Module Type:Digital DC Output Module
Number of Outputs:32 (4 sets of 8) Outputs
Voltage Category:10-32 Volts DC, Sink
DC Operating Voltage:10-30 Volts
Backplane Current:330 Miliamperes
Max Continuous Current Per Output:0.5 Amperes
Max Continuous Current Per Module:8 Amperes
Wiring Arm:1771-WH
Coating:Conformal Coat
Typical AC Signal Delay (Off):45 (+/- 15) ms
Series:PACSystem RX3i
Product Description:DeviceNet Master Module
Part Number:IC694DNM200
Communication protocol:DeviceNet
Maximum Number of Slave Devices Supported:63
No. of supported DeviceNet slave:63
Slave Operation:Supported
Input data:255 Bytes
Communication Rates:125k, 250k, or 500k bauds
Output data:255 Bytes
Input Types:4 V, C, or 3 TC, or 2 RTD, Resistance
Resolution:18 bits
Input Overvoltage Protection:+24 VDC continuous
Input Overcurrent Protection:32 mA continuous
Backplane Current Required:15 mA at 5 V maximum 20 mA at 24 V maximum
Common Mode Rejection:<96 dB at 50/60 Hz
Normal Mode Rejection:65 dB to 74 dB at 50/60 Hz
Thermal Dissipation:1.00 Watt, maximum
Input Types:4 V, C, or 3 TC, or 2 RTD, Resistance
Resolution:18 bits
Input Overvoltage Protection:+24 VDC continuous
Input Overcurrent Protection:32 mA continuous
Backplane Current Required:15 mA at 5 V maximum 20 mA at 24 V maximum
Common Mode Rejection:<96 dB at 50/60 Hz
Normal Mode Rejection:65 dB to 74 dB at 50/60 Hz
Thermal Dissipation:1.00 Watt, maximum
I/O Capacity:8
Communication Rate:5 Mbps
Output Power:5.4 Volts DC
Power Supply:9.5 Volts DC
Power Consumption:8.5 W
Power Dissipation:8.5 W
Thermal Dissipation:29 BTU/hour
SCALANCE XB205-3LD
managed layer 2 IE switch
5x 10/100 Mbit/s RJ45 ports
3x SM FO SC-port 1x console port,
diagnostics LED redundant power supply
IEC62443-4-2 certified
temperature range 0 °C to +60 °C
DIN-rail mounting; defaultPROFINET
Configurable high-pass and low-pass filters
Frequency range: 0.5 Hz to 20 kHz
Optional integrator to produce a velocity output
Optional 2-wire current or 3-wire voltagetransmission
Certified for use in potentially explosiveatmospheres
A range of installation options are available
Configurable high-pass and low-pass filters
Frequency range: 0.5 Hz to 20 kHz
Optional integrator to produce a velocity output
Optional 2-wire current or 3-wire voltagetransmission
Certified for use in potentially explosiveatmospheres
A range of installation options are available
Model Number: 51196694-350/U1
AID-3 9395-00379-034/B
Key Layout: 101 keys, including a numeric keypad.
Cable Length: 3 meters.
Compatibility: Designed for use with
Honeywell industrial control systems
Product Type:FLEX Ex RTD Thermocouple I/O Module
Inputs:8
Input Type:Internal Bus Configurable
Signal Input Range:40 to 100 millivolts
Lead Resistance Compensation:15 Watts maximum
Settling Time:8 milliseconds
Module Field-side Power Consumption:1.6 Watts
Power Dissipation:1.6 Watts
Thermal Dissipation:5.46 BTU/hour maximum
Power Supply:9.5 Volts DC
IE/PB link PN IO
gateway between Industrial Ethernet and PROFIBUS
PROFINET IO proxy with real-time communication
time-of-day synchronization viaSIMATIC processes
NTP, SNMP v1, LLDP
S7 routing, data record routing
connection of up to 64 S7/DPV0/DPV1 slaves
support of DP/PA link and DP/FFlink
10/100 Mbit/s fast Ethernet, MRP
9.6 Kbit/s up to 12 Mbit/s PROFIBUS
firmware loading via configuration tool
redundant power supply
firmware versionV4.0.
Diode Matrix: -10V> +10V
Current measurements: 4-20mA
Temperature measurements: NTC probe
Operating temperature -20 to +70˚C (-4 to 158˚F)
Storage temperature -40 to +85˚C (-40 to 185˚F)
ON state Voltage, min:6VDC
ON state Voltage, max.26.4VDC
ON state Voltage, nom:24VDC
Enclosure:Open-type
Operating Temperature:0 to 55 C (32 to 131 F)
Storage Temperature:-40 to 85 C (-40 to 185 F)
Vibration: 5g @ 10 to 500 Hz
Operating Shock:30 g
Product Type:Flex I/O 4 Channel Pulse Counter Module
Inputs:2 per Interface
Pulse Counter Interfaces:4