SIMOTRAS HD Snubber circuit
Rated Voltage (Unm): 690 V AC (50/60 Hz)
Operating Voltage Range: 200–750 V AC
Capacitance: 10–50 μF
Impedance Range: 5–50 Ω at 50 Hz
Dielectric Strength: 2.5 kV AC
INVERTER MOTHERBOARD
FOR ACS580
3AXD50000716975
Input Voltage Range:380–500V AC (3-phase)
DC Bus Link:Integrated protection
Control Voltage:24V DC
Logic Board Power:Switch-mode PSU
Communication Isolation:1500V AC reinforced
Operating Temp:-15°C to +45°C
Input Voltage:380–690V AC
Output Power:up to 630 kW
Control Voltage:24V DC (±10%)
Ambient Operation:-15°C to +50°C
Humidity Protection:<95% non-condensing
CE Mark: Low Voltage Directive
Digital I/O: 6 programmable DI
Analog I/O: 2x 0–10V/4–20mA
Input Power (AC):400–690V (±10%) 3-phase
Motor Power Range:250kW–1.5MW
Control Voltage:Single-phase 26V DC to 30V DC (±15%)
Operating Temp:-15°C to +50°C
Harsh Environment:UL 1203
Busbar Terminals:values 8.9Nm ±0.5
AS-Interface Safety ATEX Gateway
Input Voltage:200–690V AC (-15%/+10%)
Power Range:15–400kW
Control Voltage:Single-phase 24V DC
Relay Outputs:4 × Form-A
AF-650PG: Profibus DP or CANopen
Low Voltage (LV): 380–480V AC
Optional High Voltage (HV):500–690V AC
Short-Circuit Current Rating (I_SC): ≤100 kA
Inrush Current Limit: ≤150% × rated input current
Isolation: ≥2.5 kV
Dynamic braking fuses:690V AC, 100–800A
Ambient Temp Range: -15°C to +45°C
Storage Humidity: ≤95% non-condensing
Points:32, commoned
Nominal input voltage:24 V DC
Operational voltage range:15–30 V DC
Absolute maximum input voltage:33 V DC
Absolute maximum reverse input voltage:–0.6 V DC
Input delay:<10 ms, On to Off or Off to On
ADC scan time:<1 ms for all 32 points
Points:16, commoned
Nominal output voltage:24 V DC
Operational voltage range:15–30 V DC
Absolute maximum output voltage:33 V DC
Absolute maximum reverse input voltage:–0.6 V DC
Leakage to load (Off-state):<1 mA
On-state voltage drop:<1 V DC @ 1.5 A
Loop-back scan time:<1 ms for all 16 points
Points:32, commoned
Nominal input current:4–20 mA DC
Operational current range:2–22 mA DC
Absolute maximum field voltage:33 V DC
Absolute maximum input current:50 mA DC
Input bandwidth (3dB):16 Hz
Source impedance:180 Ω
Resolution:12 bits
Absolute error:0.15% of full scale (20 mA)
Diagnostic:Force-to-value diagnostic (FVD)
Scan time:<1 ms for all 32 points
Offers a distance-to-spot ratio of 50:1
Works with most K-type thermocouples
Allows easy access to advanced features
with soft-key buttons and graphical display
Captures up to 99 points of data for
quick downloading to a PC through the USB connection
Quickly identifies problems with MIN, MAX, AVG, and DIF functions
Easily adapts to lighting conditions with a two-level backlight
R8 SINGLE MODULE SP KIT
Forward Voltage: 1200–2500V range
Average On-State Current:500–2000A
Surge Current :10–50 kA
Isolation: ≥2000 V AC
Junction Temperature:>125°C
Supply Voltage:24V DC
Analog Inputs: 0–10 V / 4–20 mA
Communication Ports: Terminals for RS-485
Isolation Rating: ≥1500 V AC
Power Handling: 5-10A
Operating Temperature: -25°C to +70°C
DC Link Voltage Range: 380–525V/690V DC
Current Capacity:50–500 kW
Switching Components:high-power IGBT module
Gate Driver Outputs: 2–16 kHz
Isolation: 2.5 kV
Protocol Support:24V DC signals
Temperature: -10°C to +80°C
