16 3300 XL 8 mm probe
10 1.0 m (39 in)
03Two plugs,
one 3/4-14 NPT fittingOne 3/4-14 to 1/2-14 NPT SST
reducerOne cable seal grip with grommets
forthe following cable sizes:
1/8 to 3/16 inches
1/4 to 5/16 inches
5/16 to 3/8 inches
02 3/4-14 NPT
02 M30x2 thread
MaximumUnthreadedLength224 mm
MaximumUnthreadedLength8.9 in
MaximumUnthreadedLength250 mm
10 1.0 metre (3.3 feet)
00 No Armor
00 No Approvals
3300 XL 8 mm Probe
3/8-24 UNFthread
without armor
15 1.5 meter (4.9 feet)
02 Miniature coaxial ClickLocconnector, standard cable
05 CSA, ATEX, IECEx Approvals
Order in increments of 0.1 in.
Standard thread configurations:
Maximum case length: 9.6 in.
Minimum case length: 0.8 in.
Example: 2 4 = 2.4 in
Input Channels 32
Galvanic Isolation 1500 VAC RMS or ±1500 VDC
Isolation Technique Optical (in IOM)
DI Power Voltage Range 18 to 30 VDC
ON Sense Voltage/Current 13 VDC (min) or 3 mA (min)
OFF Sense Voltage/Current 5 VDC (max) or 1.2 mA (max)
Input Impedance 4.2
Absolute Delay Across Input Filter and Isolation 5 ms ± 20%
Field Resistance for Guaranteed ON Condition 300 max @ 15 VDC
Output Type 4-20 mA
Output Channels 16
Output Ripple < 100 mV peak-to-peak at
power line frequency, across 250 load
Output Temperature Drift 0.005% of Full Scale/°C
Output Readback Accuracy ±4% of Full Scale
Output Current Linearity ± 0.05% of Full Scale nominal
Resolution ± 0.05% of Full Scale
Calibrated Accuracy ± 0.35% of Full Scale (25oC) including linearity
Directly Settable Output Current Range 0 mA, 2.9 mA to 21.1 mA
Maximum Output Compliant Voltage 16 V
Common Mode Rejection Ratio, dc to 60 Hz 70 dB
Common Mode Voltage, dc to 60 Hz -6 to +5 V peak
A/D Converter Resolution 16 bits
Normal Mode Rejection Ratio, at 60 Hz 19 dB
Normal Mode Filter Response Single-pole RC, -3 dB @ 6.5 Hz
Maximum Normal Mode Input ± 30 Volts
Crosstalk, dc to 60 Hz -60 dB
Input Impedance (voltage inputs) > 10 M Ω powered
Input Scan Rate 50 ms
Input Type: Voltage current
(2-wire or self-powered transmitters)
Input Channels : 16 Channels
Common Mode Voltage, dc to 60 Hz -6 to +5 V peak
A/D Converter Resolution 16 bits
Normal Mode Rejection Ratio, at 60 Hz 19 dB.
