MICROMASTER 440
without filter 380-480 V
3 AC +10/-10% 47-63 Hz
constant torque 22 kW
overload 150% 60 s, 200%
3 s square-law torque 30 kW
520x 275x 245 (HxWxD)
degree of protection IP20
ambient temperature -10+50 °C
without AOP/BOP
Component Type: Modular Power Cell
Nominal DC Voltage: 1,000–1,700 VDC
Input Current:50–200 A
AC Output Per Cell:690–1140V AC
Switching Frequency: 0–60 Hz
Insulation Testing: Rated for 5–15 kV
Legacy Status: Sinamics SL150
Robicon A5E39206479
DEV CONTROL SIMATIC HMI
Screen Size:8.4-inch
Brightness:300–400 cd/m²
Power Supply:24 VDC
Power Range: +15%/-20%
Operating: 0–55°C
Storage: -30°C to +70°C
Line monitored digital input
Non line monitored digital input
Line monitored ESD input (on Channel 32)
Analog input 0-20mA or 4-20mA
Digital output (0.5 Amp) configurable line monitoring
Multiple digital output (1 Amp or 2 Amp)
with or without line monitoring
Analog output 0-20mA or 4-20mA
330101 3300 XL 8 mm Probe,
3/8-24 UNFthread, without armor
05 0.5 meter (1.6 feet)
02 Miniature coaxial ClickLocconnector
standard cable
00 Not required
28 3300 XL 8 mm probe, multiple approvals
05 0.5 m (20 in)
08 Minimum length 80 mm
080 Minimum length 80 mm
03Two plugs, one M20 fitting
One cable seal grip with grommets forarmored probe cable
02 3/4-14 NPT
28 3300 XL 8 mm probe, multiple approvals
05 0.5 m (20 in)
15 Minimum length 150 mm
080 Minimum length 80 mm
03Two plugs, one M20 fitting
One cable seal grip with grommets forarmored probe cable
02 3/4-14 NPT
SIMOTICS S
synchronous servo motor
1FT6 27 Nm, 100K, 2000 rpm naturally cooled
IP65 IM B5 (IM V1, IM V3)
incremental encoder sin/cos
1 VSS 2048 S/R (encoder I-2048)
for power/signal connectors:
Outlet direction axial DE without holding brake
SINAMICS G120 CONTROL UNIT
CU250S-2 DPINTEGRIERT PROFIBUS
SUPPORT OF VECTORCONTROL
EASY POSITIONING EPOS VIAEXTENDED
FUNCTION LICENSE 4 CONFIGURABLEDI/DO
6 DI (3 F-DI), 5 DI, 3 DO (1 F-DO), 2 AI
2 AOSAFETY INTEGRATED STO, SBC
SS1 FURTHERSAFETY FUNCTIONS VIA EXTENDED
SAFETYLICENSE ENCODER: D-CLIQ + HTL/TTL/SSI
RESOLVER/HTL VIA TERMINAL PROTECTION
IP20USB- AND SD/MMC-INTERFACE
Voltage Rating:400 V AC – 600 V AC
Resistor: 10Ω–200Ω
Power Dissipation: ≥250W
Current Handling:5–50 A transient pulses
Operating Temperature: -25°C to +60°C
Humidity Tolerance: ≤90% non-condensing
AC Line Supply: 3-phase 380–480 V AC
DC Output: 520–650 V DC
Rated Current:18–30 A
Output Power: 15–110 kW
Efficiency: ≥97%
Storage temperature: -25°C to +70°C
Humidity: ≤85% non-condensing
contactor AC-1, 140 A, 690 V
40 °C, 3-pole, 480 V AC, 60 Hz
auxiliary contacts: 2 NO + 2 NC
main circuit: ring cable lug connection,
control and auxiliary circuit: screw terminal
size: S3
COMMUNICATION MODULE
CBC
FOR CAN-BUS COMMS
SPARE PART
SIMOVERT MASTERDRIVES
Isolation: up to 500 V
Supply Voltage: Pulls 24 V DC
Process Data (PZD): 4–6 PZD
Temperature: 0°C – +55°C
TDB MODULE PC BOARD
690VAC
FOR CONVERTER MODULE
3-phase AC Voltage: 690 V AC(±10%)
Frequency Tolerance: ±5%
Isolation Voltage: 2000 V AC
Operating Temperature:-25°C to +55°C
control electronics Standard incl.
terminals C98043-A7100-L1
Primary Supply (Logic): 24 V DC ±10%
Current Handling (Logic): ≤5 A
Analog signal inputs:±10 V, 4–20 mA
Operating: 0°C to +40°C (full rating).
