Analog Outputs: 4–20 mA
Voltage: 12–24 V DC
Consumption: ≤5 W
Drive Coil Excitation: 10–50 V AC
Standard: -40°C to +70°C (-40°F to +158°F)
Humidity: 0–95% RH (non-condensing)
Analog Inputs: 4–8 channels
Analog Outputs: 4–20 mA or ±10 V DC
Digital I/O: 24 V DC
Form Factor: 6U VME module
Operating Temperature: -20°C to +70°C (-4°F to +158°F)
Humidity: 5–95% RH (non-condensing).
System: Mark VI Turbine Control System
Clock Speed: ≥1 GHz
RAM: 1–2 GB DDR3
Flash Storage: 4–8 GB
Form Factor: 6U VME module
Voltage: 24 V DC (±10%)
Power Consumption: ≤25 W
Analog: 4–20 mA, ±10 V DC
Digital: 24 V DC dry/wet contacts
Frequency: Vibration signals
Form Factor: 6U VME module
Data Acquisition:16-bit ADC resolution
Sampling rates up to 50 kS/s
Backplane: VME P1/J1 connectors for bus communication
Signal termination for 4–20 mA
Current: 4–20 mA
Voltage: 0–10 V DC, ±5 V DC
Temperature: RTD (Pt100/1000)
Cable Length: 10 meters (indicated by "-10" suffix)
Bend Radius: ≥8x cable diameter
Operating Temperature: -40°C to +105°C (-40°F to +221°F)
Number of Channels: 8 or 16
Current: 4–20 mA
Voltage: 0–10 V DC, ±10 V DC
Channel-to-channel: ≥250 V AC
Field-to-system: 1500 V AC
Supply Voltage: 24 V DC (±10%)
Power Consumption: ≤5 W
ABB infi-90 Termination Loop Cable
Gauge: 18–24 AWG
Voltage Rating: ≤60 V DC
Operating Temperature: -20°C to +70°C (-4°F to +158°F)
Humidity: 5–95% RH (non-condensing)
Voltage: 24 V DC (±10%)
Power Consumption: ≤10 W (typical)
Isolation: 1500 V AC
Operating Temperature: -40°C to +70°C (-40°F to +158°F)
Storage Temperature: -50°C to +85°C (-58°F to +185°F)
Humidity: 5–95% RH (non-condensing)
Space requirements:4 TE, 3 HE (= 4 HP, 3U)
current: max. 10 mA (WD1in + WD2in)
Number of outputs:18
power requirements:100 mA
current: + 5V_load of all (18) IO boards
+ WD_load of all (18) IO boards
voltage drop:0.2V < V < 0.8V
C-plug
removable data storage medium
For simple device replacement in case offault,
for recording configuration or engineering and application data
can be usedin the following
SIMATIC NET products with C-plug
slot: SCALANCE XC-200,
XP200, XM-400, XR-500,
M-800, W-700, SC-600 and S615
MICROMASTER 440 without filter
380-480 V 3 AC +10/-10% 47-63 Hz
constant torque 0.37 kW overload 150% 60 s
200% 3 s square-law torque 0.37 kW
protection IP20 ambient
temperature -10+50 °C without AOP/BOP
Voltage Feedback: 0–500 V DC
Current Feedback: 0–10 A DC
Accuracy: ±0.25% of full scale
Frequency Response: Up to 100 Hz
Signal-to-System Isolation: 1500 V AC
Common-Mode Rejection: >60 dB at 50/60 Hz
Analog Output: 4–20 mA or 0–10 V DC
3300 XL 11 mm Probe
M14 x 1.5 thread,without armor
10 1.0 meter (3.3 feet)
01Miniature coaxial ClickLocconnector
with connectorprotector, standard cable
00 Not required
3300XL 8MM
4 Meter Armored Cable
Insulation Rating: ≥250 V AC
Bend Radius: ≥100 mm
PVC: -40°C to +105°C (-40°F to +221°F)
PUR: -40°C to +90°C (-40°F to +194°F)
Fast Scan (Priority I/O Module Scan)
Electronic short circuit protection
Safe-state (FAILOPT) behaviors configurable
on aper channel basis for Digital / Analog Output
HART 7 support (analog IO)
Extended Temperature Range -40 to +70°Cmodule ambient
