Number of I/O channels
8-channel input, isolated channels
I/O signal 4 to 20 mA
Allowable input current 25 mA
Accuracy ±16 µA
Data update period 10 ms
Temperature drift ±16 µA/10 °C
Maximum currentconsumption
360 mA (5 V DC), 450 mA (24 V DC)
SIMATIC DP
ELECTRONIC MODULE
ET200S: 2AI HIGH SPEED I2WIRE
0 - 20MA, 4 - 20MA, 15BIT
15 MM WIDTH,FOR 2-WIRE
TRANSDUCER,CYCLE TIME OF
THE MOD.: 0.1MS,
WITH LED SF (GROUP FAULT)
High-Speed 1 MS/s 16-bit Isolation Module
(4 ch) High Noise Immunity
Suitable for testing and long-term monitoring
for power generators and multi-output power supplies.
Provides dynamic analysis of multi-channel
data recording applications.
Applicable to DL350 and DL850 series
FREQUENCY RANGE:45 Hz to 65 Hz
VOLTAGE RANGE:90 V to 305 V (L-N)
DC OUTPUT:5 A DC 12 V DC
RIPPLE AND NOISE:<1%
EFFICIENCY:>80%
LINE:<0.001% Vo
LOAD:1% Vo
AC SUPPLY VOLTAGE RANGE
90 V to 250 V (L-N)
DC OUTPUT
5 A DC 12 V DC at 13.7 V DC
RIPPLE AND NOISE:<1%
EFFICIENCY:>80%
REGULATION LINE:<0.001% Vo
LOAD:1% Vo
CONTINUOUS VOLTAGE RATING
8 V to 35 V continuous
CRANKING DROPOUTS
Able to survive 0 V for 50 mS,
providing supply was at least 10 V
before dropout and supply recovers to 5 V.
This is achieved without the need for internal batteries
MAXIMUM OPERATING CURRENT
460 mA at 12 V, 245 mA at 24 V
MAXIMUM STANDBY CURRENT
375 mA at 12 V, 200 mA at 24 V
CHARGE FAIL/EXCITATION RANGE
0 V to 35 V
CONTINUOUS VOLTAGE RATING
5 V to 35 V continuous
CRANKING DROPOUTS
Able to survive 0 V for 100 mS,
providing supply was at least 10 V
before dropout and supply recovers to 5 V.
This is achieved without the need for internal batteries
MAXIMUM OPERATING CURRENT
530 mA at 12 V, 280 mA at 24 V
MAXIMUM STANDBY CURRENT
320 mA at 12 V, 160 mA at 24 V
CHARGE FAIL/EXCITATION RANGE
0 V to 35 V
Synchronising & Load Sharing Auto Start Control Module
CONTINUOUS VOLTAGE RATING
8 V to 35 V continuous
CRANKING DROPOUTS
Able to survive 0 V for 50 mS,
providing supply was at least 10 V
before dropout and supply recovers to 5 V.
This is achieved without the need for internal batteries
MAXIMUM OPERATING CURRENT
460 mA at 12 V, 245 mA at 24 V
MAXIMUM STANDBY CURRENT
375 mA at 12 V, 200 mA at 24 V
CHARGE FAIL/EXCITATION RANGE
0 V to 35 V
CONTINUOUS VOLTAGE RATING
8 V to 35 V Continuous
Able to survive 0 V for 50 mS
providing supply was at least 10 V
before dropout and supply recovers to 5 V
This is achieved without the need for internal batteries
LEDs and backlight will not be maintained during cranking
MAXIMUM OPERATING CURRENT
85 mA at 12 V, 96 mA at 24 V
MAXIMUM STANDBY CURRENT
51 mA at 12 V, 47 mA at 24 V
Able to survive 0 V for 50 mS
providing supply was at least 10 V
efore dropout and supply recovers to 5 V
This is achieved without the need for internal batteries.
