Product Type : Standard 8mm Probe
Standard 8mm Probe : M10×1; without armor
Probe Type : 07
Unthreaded Length : 00 = 0 mm
Case Length : 04 = 40 mm
Total Length : 10 = 1.0 m
Connect or Type : 02 = Yes
Power Supply Voltage:24 VDC nominal
Output Signal:4-20 mA
Frequency Response:10 Hz to 10 kHz (-3 dB)
Gain Accuracy:±1% of full scale
Operating Temperature:
-40°C to +85°C (-40°F to +185°F)
Storage Temperature:
-50°C to +90°C (-58°F to +194°F)
Power Supply Voltage:24 VDC nominal
Power Consumption:≤ 3 W
Analog Output:4-20 mA
Frequency Response:10 Hz to 1 kHz (-3 dB)
Operating Temperature:
-40°C to +85°C (-40°F to +185°F)
Storage Temperature:
-50°C to +90°C (-58°F to +194°F)
Power Supply Voltage:24 VDC nominal
Power Consumption:≤ 5 W
Analog Output:4-20 mA
Frequency Response:2 Hz to 10 kHz (-3 dB)
Operating Temperature:-20°C to +70°C (-4°F to +158°F)
Storage Temperature:-40°C to +85°C (-40°F to +185°F)
Power Supply Voltage:24 VDC nominal
Power Consumption:≤ 5 W
Analog Output:4-20 mA
Frequency Response:2 Hz to 10 kHz (-3 dB)
Operating Temperature:-20°C to +70°C (-4°F to +158°F)
Storage Temperature:-40°C to +85°C (-40°F to +185°F)
Power Supply Voltage:24 VDC (nominal), ±10%
Power Consumption:≤ 5 W
Current Output:4-20 mA
Frequency Response:0.5 Hz to 10 kHz (-3 dB)
Operating Temperature:
-20°C to +70°C (-4°F to +158°F)
Storage Temperature:
-40°C to +85°C (-40°F to +185°F)
Power Supply:Voltage: -23 to -30VDC
Sensitivity:3.94 mV/um (100mV/mil)
Linear Range:
4.0mm (160mils)
begins at 0.40mm (16mils)
fromprobe surface (AISI4140)
Range is 0.40 - 4.40mm (16 - 173 mils)
Frequency Response (±3db):0 - 3.0 kHz
Power Supply Voltage:
24 VDC (nominal), with ±10% tolerance
Power Consumption:≤ 10 W
Signal Input Channels:4 to 16 channels
Vibration: 4-20 mA or 0-5 VDC.
Proximity Probe: -24 VDC signal bias.
Temperature: RTD or Thermocouple
Power Supply: 3-phase 380-480V AC, 50/60 Hz
Output Voltage: Adjustable from 0 to input voltage
Output Frequency Range: 0 to 320 Hz
Rated Power: 22 kW
Current Rating: 47.5 A
Input Voltage Range:24 V DC or 110 V AC/DC
Relay Contacts:1 A to 5 A,
Operating Temperature Range:-20°C to +70°C
Storage Temperature Range:-40°C to +85°C
Input Voltage Range:24 V DC or 110 V AC/DC
Relay Contacts:1 A to 5 A,
Operating Temperature Range:-20°C to +70°C
Storage Temperature Range:-40°C to +85°C
Input Voltage Range: 24 V DC
Number of Inputs: 32 discrete inputs
Operating Voltage: 24 V DC
Operating Temperature: -20°C to +60°C
Storage Temperature: -40°C to +85°C
Humidity Range: Typically 5% to 95%
Input Voltage: 24V DC (nominal)
Power Consumption: Typically 10W
Operating Temperature: -15°C to +55°C
Storage Temperature: -40°C to +70°C
Humidity: 0 to 95% RH, non-condensing