Humidity: <95% RH non-condensing
DC Link:1200V
Continuous: 1400A
Pulsed Current: 2000–2800A
Frequency: ≤5 kHz typical
Max. withstand voltage of 1800V
Typical Motor Load: 500–2000 HP induction motors
Voltage Class:1200V
Continuous Current : 650A
Maximum Current: Up to 1300A
Collector-Emitter Saturation Voltage : 2.0–3.0V
Isolation: ≥2500 V DC
Thermal Resistance <0.1°C/W
Voltage: +15V/-8V gate control
Operating Temperature: -40°C to +125°C
DBV / dBm measurement
1 μV resolution in DC mV range
Current measurement 20 A
(30 seconds momentary, 10 A continuous)
Peak capture function to record transients as fast as 250 μs
Continuity / Conductance / Capacitance
Resistance and continuity
Duty cycle & pulse width measurement
Min / Max / Average with Time Stamp to record signal fluctuations
Real time and elapsed time modes
CAT III 1000 V / CAT IV 600 V safety rated
Number of inputchannels:8, isolated channels
Input frequency :0 to 10 kHz
Minimum input pulse width:40 µs
Pull-up resistance:68 kΩ (12 V DC or 24 V DC)
Filter:Filter for eliminating chattering can be set
Data update period:2 ms
EC401 ESB Bus Coupler Module
5 Standard type with no explosion protection
E Standard type with explosion protection
0 Basic type
1 With ISA Standard G3 option
Function: ESB bus interface function
Number of connectable units: Max. 9 units (*1)
Transmission speed: 128 Mbps
Transmission distance: Max. 10 m
Current consumption: 0.5 A
EC402 ESB Bus Coupler Module
5 Standard type with no explosion protection
E Standard type with explosion protection
0 Basic type
1 With ISA Standard G3 option
Actuator Compatibility:spring-return actuators
Supply Pressure Range: 3–30 psi
Input Signal: 4–20 mA
Port Sizes: 1/4" NPT or G1/4 threaded ports
Temperature Range: -40°C to +85°C (-40°F to +185°F)
Ability to de-energizel
Ability to de-energize via secondary meansl
Cross talk between outputsl
Function of the suppression diodesl
Lead breakage in the (external) output wiringl
Short circuit of the outputs
Sensitivity:3.94 mV/mm/s (100 mV/in/s)±5%.
FrequencyResponse:3.0 Hz to 900 Hz (180 to 54,000cpm) ±1.0 dB
TemperatureSensitivity:-8% to +5% typical over theoperating temperature range
TransverseResponse:Less than 5% of the axialsensitivity.
Output BiasVoltage:10.1 Vdc ± 1.0 Vdc, Pin Areferenced to Pin B
Points:32, commoned
Nominal input current:4–20 mA DC
Operational current range:2–22 mA DC
Absolute maximum field voltage:33 V DC
Absolute maximum reverse field voltage:– 0.6 V DC
Absolute maximum input current:50 mA DC
Input bandwidth (3dB):16 Hz
Source impedance:180 Ω
Resolution:12 bits
Absolute error:0.15% of full scale (20 mA)
Diagnostic:Force-to-value diagnostic (FVD)
Points:32, commoned
Nominal input voltage:24 V DC
Operational voltage range:15–30 V DC
Absolute maximum input voltage:33 V DC
Absolute maximum reverse input voltage:–0.6 V DC
Input delay:<10 ms, On to Off or Off to On
ADC scan time:<1 ms for all 32 points
Points:16, commoned
Nominal output voltage:24 VDC
Specified operational voltage range:15 to 30 VDC
Absolute maximum output voltage:33 VDC
Absolute maximum reverse input voltage:– 0.6 VDC
Leakage to load (Off state):<1 mA
Diagnostic glitch duration <2 ms, maximum:500 Ps, typical
On state voltage drop:<1.0 VDC @ 1.5 A