Redundant H1 Terminal Block
Input Power Rating 35 VDC @ 500m A
AmbientTemperature-40 °C to +70 °C
Shock 10 g half-sine wave for 11 ms
Vibration 1 mm peak to peak from 2 to 13.2 Hz
0.7 g from 13.2 to 150 Hz
AirborneContaminantsISA-S71.04 –1985 Airborne
Contaminants Class G3
Relative Humidity 5 to 95% non-condensing
Fieldbus H1 Card
Local Bus Power 12 VDC at 300 mA
Fieldbus Power 9 to 32 VDC at 12 mA/Port
AmbientTemperature-40°C to +70°C
Shock 10g ½ Sinewave for 11msec
Vibration 1mm Peak to Peak from 2 to 13.2Hz;0.7g from 13.2 to 150Hz
AirborneContaminantsISA-S71.04 –1985 AirborneContaminants Class G3
Relative Humidity 5 to 95% Non-Condensing IP 20 Rating
Terminal Block keyPosition D6
Interface Terminal Block
Field Power 35 VDC at 1 A
AmbientTemperature-40°C to +70°C
Shock 10g ½ Sinewave for 11msec
Vibration 1mm Peak to Peak from 2 to 13.2Hz;0.7g from 13.2 to 150Hz
AirborneContaminantsISA-S71.04 –1985 AirborneContaminants Class G3
Relative Humidity 5 to 95% Non-Condensing
Terminal Block Key Position Set according to I/O card installed
Serial Interface Module
SERIAL INTERFACE CARD
12 VDC
300 MA
2 PORT
D4 TERMINAL BLOCK KEY POSITION
Simplex SIC (Serial Interface Card),
LocalBus Power Rating 12 VDC 300mA
Ambient Temperature -40 to 70 degrees C
Digital Input Module
Input Channels:32
Galvanic Isolation: 1500 VAC RMS or ±1500 VDC
Isolation Technique:Optical (in IOM)
DI Power Voltage Range:18 to 30 VDC
ON Sense Voltage/Current:13 VDC (min) or 3 mA (min)
OFF Sense Voltage/Current:5 VDC (max) or 1.2 mA (max)
nput Impedance:4.2 K
Absolute Delay Across Input Filter and Isolation:5 ms ± 20%
Power Supply Board
Model: SDCS-POW-H01
Part Number: 3ADT318700R1501
Application: Dedicated power supply unit
Input Voltage Nominal: 24 V DC
Range: 20–30 V DC
AC Input Option: support 100–240 V AC (50/60 Hz)
Primary Output: 24 V DC
Continuous: 5–10 A
Peak Current: Up to 15 A
Excitation plate
Model: SDCS-FEX-4a
Part Number: 3ADT314500R1501
Input Voltage Nominal: 24 V DC
Range: 20–30 V DC
Voltage Range: 0–250 V DC
Current Capacity: Up to 20–50 A
Continuous Output Power: ~5–10 kW
Reference Input: 0–10 V DC or 4–20 mA
DCSLink communication options board
Supply Voltage Nominal: 24 V DC
Supply Voltage Range: 20–30 V DC
Power Consumption:Typically <5 W
Operating Temperature: -25°C to +70°C (-13°F to +158°F).
Storage Temperature: -40°C to +85°C (-40°F to +185°F).
Humidity: 5–95% RH (non-condensing).
FIRING PULSE TRANSFORMER BOARD
Model: SDCS-PIN-H41
Part Number: 3ADT320600R1501
Pulse Voltage: 5–24 V DC
Isolated Pulse Voltage: Typically 10–30 V
Output Current: 1–2 A
Primary-to-Secondary Isolation: ≥2500 V AC
Insulation Resistance: >100 MΩ
Power supply board
Model: SDCS-PIN-H51
Order Code/Part Number: 3ADT320700R1501
Nominal Input Voltage: 24 V DC
Input Voltage Range: 20–30 V DC
Primary Output: 24 V DC
Output Current: Typically 2–5 A
Continuous Power: ~60–120 W
Typically ≥85%

Copyright Notice © 2004-2024 amikong.com All rights reserved
Disclaimer: We are not an authorized distributor or distributor of the product manufacturer of this website, The product may have older date codes or be an older series than that available direct from the factory or authorized dealers. Because our company is not an authorized distributor of this product, the Original Manufacturer’s warranty does not apply.While many DCS PLC products will have firmware already installed, Our company makes no representation as to whether a DSC PLC product will or will not have firmware and, if it does have firmware, whether the firmware is the revision level that you need for your application. Our company also makes no representations as to your ability or right to download or otherwise obtain firmware for the product from our company, its distributors, or any other source. Our company also makes no representations as to your right to install any such firmware on the product. Our company will not obtain or supply firmware on your behalf. It is your obligation to comply with the terms of any End-User License Agreement or similar document related to obtaining or installing firmware.