Powermonitor 3000
Master Module with
3-Phase metering & setpoints & I/O
Data logging
5 Amps, Control Power
120V/240V AC 50/60- Hz or
125V/250V DC
Revenue metering
compliance to 1% Accuracy
I/O module:16 digital inputs 24 VDC in 4 groups
Status indicators:I/O function per channel
Operation:0 to 60°C
Storage:-25 to 70°C
Nominal voltage:24 VDC
Hardware:≤12 ms
Switchable displaysk
Text or bar graph displayk
8 limit comparatorsk
4 setpointsk
2 parameter setsk
Maths and logic modulek
Ramp and profile program function
Concept:Transparent Ready
Port Ethernet:10/100BASE-TX - 8 port(s) copper cable
Supply voltage limits:9.6…32 V DC SELV
Power consumption in W:6 W
Alarm output:1 voltfree contact 1 A
Ambient air temperature for operation:0…60 °C
rated supply voltage:12...24 V
Load cell supply 5 V alternating current supply
Input signal 0 15 mV
Sensitivity 0.6 μV / d
Unit kg, g, t, lb, N, kN
Linearity error <0.05 ‰ / 10 K
Range stability,TKc<0.04 ‰ / 10 K
Power Supply:Typically 5 to 24 VDC
Current Consumption:Typical: 40 mA
Operating Temperature:
-10°C to +70°C (14°F to 158°F)
Storage Temperature:
-20°C to +85°C (-4°F to 185°F)
Input Voltage:110/220 VAC or 24 VDC
Frequency Range:50 Hz or 60 Hz
Frequency: ±10%
Operating Temperature:-10°C to +60°C (14°F to 140°F)
Storage Temperature:-40°C to +85°C (-40°F to +185°F)
Humidity:5–95% RH
Input Voltage Range: 0–30 VDC
Output Voltage Range: 0–30 VDC
Output Current: Up to 2 A per channel
Input Voltage: 24 VDC ±10%
Power Consumption: ≤10 W
Operating Temperature: -40°C to +85°C
Storage Temperature: -55°C to +100°C
Humidity: 5–95% RH
Power Supply: 24 VAC/DC ±10%, 50/60 Hz
Rated voltage: 250 VAC
Maximum current: 8 A
Operating Temperature: -10°C to +60°C
Storage Temperature: -20°C to +70°C
Humidity: 10% to 90% RH
Power supply 24 VDC (12 to 35 V)
Output signal 4 to 20 mA / 2-wire
Load 0 to 1000 Ohm (35 V)
Accuracy Thermocouple at 25 °C ±2 °C (ITS-90)
Output shift by ambient temperature ±0.005 %
Operating ambient temperature -40 to +125 °C
Chipset type:Intel 945GME at 533 MHz
Display size:15 inch
Display colour:16 million colours
Luminance:350 cd/m²
Supply voltage limits:85…265 V
Inrush current:40 A
Power consumption in W:130 W
Material:Treated steel
Voltage:Standard 500 V DC
Accuracy: ±5% of reading
Operating Temperature:Typically -10°C to +55°C
Storage Temperature:-20°C to +70°C
Relative Humidity:10% to 95%, non-condensing
Input Voltage:24 V DC or 230 V AC
Single-phase supply 230V +10%/-1
Frequency 50/60
Control signal 0 to 10V
Power supply for possible manual control (+V terminal) 20 Vdc 40
Input Voltage:230 VAC ± 10%, 50/60 Hz
Operating Temperature:0°C to +50°C
Storage Temperature: -20°C to +70°C
Relative Humidity:10% to 90% RH, non-condensing.
