1.5 A
Digital I/O Channels:32 optoisolated DC I/O points
Analog I/O:±10 V DC / 4–20 mA