Measurement Range: +/- 50 mils (1.27 mm)
Frequency Range: DC to 10 kHz
Output Signal: 4-20 mA
Power Supply: 24 VDC nominal, 18-32 VDC
Temperature Range: -40°C to +85°C
3300 NSv Probe, M10X1 thread, witharmor
Order in increments of 10 mm.
Metric thread configurations:
Maximum length: 250 mm
Minimum length: 20 mm
Example: 06 = 60 mm
Example: 0 4 = 0.4 in.
10 1.0 meter (39 in)
02 Miniature coaxial ClickLoc connector,standard cable
CN Multiple Approvals
3300 XL 8 mm Probe, 3/8-24 UNFthread, with armor
Order in increments of 0.1 in.Length configurations:
Maximum unthreaded length: 8.8 in.
Minimum unthreaded length: 0.0 in.
Example: 0 4 = 0.4 in.
10 1.0 meter (3.3 feet)
11 Miniature coaxial ClickLocconnector with connectorprotector, FluidLoc cable
00 Not required
01 19-inch Rack (14 module slots)
02 Rack Mount Option, Full-Size Rack
(mounts to19-inch EIA Rack)
01 CSA/NRTL/C (Class 1, Division 2)
00 None
01 CE
The 3500/05 mini-rack is not available
in theBulkhead Mount option.
Accepts from 1 to 16 signals
Input impedance: Greater than 1 MΩ
Power consumption: 3 watts
Front panel LEDs: OK, TX/RX, Bypass
Type E, J, K, T thermocouples
100 Ω 3-wire and 4-wire platinum RTD
Local or Remote Visual Indication
of 3500 Machinery Protection System
(4) Display Mounting Types
Up to (2) Displays per 3500 Rack
Input Signal: -10 Vdc to +10 Vdc
Power Consumption: 10.5 watts
Ethernet: 100Base-FX Fiber-Optic
Power Consumption:4.75 watts, typical
Standard:RS232 serial communications
Data Rate:38.4 k baud
Normally closed contacts:Arc suppressors are provided
Maximum Current:<1 mA dc, Dry Contact to Common
Signal :Accepts from 1 to 4 proximitytransducer signals
Power consumption :7.7 Watts, typical
Standard I/O: 10 kΩ
Output Impedance:550 Ω
Transducer Power Supply:-24 Vdc
Gap filter:-3 dB at 0.09 Hz
Smax : 0.125 to 15.8 times runningspeed
System Event List
Alarm Event List
All module and channel data
3300 style rack view (API-670)
Current alarm data (quick view)
Nine custom display options
7 0 7.0 metres (23.0 feet)
0 2 Bulkhead screws
0 1 CSA Division 2
Power : Requires +12 to +35 Vdc
input at the transmitter terminal.
Maximum Loop Resistance :
1,000 Ω including cable at 35 Vdc.
Current Limiting : 23 mA typical.
7 0 7.0 metres (23.0 feet)
0 1 35 mm DIN rail clips
0 1 CSA Division 2
Power : Requires +12 to +35 Vdc
input at the transmitter terminal.
Maximum Loop Resistance :
1,000 Ω including cable at 35 Vdc.
Current Limiting : 23 mA typical
5 0 5.0 metres (16.4 feet)
0 2 Bulkhead screws
0 1 CSA Division 2
Power : Requires +12 to +35 Vdc
input at the transmitter terminal.
Maximum Loop Resistance :
1,000 Ω including cable at 35 Vdc.
Current Limiting : 23 mA typical.
5 0 5.0 metres (16.4 feet)
0 2 Bulkhead screws
0 0 Not required
Power : Requires +12 to +35 Vdc
input at the transmitter terminal.
Maximum Loop Resistance :
1,000 Ω including cable at 35 Vdc.
Current Limiting : 23 mA typical.
5 0 5.0 metres (16.4 feet)
0 1 35 mm DIN rail clips
0 5 CSA Division 2, ATEX Zone 0,
ATEXZone 2 and includes ABS maritimeapprova
Power : Requires +12 to +35 Vdc
input at the transmitter terminal.
Maximum Loop Resistance :
1,000 Ω including cable at 35 Vdc.
Current Limiting : 23 mA typical.
5 0 5.0 metres (16.4 feet)
0 1 35 mm DIN rail clips
0 1 CSA Division 2
Power : Requires +12 to +35 Vdc
input at the transmitter terminal.
Maximum Loop Resistance :
1,000 Ω including cable at 35 Vdc.
Current Limiting : 23 mA typical.
0 1 35 mm DIN rail clips
CN CSA Division 2, ATEX Zone 0,
ATEXZone 2 and includes ABS maritimeapproval
Power : Requires +12 to +35 Vdc
input at the transmitter terminal.
Maximum Loop Resistance :
1,000 Ω including cable at 35 Vdc.
Current Limiting : 23 mA typical.
0 4 0-4 mils pp (0-100 μm pp)
5 0 5.0 metres (16.4 feet)
0 1 35 mm DIN rail clips
0 5 CSA Division 2, ATEX Zone 0,
ATEXZone 2 and includes
ABS maritimeapproval
Power : Requires +12 to +35 Vdc
input at the transmitter terminal.
Maximum Loop Resistance :
1,000 Ω including cable at 35 Vdc.
Current Limiting : 23 mA typical.
Sensitivity 3.94 mV/mm/s (100 mV/in/s)±5%.
TemperatureSensitivity-8% to +5%
AmplitudeLinearity±2% to 63.5 mm/s pk
MountedResonantFrequency9 kHz, minimum
DynamicOutputImpedance<400 Ω typical
BroadbandNoise Floor 0.229 mm/s (0.009 in/s) pk.
OperatingTemperature-40 °C to +85 °C
StorageTemperature-40 °C to +100 °C
Shock Limit 5000 g pk, maximum.
HumidityLimit100% condensing
3300 XL 8 mm Probe
M10 x 1 thread
with armor
10 1.0 meter (3.3 feet)
01Miniature coaxial ClickLocconnector with connectorprotector,
standard cable
00 Not required
Order in increments of 10 mm
Length configurations:
Maximum unthreaded length: 230 mm
Minimum unthreaded length: 0 mm
Example: 0 6 = 60 mm
7200 5mm / 8mm Series
Proximity Transducer Systems
Frequency Response:
0 Hz (DC) to 10 kHz
Noncontacting
Gap-to-Voltage Transducer Systems
Measures Static and Dynamic Distances
3300 XL 8 mm Probe
3/8-24 UNFthread
with armor
05 0.5 meter (1.6 feet)
02 Miniature coaxial ClickLocconnector,
standard cable
05 CSA, ATEX, IECEx Approvals
Order in increments of 0.1 in.
Length configurations:
Maximum unthreaded length: 8.8 in.
Minimum unthreaded length: 0.0 in.
Example: 0 4 = 0.4 in.