Power Supply Voltage:24 VDC
Analog Input Channel :4 channels per module
Analog Input Range: ±10V
Digital Data Range :±2000
Resolution :12 bits (1LSB=5 mV)
Input Impedance :200 KΩ and above
Response Time: 3 ms × channels
Absolution Input Range :±15 V
Analog Output Range: 0~10V
Digital Data Range :0~4000
Temperature Range: Typically -50°C to 300°C
Accuracy: ±0.1°C
Input Voltage: 100-240 VAC, 50/60 Hz
Output Type:4-20 mA or 0-10 V
Operating Temperature Range: Typically -10°C to +60°C
Storage Temperature Range: Typically -20°C to +70°C
Housing design (light emission) Cylindrical
Housing length 70.2 mm
Thread diameter (housing) M18 x 1
Optical axis Axial
Sensing range max. 0.05 m ... 7 m
Sensing range 0.05 m ... 6 m
Type of light Visible red light
Light source LED
Adjustment Potentiometer, 270
Operating temperature range: 0...+ 100°C
Operating frequency range: 0...15 kHz (-3dB)
Displacement measuring range: 2,15 mm
Sensitivity: 7,87 V/mm (200 mV/mil)
Mean voltage: -10,00 V
Power supply: -24 V nominal
Standard cable: 4 - core (4 x 0,2 mm2)
Operating Voltage:120/230 V AC
Current Rating :16 A
Power Output :1.6 kW
Communication Interface:Profibus DP
Control Signals:Up to 16 digital inputs and outputs
Temperature Range:-25°C to 55°C
SIMATIC S7-1500
Analog I/O modules
Fully modular connection
Connection module
at DC / rated value 24 V
rated value 50 V
at DC / maximum 50 V
current / rated value 1 A
during operation 0 ... 60 °C
during storage -40 ... +70 °C
SIMATIC S7-1500
mounting rail 245 mm (approx. 9.6 inch)
incl. grounding screw
integrated DIN rail for mounting of
incidentals such as terminals
automatic circuit breakers and relays
SIMATIC S7-1500
CPU 1511-1 PN
central processing unit with work
memory 300 KB for program
and 1.5 MB for data, 1st interface
PROFINET IRT with 2-port switch
25 ns bit performance
SIMATIC Memory Card
Product type designation DQ 8x24VDC/2A HF
HW functional status FS03
Firmware version V2.2.0
Rated value (DC) 24 V
permissible range, lower limit (DC) 19.2 V
permissible range, upper limit (DC) 28.8 V
Current consumption, max. 40 mA
Rated value (DC) 24 V
Power available from the backplane bus 0.9 W
SIMATIC S7-1500 Analog input module
AI 8xU/I/R/RTD BA
16 bit resolution,Accuracy 0.5%, 8 channels in groups of 8
Common mode voltage 4 V DC,Diagnostics
Hardware interrupts; Delivery including infeed element
shield bracketand shield terminal
Front connector (screw terminals or push-in)
to be orderedseparately
Product specific application:Complex machines
Format of the drive:Compact
Mounting mode:Wall mount
rated supply voltage:380...500 V - 15...10 %
Nominal output current:5.5 A
Motor power kW:2.2 kW for heavy duty
Discrete input number:7
Transient overtorque:170…200 % of nominal motor torque
Power supply:24 V DC (-15%/+20%)
NOVRAM:128 kB
Max. power consumption:27 W
Weight:approx. 1165 g
Dimensions (W x H x D):144 mm x 99 mm x 91 mm
Relative humidity:95%, no condensation
Operating/storage temperature:-25…+60°C/-40…+85°C
Control Cycle Time: 62.5 µs
Encoder Frequency: Up to 10 MHz
Voltage: 5V DC (from PCI bus)
Current Consumption: Typically < 1A
Operating Temperature: 0°C to 45°C
Humidity: 5% to 90% non-condensing
Storage Temperature: -20°C to 70°C
For liquid flow: 0.5 to 10,000 l/h
For gas flow: 1 to 1000 Nm³/h
Accuracy: Typically ± 1%
Analog Outputs:4-20 mA output
Operating Temperature:Typically -20°C to 60°C
Storage Temperature:Typically -20°C to 80°C
Headers & Wire Housings
NANO-FIT TPA V0 BLK 3 CKT
Product:Accessories
Number of Positions:3 Position
Pitch:2.5 mm (0.098 in)
Tradename:Nano-Fit
Minimum Operating Temperature:- 40 C
Maximum Operating Temperature:+ 115 C
Product:Switching Supplies
Input Type:1-Phase / Single Phase
Output Power: 240 W
Number of Outputs: 1 Output
Output Voltage-Channel 1:24 V
Output Current-Channel 1:10 A
Isolation Voltage:3 kVAC
Maximum Operating Temperature: + 70 C
Minimum Operating Temperature:- 40 C
Switching Capacity: 32 Gbps
Forwarding Rate: 23.8 Mpps
MAC Address Table: 8K entries
Jumbo Frame Support: Yes (up to 9KB)
VLAN: Supports up to 256 VLANs
Power Supply Voltage: 12-48 VDC
Power Consumption: 20 W (typical)
Operating Temperature:-40°C to +75°C (-40°F to +167°F)
Storage Temperature:-40°C to +85°C (-40°F to +185°F)
Function: ESB Bus optical transport function
Connection method: Star type connection
Chain type connection
Available for both star and chain type connection.
