Amikon Limited carry a substantial inventory of Allen Bradley PLC spares, HMI, DC Drives, Servo & Inverter Drive. We majory in supplying ControlLogix, CompactLogix, SLC, PLC-5, PanelView, PanelView Plus ,Rockwell ICS Triplex Regentand Powerflex.
Amikon Limited carry a substantial inventory of Allen Bradley PLC spares, HMI, DC Drives, Servo & Inverter Drive. We majory in supplying ControlLogix, CompactLogix, SLC, PLC-5, PanelView, PanelView Plus ,Rockwell ICS Triplex Regentand Powerflex.
Display Size:10.4 in
Manufacturer:Rockwell Automation
Product Family:PanelView Plus Operator Terminals
Operator Input:Touch
Resolution:640 x 480
Toiuchscreen:1 million presses
Input Voltage range:18-32VDC
Communication:Ethernet and RS-232
Input Power:18 to 32 VDC
Memory:64 MB
Product Type:Gas & Liquid Flow Computer
Slot(s):1
Rack Type:Local or Remote
Data Transfer Type:Ladder Logic
RAM:128 MB min
Hard Drive Space:100 MB min
Pentium PC:100 mHz or faster
Backplane Current Load:800 mA @ 5V DC
Part Number:2711P-RDB7C
Description:Display Module
Resolution:640 x 480
Display colors:18-bit color graphics
Luminance:300 cd/m2 (Nits)(3)
Input interface:Touch / Keypad
Anti-Glare overlay:not included
Touch Input:8-wire analog resistive
Resolution:640 x 480
Display colors:18-bit color graphics
Luminance:300 cd/m2 (Nits)(3)
Anti-Glare overlay:not included
Touch Input:8-wire analog resistive
Touch interface lifespan:1 Million actuations
Actuation force:10-110 g
Part Number/Catalog No.2711P-RDT7C
Series:PanelView Plus
Input:Touch
Display:7-inch Color
Part Number:2711P-RDT12C
Description:Display Module
Display Size:12.1 inches
Display Area:246 x 184 mm (9.7 x 7.2 in.)
Resolution:800 x 600
Display colors:18-bit color graphics
Luminance:300 cd/m2 (Nits)(3)
Input interface:Touch
Industrial heating systems
AC motor soft starters and speed controllers
Lighting control
Power factor correction systems
Input Voltage:100–480 V AC
Output Current:15–25 A
Gate Trigger Voltage:3–12 V DC
Gate Trigger Current:50–150 mA
Rated Blocking Voltage:4500–6500 V
Rated Average Current :1500 A
Surge Current:25–30 kA
Gate Trigger Voltage:3–5 V
Gate Trigger Current:200–500 mA
Turn-Off Time:10–30 µs
Max Junction Temperature:125–150°C
Case Temperature Range:-40°C to +80°C
Thermal Resistance:0.005–0.01°C/W.
AC Voltage:0–600 V AC
DC Voltage:0–1000 V DC
Isolation Voltage:2500 V AC
Output Signal:0–10 V DC or 4–20 mA
Accuracy:±1% full scale
Frequency Response:50/60 Hz
MICROLOGIX 1200
24V DC POWER
(20) STANDARD 24V DC AND (4) FAST 24V DC DIGITAL INPUTS
(8) RELAY OUTPUTS
(7) STANDARD 24V DC FETOUTPUTS
(1) FAST 24V DC FET OUTPUT
1762MM1
MEMORY MODULE
MICROLOGIX 1200
8K-WORD
PROGRAM & DATA BACK-UP
PROGRAM COMPARE
DATA FILE DOWNLOAD PROTECTION
WRITE PROTECTION
REMOVE/INSERT UNDER POWER
2711 PanelView Plus 6 Terminal
1500 Model, Keypad/Touch
Color, Standard Communication - Ethernet & RS-232
AC Input, Windows CE 6.0 with Extended Features
AC DRIVE
AIR COOLED
POWERFLEX 755
AC INPUT WITH PRECHARGE
IP20/IP00
OPEN TYPE
400 VAC / 540 VDC
7.5 KW / 10 HP
15.4 AMP
FILTERING
JUMPER INSTALLED
INTERNAL TRANSISTOR
AC DRIVE
AIR COOLED
POWERFLEX 755
AC INPUT WITH PRECHARGE
IP20/IP00
OPEN TYPE
400 VAC / 540 VDC
4 KW / 5 HP
8.7 AMP
FILTERING
JUMPER INSTALLED
INTERNAL TRANSISTOR
NO HIM
AC DRIVE
AIR COOLED
POWERFLEX 755
AC INPUT WITH PRECHARGE
IP20/IP00
OPEN TYPE
400 VAC / 540 VDC
4 KW / 5 HP
8.7 AMP
FILTERING
JUMPER INSTALLED
INTERNAL TRANSISTOR
NO HIM
AC DRIVE
AIR COOLED
POWERFLEX 755
AC INPUT WITH PRECHARGE
IP20/IP00
OPEN TYPE
400 VAC / 540 VDC
2.2 KW / 3 HP
5 AMP
FILTERING
JUMPER INSTALLED
INTERNAL TRANSISTOR
NO HIM
AC DRIVE
AIR COOLED
POWERFLEX 755
AC INPUT WITH PRECHARGE
IP20/IP00
OPEN TYPE
400 VAC / 540 VDC
1.5 KW / 2 HP
3.5 AMP
FILTERING
JUMPER INSTALLED
INTERNAL TRANSISTOR
NO HIM
AC DRIVE
AIR COOLED
POWERFLEX 755
AC INPUT WITH PRECHARGE
IP20/IP00
OPEN TYPE
400 VAC / 540 VDC
0.75 KW / 1.00 HP
2.1 AMP
FILTERING
JUMPER INSTALLED
INTERNAL TRANSISTOR
NO HIM
AC DRIVE
AIR COOLED
POWERFLEX 753
AC INPUT WITH PRECHARGE
IP20/IP00
OPEN TYPE
690 VAC / 932 VDC
250 KW / 335 HP
263 AMP
FILTERING
JUMPER INSTALLED
NO INTERNAL TRANSISTOR
AC DRIVE
AIR COOLED
POWERFLEX 753
AC INPUT WITH PRECHARGE
IP20/IP00
OPEN TYPE
600 VAC / 810 VDC
185 KW / 250 HP
242 AMP
FILTERING
JUMPER INSTALLED
NO INTERNAL TRANSISTOR
NO HIM
AC DRIVE
AIR COOLED
POWERFLEX 753
AC INPUT WITH PRECHARGE
IP20/IP00
OPEN TYPE
600 VAC / 810 VDC
185 KW / 250 HP
242 AMP
FILTERING
JUMPER REMOVED
NO INTERNAL TRANSISTOR
AC DRIVE
AIR COOLED
POWERFLEX 753
AC INPUT WITH PRECHARGE
IP20/IP00
OPEN TYPE
600 VAC / 810 VDC
55 KW / 75 HP
77 AMP
FILTERING
JUMPER REMOVED
INTERNAL TRANSISTOR
AC DRIVE
AIR COOLED
POWERFLEX 753
AC INPUT WITH PRECHARGE
IP20/IP00
OPEN TYPE
480 VAC / 650 VDC
300 KW / 400 HP
477 AMP
FILTERING
JUMPER INSTALLED
NO INTERNAL TRANSISTOR
NO HIM