Primary/Secondary Inputs: Dual 24 V DC (±20% range)
Voltage: 24 V DC (regulated, ±1%)
Per Module: 5 A continuous (10 A peak)
Redundant Capacity: 15 A total
Efficiency: ≥85% (typical load)
Ripple/Noise: <100 mV peak-to-peak
Occupies one slot in the I/O chassis
Two isolated RS-422 serial
ports for remote multiplexed I/O
Analog Input: 4–20 mA, 0–10 V DC, RTD (Pt100)
Analog Output: 4–20 mA, 0–10 V DC
Channels: 16–32 multiplexed channels
Scan Rate: <10 ms per channel
Analog: 16-bit ADC/DAC
Channel-to-channel: 250 V AC
Input Voltage: 24 V DC ±10%
Sixteen input points
Hot-replaceable
Complete, automatic testing of all input circuits
Automatic line monitoring detects
open and short field wiringfaults
2500 volt minimum electrical
isolation between field and logiccircuits
1751SLBA
SYNCHLINK BASE BLOCK
CONVERTS SYNCHLINK TO ELECTRICAL SIGNALS
TO INTERFACE UP TO 4 FIBER 4-PORT SPLITTER BLOCKS
1.2 AMP
600 MA
24 VDC
OPEN STYLE
MOUNTABLE
1444RELX0004RB
EXPANSION RELAY MODULE
4 SINGLE POLE DOUBLE THROW RELAYS
CONNECT UP TO THREE TO
ONE 1444-DYN04-01RA
DYNAMIC MEASUREMENTMODULE.
REQUIRES 1444-TB-B BASE
AND 1444-REL-RPC- CONNECTOR SET
Current consumption:1110 mA 5 V DC
Module format:Double
Operating altitude:0...6561.68 ft (0...2000 m)
Protective treatment:TC
Analogue I/O processor:80 I/O
Discrete I/O processor:1024 I/O
Concept:Transparent Ready
Software Designation:PL7 Junior/Pro
Display Size:10.4 in
Manufacturer:Rockwell Automation
Product Family:PanelView Plus Operator Terminals
Operator Input:Touch
Resolution:640 x 480
Toiuchscreen:1 million presses
Input Voltage range:18-32VDC
Communication:Ethernet and RS-232
Input Power:18 to 32 VDC
Memory:64 MB
Relay:SPDT, rated 5 A @ 250 V AC
Solid-State Relay (SSR) Driver:12 V DC, 30 mA
Analog Output:0–10 V DC or 4–20 mA
Accuracy: ±0.2% of full scale
Display Type: Backlit LED or LCD
Voltage: 100–240 V AC
Power Consumption: ≤ 5 W
Input Voltage: 24 V DC
Range: 18–32 V DC
Power Consumption: Typically ≤ 10 W
Isolation Voltage: 1500 V AC
Serial Ports: RS-232/RS-485 (configurable).
Ethernet: 10/100 Mbps RJ45 (TCP/IP)
Operating Temperature: -40°C to +70°C (-40°F to +158°F)
Storage Temperature: -50°C to +85°C (-58°F to +185°F)
Software designation:PL7 Junior/Pro
Number of racks:6 4/6/8 slots;8 12 slots
Discrete I/O processor:1024 I/O
Number of application specific channel:32
Current consumption:1360 mA at 5 V DC
Module format:Double
Operating altitude:0...2000 m
Input Voltage: 24 V DC
Input Range: 10–30 V DC
Number of Input Points: 32 points
Input Current: 3–5 mA per point
Isolation: 1500 V AC
Backplane Power: 5 V DC
Field Power: External 24 V DC supply for I/O
Input Delay: ≤ 1 ms
Extensive internal diagnostics for data integrity
NO Open wire detection
Optional redundancy
On board excitation power
Supplies Non-incendive field power
Direct / Reverse Input Indication
Galvanic isolation
Internal or external field power selection
SIMATIC S7-1500
Analog input module AI 8xU/I HS
16 bit resolution,
Accuracy 0.3% 8 channels in groups of 8
Common mode voltage 10 V
Diagnostics; Hardware interrupts 8 channels in 0.0625 ms Oversampling;
Delivery including infeed element