Number of connecting stage: Maximum two
Transmission distance: Maximum 5 km (total two stages)
In case of Vnet/IP system with the R1.03 or later,
the total distance of two stagesis maximum 10 km.
Current consumption: 0.5 A
Number of output channels 8 channels, module isolation
Rated output range 4 to 20 mA
Maximum range of guaranteed precision 1.25 to 23 mA
Output range 1.25 to 23 mA
Allowable load resistance @ rated range 230 to 600 Ω
Accuracy ±48 µA
Data update frequency 40 ms
Temperature drift ±16 µA/10 ºC
Withstand voltage 1.5 kV AC between output signal and system for 1 minute
Number of outputs 8-channel, module isolation
Output voltage 24 V DC
Output voltage drop 1 V maximum
External power supply rating 24 V DC, 5 A minimum
External power supply 24 V DC +20 %/–10 %
Output format Current source
Maximum load current 0.6 A/output line
Minimum load current 35 mA
Load resistance range 40 to 685 Ω
Output response time 30 ms maximum
Number of outputs 8-channel, module isolation
Output voltage 24 V DC
Output voltage drop 1 V maximum
External power supply rating 24 V DC, 5 A minimum
External power supply 24 V DC +20 %/–10 %
Output format Current source
Maximum load current 0.6 A/output line
Minimum load current 35 mA
Load resistance range 40 to 685 Ω
Output response time 30 ms maximum
Number of outputs 4-channel, module isolation
Output voltage 24 V DC
Output voltage drop 1 V maximum
External power supply rating 24 V DC, 10 A minimum
External power supply 24 V DC +20 %/–10 %
Maximum leak current at output offstatus 1.6 mA
Output format Current source
Maximum load current 2 A/output line
Minimum load current 100 mA
Load resistance range 12 to 240 Ω)
Maximum lamp load (*1) 1 A/output line
Number of outputs 8-channel, module isolation
Output voltage 24 V DC
Output voltage drop 1 V maximum
External power supply rating 24 V DC, 5 A minimum
Maximum leak current at output offstatus 1.6 mA
Output format Current source
Maximum load current 0.6 A/output line
Minimum load current 35 mA
Load resistance range 40 to 685 Ω
Output response time 30 ms maximum
Number of inputs 16-channel, module isolation
Input current 6 mA ± 20 %
Contact rating 24 V DC +20 % / -10 %
External power supply 24 V DC +20 % / -10 %
Input response time 40 ms maximum
Withstand voltage (*1) (*2) 2 kV AC between input signal and system for 1 minute, 16-input line collectivelyconnected
Number of input channels 16 channels, module isolation
Rated input range 4 to 20 mA
Permissible input range 0 to 25 mA
Input impedance during Power-OFF 500 kΩ minimum
Data update frequency 40 ms
Temperature drift ±16 µA/10 °C
Withstand voltage 1.5 kV AC between input signal and system for 1 minute
Number of input channels 16 channels, module isolation
Rated input range 4 to 20 mA
Input impedance during Power-OFF 500 kΩ minimum
Data update frequency 40 ms
Temperature drift ±16 µA/10 °C
Withstand voltage 1.5 kV AC between input signal and system for 1 minute
Number of outputs 8-channel, module isolation
Output voltage 24 V DC
Output voltage drop 1 V maximum
External power supply rating 24 V DC, 5 A minimum
Maximum leak current at output offstatus 1.6 mA
Output format Current source
Minimum load current 35 mA
Load resistance range 40 to 685 Ω
Output response time 30 ms maximum
Number of outputs 4-channel, module isolation
Output voltage 24 V DC
Output voltage drop 1 V maximum
External power supply rating 24 V DC, 10 A minimum
Output format Current source
Maximum load current 2 A/output line (8 A in total output lines) (*4)
Minimum load current 100 mA
Load resistance range 12 to 240 Ω (*6)
Analog Inputs:0-10V or 4-20m
Digital Outputs:24V DC
Analog Outputs: 0-10V or 4-20mA
Power Supply:24V DC
Digital Inputs: Typically 8 or 16 digital inputs
Operation method:Unipolar constant current drive
Applied Motor:2-phase stepper motor
Resolution:Intelligent type
Power supply:24-35VDC
Max. Run Current:2A/Phase
Max. Current Consumption:3A
Number Of Axes:1-axis
Environment_Ambient temperature:0 to 50℃, storage: -10 to 60℃
Environment_Ambient humidity:35 to 85% RH, storage: 35 to 85% RH
Dynalco Part No.: LMD-120D
Description: Current Loop-Powered Digital Indicator
Input Signal: 4–20 mA or 10–50 mA, jumper-selectable
Loop Burden: 2 volts maximum, i.e. 100 Ohms at 20 mA
Display: 3½ digits standard;
4½ digits with fixed zero at right-most digit.