LEDs and backlight will not be maintained during cranking
CONTINUOUS VOLTAGE RATING
8 V to 35 V Continuous
MAXIMUM OPERATING CURRENT
85 mA at 12 V, 96 mA at 24 V
MAXIMUM STANDBY CURRENT
51 mA at 12 V, 47 mA at 24 V
MAXIMUM SLEEP CURRENT
35 mA at 12 V, 32 mA at 24 V
MAXIMUM DEEP SLEEP CURRENT
<10 uA at 12 V, <10 uA at 24 V
CONTINUOUS VOLTAGE RATING
8 V to 35 V Continuous
5 V for up to 1 Minute
CRANKING DROPOUTS
Able to survive 0 V for 100 mS,
providing supply was at least 10 V
before dropout and supply recovers to 5 V.
This is achieved without the need for internal batteries
MAXIMUM OPERATING CURRENT
510 mA at 12 V, 240 mA at 24 V
MAXIMUM STANDBY CURRENT
330 mA at 12 V, 160 mA at 24 V
CHARGE FAIL/EXCITATION RANGE
0 V to 35 V
CONTINUOUS VOLTAGE RATING
8 V to 35 V Continuous
5 V for up to 1 minute
MAXIMUM OPERATING CURRENT
510 mA at 12 V, 240 mA at 24 V
MAXIMUM STANDBY CURRENT
330 mA at 12 V, 160 mA at 24 V
CHARGE FAIL/EXCITATION RANGE
0 V to 35 V
Operating Voltage Range: 8 V to 35 V
Cranking Dropout:
Able to withstand 0 V for 50 ms,
provided the supply was at least 10 V
before the dropout and recovers to 5 V
afterward. No internal battery is required.
Maximum Operating Current:
100 mA at 12 V, 105 mA at 24 V
Maximum Standby Current:
60 mA at 12 V, 55 mA at 24 V
Maximum Sleep Current:
40 mA at 12 V, 35 mA at 24 V
DSE 6120 MKII is an
Auto Mains (Utility) Failure Control Module
developed to provide a wide range of
operating and monitoring features for
single diesel and gas gen-sets
Back-lit icon LCD display
Front panel editing
LED and LCD alarm indication
Power Save mode
CAN and Magnetic Pick-up/Alt.
versions available (specify on
ordering)
PC configurable
6 Digital inputs
4 Outputs (2 configurable on
Magnetic Pick up/Alt., 4 configurable on CAN version)
Configurable timers and alarms
Alternative configuration
Remote Start input
Generator voltage display
suitability for use Swappable lens with C-mount connection
suitability for operation lens for MV440
mechanical datacolor black
design, dimensions and weight
sheight 37.2 mm
diameter 29.5 mm
120 Volts Doubler Mode:Yes
Continuous Output Current (0-peak):5.7 Amperes
Integrated AC (EMC) Line Filter:No
Input Voltage:120/240 Volts (AC), 1 Phase
Power Rating:800 W
Part Number/Catalog No.:2097-V31PR2-LM
Safe Torque-Off:Yes
Module Width:Single Slot
Compatible controllers:SLC 5/02 or later
Pass through:Supported
Communication Port:One (1) DeviceNet
Data Transfer speed:125Kbps
Storage Temperature:-40 to 85 C (-40 to 185 F)
Vibration:Tested 5 g @ 10-500Hz per IEC 68-2-6
Operating Shock:30 g peak acceleration, 11(+1)ms pulse width
Series:SLC 500
Module Type:DeviceNet Scanner Module
Scan I/O:Yes
Backplane Current (5 Volts):500 milliamps
PROCESS MODULE
XM-360
6-CHANNEL INPUT
0-10 VDC/0-20 MA INPUT RANGE
4-20 MA OUTPUT
600 OHM MAX LOAD
STATUS INDICATORS
RS-02232 VIA MINI-CONNECTOR
COMM RATE FIXED @ 19.2 KBPS
STANDARD DEVICENET NETWORK