SINAMICS S120
Double Motor Module
input: 600 V DC
output: 400V 3AC, 18 A/18 A
design: booksize D type
internal air cooling optimized pulse patterns
and support of the extended Safety Integrated
functions incl. DRIVE-CLiQ cable
SINAMICS S120/S150
Logic-side (control): 24 V DC
Power-side (IGBT control):up to 800 V DC peak
Signal Isolation: ≥2500 V AC
Operating: 0°C to +55°C
Storage: -40°C to +85°C
Light and cost-effective plastic housing
suitable for continuous 24/7 operation
178°H/178°V extra-wide viewing angle
High fidelity digital processing
8ms fast response time
Support multiple signal inputs
such as HDMI, VGA and USB
Physical button
infrared remote dual control mode
SINAMICS S120
SINGLE MOTOR MODULE
INPUT: DC 600V
OUTPUT: 3-PH 400V, 9A
FRAME SIZE: BOOKSIZE D-TYPE
INTERNAL AIR COOLING OPTIMIZED PULSE
SAMPLE AND SUPPORT OF THE EXTENDED
SAFETY INTEGRATED FUNCTIONS
INCL. DRIVE-CLIQ CABLE
Two-conductor 18 AWGtwisted, shielded cable
withright angle two-socket plugat one end
terminal lugs atthe other end.
Used withmonitors and with 21128Velocity
Transducer Housing
Min. length: 2.0 ft (0.6 m)
Max. length: 99 ft (30 m)
330104 3300 XL 8 mm Probe
M10 x 1 thread,with armor
10 1.0 meter (3.3 feet)
01Miniature coaxial ClickLocconnector
with connectorprotector, standard cable
00 Not required
Clock Speed: 800 MHz – 1.5 GHz
RAM: 2 GB DDR4
Operating Voltage: 24 V DC
Power Consumption: ≤18 W
Isolation: ≥3000 V AC
Ethernet Interfaces:2× Gigabit ports
Discrete I/O: 12–24 V DC
Analog Interfaces: 4–8 channels
Operating Voltage: 24 V DC
Power Consumption: <12 W
Input Protection:±40 V peak transient
Digital I/O: 16 channels
Analog I/O (Optional): 4 channels
Ethernet: 2× 10/100 Mbps ports
Serial: RS-232/RS-485 for legacy devices
Fieldbus: PROFIBUS DP
68295505
System Voltage:380–500V AC
Frequency Range:10–20 kHz
Filter Topology:LC filters (inductors + capacitors)
Operating Temperature:-15°C to +50°C
ACS880 Liquid-Cooled Multi-Drives
ACS600 Single Drives
VARISTOR UNIT
Protects ACS600 single drives
Protection DutyAC Input Line Transients
Voltage Rating:380–500V AC (50/60 Hz)
Energy Absorption:≥ 120 joules
Clamping Voltage:1.3–1.5x V
Maximum Continuous Voltage:550 V DC link
SINAMICS S120
SINGLE MOTOR MODULE
INPUT: DC 600V
OUTPUT: 3AC 400V,
30A FRAME SIZE: BOOKSIZE C-TYPE
INTERNAL AIR COOLING OPTIMIZED
PULSE SAMPLE AND SUPPORT OF
THE EXTENDED SAFETY INTEGRATED FUNCTIONS
INCL. DRIVE-CLIQ CABLE
Input Power: 24V DC
Sensor Interfaces: Analog I/O (0-10V/4-20mA)
ARM/X86-based chipsets
Temperature Range: -20°C to +60°C
Humidity Tolerance: ≤95% (non-condensing)
SINAMICS S120 Motor Modules
DC Link Voltage: voltages up to 600–900V
Logic Power Supply: 24V DC ±10%
Real-time IGBT driver control
Operating Temp.: -10°C to +50°C
SINAMICS S120
Adapter cable 4-pole
for connection of the connector X41
for replacement of the CIB module
with a Control Interface Module (CIM)
is only required for air-cooled Power Modules
Inverter Control Board
Input Control Signals:0–10 V or 4–20 mA
Power Regulation: 600–1200 V DC link
Current Handling:50–100 A
Switching frequency range: 1–6 kHz
Operating Temperature: 0–60°C
MEMORY UNIT KIT
AINF6 3.42 +ZMU-03 SP
Signal Compatibility: 4–20 mA, 0–10 V, ±10 V
Resolution: 16-bit precision
Storage Capacity:2–32 GB
Analog Input Module (AINF6): 24 V DC (±10%)
Voltage Range:300–500 V AC
3AUA0000031096
ACS800 Main Board
frequency converter communication board
Auxiliary Power Input: 24 V DC (±10%)
Power Consumption: ≤5 W (typical)
Digital I/O:24 V DC
Analog Inputs: 0–10 V or 4–20 mA
ACS600 Fiber-optic communication board
MAIN CIRCUIT INTERFACE BOARD
GIVES CONTROL COMMANDS
SENDS MEASUREMENT SIGNALS
Number: Up to 16 channels
Connectors: ST/SC-type
Isolation Voltage: 2500 V
PCB MATCHING BOARD
CIRCUIT BOARD MODULE
58908096
Operating Voltage: 24 V DC (±10%)
Power Consumption: <5 W
Analog: +/-10 V DC or 4–20 mA
Digital: 24 V DI/DO