Selectable decimal point.
Span and zero adjust:
25-turn potentiometers permit span adjustment from
100 up to 2000 units, and zero adjustment
from – 1000 up to +1000 units
Accuracy: 0.1% linearity,
0.5% stability over the environmental range
User memory:10 megabytes
Safety memory:5 megabytes
Digital I/O / Analog I/O:128,000 / 4000 max
Ethernet performance:10/100/1000 megabits per second
Current draw at 1.2 Volts DC:5.0 milli Amps
Current draw at 5.1 Volts DC:1.2 Amps
Input Voltage:24V DC
Input Current:10-20 mA
Signal Input Range:0-24V DC
Input Channels:8 or 16
Operating Temperature:-10°C to +60°C
Storage Temperature:-40°C to +85°C
Input Voltage:24V DC
Input Current:10-20 mA
Signal Input Range:0-24V DC
Input Channels:8 or 16
Operating Temperature:-10°C to +60°C
Storage Temperature:-40°C to +85°C
Input Voltage:24V DC
Current Consumption:Typically 100-200 mA
Fieldbus Power:24V DC
Operating Temperature:Typically -10°C to +60°C
Storage Temperature:-40°C to +85°C
Communication profile CiA 301
Number of installed NFLC121 modules 4 max. for FCN-500
Number of slave devices 126 slave devices per
CANopen Communication Module
Node Bootup
SYNC producer
Heartbeat Consumer/Producer
Number of output channels 16
Rated applied voltage 24 to 125 V DC
100 to 240 V AC, 50/60 Hz
Output response time 12 ms or less
Maximum current consumption 780 mA (5 V DC)
External connection Pressure clamp terminal
Number of input channels 8, isolated channels
Input signal (*1) Contact ON/OFF, voltage pulse
Input frequency 0.1 Hz to 10 kHz
Frequency accuracy 0.1% of reading
Minimum input pulse width 40 μs
Shunt resistance Select from OFF/1000 Ω
Pull-up resistance 68 kΩ (12 V DC or 24 V DC)
Data refresh cycle 10ms
Maximum current consumption 300 mA (5 V DC), 400 mA (24 V DC)
100 to 120 V AC
Duplex configuration: Possible
Hot-Swap: Possible
Rated output: +5.1 V DC, 7.8 A
Analog field power supply: Input: 24 V DC ±10 %, 4 A,
Duplexed (matching-diode)• LED: SYS
(5 V system power output ON)
FLD (24 V field power supply ON)
Checking terminals: +5 V, +24 V
Transmission method Serial communication
Baud rate 128 Mbps
Transmission distance Max. 8 m per line
Extension units Max. 2 units
Duplex configuration Possible
Supplyvoltage 5 V DC±5%
Currentdissipation Max. 500 mA
Rated input voltage:220 to 240 V AC
Input voltage range:170 to 264 V AC (rms)
Input frequency:47 to 66 Hz (Rating: 50/60 Hz)
Input current: Max. 0.7 A
Fuse rating:3.15 A
Leak current Max. :1 mA
Withstanding voltage:3000 V AC for 1 minute
Insulation resistance:50 MΩ at 500 V DC
Input signal 4 to 20 mA
Allowable input current 24 mA
Accuracy ±0.1% of full scale
Overcurrent protection Provided
Data refresh cycle 10 ms
Input step response time 100 ms
Temperature drift Max. ±0.01%/°C
Operation -40 to +70 °C
Transportation/storage -40 to +85 °C
Dust 0.3 mg/m3 or less
Protection class IP20
Altitude 3000 m or less
Electric field 3 V/m or less (26 MHz to 1 GH