Extended: Optional derating up to +60°C
Humidity: ≤85% (non-condensing)
Input Voltage: 24 V DC
Voltage Range: +15 V to -10 V
Current Capacity: 5–10 A
Switching Frequency: Up to 20 kHz
Galvanic Isolation Voltage: ≥2500 V AC
Operating Temperature: -20°C to +55°C
Storage Temperature: -40°C to +85°C
Control Voltage: 24 V DC
Signal Voltage: 5 V/3.3 V
Switching Frequency:12–16 kHz
Current Ratings:55–160 kW
Overload Capacity: Typically 150%
Temperature: –10°C to +40°C
Humidity: ≤90% (non-condensing)
Trigger Voltage/Current:+15 V/-10 V
Switching Frequency: Up to 20 kHz
Isolation Voltage: ≥2000 V AC
Logic Supply: +24 V DC (±10%)
Gate Driver Supply: ±15 V DC
Operating Temperature: 0–55°C
Power Supply (Control Section): 24 V DC (±20%)
DC Link Voltage Handling:500–800 V DC
Motor Compatibility: up to 100s of kW
Switching Frequency: 2–16 kHz
Digital Inputs/Outputs:≥6 DI/DO
Analog Inputs:≥2 × ±10 V, 4–20 mA
Operating Temperature: 0–45°C
Voltage Range: 3-phase AC input
Frequency: 50/60 Hz (±5%)
DC Link voltage:510–720 V DC
Continuous Current (DC Link): Up to 60–80 A
Auxiliary Voltage Supply: 24 V DC
Aambient Temperature: 0–40°C
Supply Voltage: 24 V DC (±20%)
Power Consumption: ≤15 W
Motor Compatibility: up to 55 kW
Standard Communication:PROFIBUS DP
Operating Temperature: -20°C to +60°C.
Relative Humidity: ≤95% (non-condensing)
Voltage Range:380–480 V AC
Frequency: 50/60 Hz ±5%
Rated Current:20–200 A
Continuous Power: 10–150 kW
Operating Temperature: -10°C to +50°C (storage up to +70°C)
DIGITAL INPUT MODULE
32 CHANNEL
24 VDC
ISOLATED
50 MA
PULSE WIDTH OUTPUT FUNCTION
TIME-PROPORTIONAL OUTPUT FUNCTION
STATUS DISPLAY
NO EXPLOSION PROTECTION
Number of input channels:64
Rated input voltage:24 V DC
Input ON voltage:20 to 26.4 V DC
Input OFF voltage :5.0 V DC or less
Input current :2.5 mA±20 % / channel
Maximum allowable input voltage:30.0 V DC
Input response time :8 ms or less
Minimum ON detection time:20 ms
Maximum ON/OFF cycle:25 Hz
Maximum current consumption:500 mA (5 V DC)
EC402 ESB Bus Coupler Module
5 Standard type with no explosion protection
E Standard type with explosion protection
0 Basic type
1 With ISA Standard G3 option
Operating Voltage:24 V DC
Number of inputchannels:8, isolated channels
Input frequency :0 to 10 kHz
Minimum input pulse width:40 µs
Pull-up resistance:68 kΩ (12 V DC or 24 V DC)
Filter:Filter for eliminating chattering can be set
Data update period:2 ms
PROFIBUS/MPI or PROFINET
Control Voltage: 24 V DC (±15%)
Output Switching Frequency: 1–16 kHz
Isolation Voltage: ≥2.5 kV AC
Operational Temperature: 0°C to +50°C