Normal Mode Filter Response Single-pole RC, -3 dB @ 6.5 Hz
Maximum Normal Mode Inpu ± 30 Volts
Crosstalk, dc to 60 Hz -60 dB
Input Impedance (voltage inputs) > 10 M Ω powered
Input Scan Rate 50 ms
Power Supply Voltage:24 VDC
Operating Temperature Range:-20°C to +60°C
Communication Interface:RS-485
Input Current:Up to 10 mA
Output Power:150 mA
Humidity Range:
10% to 90% RH (non-condensing)
Power Supply Voltage:24 VDC
Operating Temperature Range:-20°C to +60°C
Communication Interface:RS-485
Input Current:Up to 10 mA
Output Power:150 mA
Humidity Range:
10% to 90% RH (non-condensing)
Power Supply Voltage:24 VDC
Operating Temperature Range:-20°C to +60°C
Communication Interface:RS-485
Input Current:Up to 10 mA
Output Power:150 mA
Humidity Range:
10% to 90% RH (non-condensing)
Power Supply Voltage:24 VDC
Operating Temperature Range:-20°C to +60°C
Communication Interface:RS-485
Input Current:Up to 10 mA
Output Power:150 mA
Humidity Range:
10% to 90% RH (non-condensing)
Input voltage range: 10-30V DC
Output voltage: 24V DC typical
Input: Up to 2mA per channel
Output: Rated for up to 2A per channel
Wiring Capability: typically 16-24 AWG
Operating Temperature: -40°C to +60°C
Humidity Tolerance: Up to 95% non-condensing
Voltage Rating: Up to 250V AC/DC
Current Capacity: Typically up to 10A
Operating Temperature: -40°C to +70°C
Humidity Tolerance:
Up to 95% non-condensing
DC link voltage 510 ... 720 V DC
Electronics power supply 24 V DC -15%/+20%
1 electronics power supply connection
via integrated24 V DC busbars
3 DRIVE-CLiQ sockets
1 safe standstill input (enable pulses)
1 safe motor brake control
1 temperature sensor input
Type: Incremental encoder
Resolution: 360 pulses per revolution
Output: Likely TTL or HTL,
but could be other types like RS422
Supply Voltage: Typically 5V or 24V
Operating Temperature: -20°C to +85°C
Mounting: Shaft or flange mount
Housing: Plastic or metal
Shaft Diameter: Varies depending on the application
MPC60x Class of Microprocessors
16KB/16KB or 32KB/32KB L1 cache
256KB L2 cache
Up to 512MB ECC DRAM On-Board Memory
8MB on-board Flash, 1MB Socketed
Ethernet Transceiver Interface
with 32-Bit PCI Local Bus DMA
8- or 16-bit Fast SCSI-2 Bus Interface
Parallel, Floppy, Keyboard
and Mouse Interfaces
Motherboard (MB)
for IGS Gas Box systems.
Input Voltage: 24V DC
Operating Temperature: 0°C to 60°C (32°F to 140°F)
Storage Temperature: -20°C to 85°C (-4°F to 185°F)
Humidity: Up to 95% RH, non-condensing
Series: VIOP Phase III
Supported Signal Types: 4–20 mA, 0–10 V
Input Voltage: 5V DC or 24V DC
Output Types: 0–10 V, 4–20 mA
Operating Temperature: 0°C to 60°C (32°F to 140°F)
Storage Temperature: -20°C to 85°C (-4°F to 185°F)
Humidity Tolerance: 5% to 95% RH, non-condensing
PCBA VIOP Board
Series: VIOP Phase III Series
Voltage Range: 5V DC or 24V DC
Signal Types: 4–20 mA, 0–10 V
Input range: 0–24V DC
Operating Temperature: 0°C to +60°C (32°F to 140°F)
Storage Temperature: -20°C to +85°C (-4°F to 185°F)
Humidity: 5% to 95% non-condensing
PCBA VIOP Board
Series: VIOP Phase III Series
Voltage Range: 5V DC or 24V DC
Signal Types: 4–20 mA, 0–10 V
Input range: 0–24V DC
Operating Temperature: 0°C to +60°C (32°F to 140°F)
Storage Temperature: -20°C to +85°C (-4°F to 185°F)
Humidity: 5% to 95% non-condensing
PCB ASSY VIOP III
BOARD MODULE CARD
Name: VIOP Phase III Board
Operating Voltage: Typically 5V DC or 24V DC
Accepts signals such as 4–20mA
Current loops or 0–10V DC voltage inputs
Input range: 0–24V DC
Operating Temperature: 0°C to +60°C (32°F to 140°F).
Storage Temperature: -20°C to +85°C (-4°F to 185°F).
Humidity: 5% to 95% non-condensing.
LAM RESEARCH VIOP PHASE
Operating Voltage:
Typically 24V DC or 5V DC
Typical range: 0–10V DC, ±10V DC,
or 4–20mA current loop
Input voltage levels: Typically 0–24V DC
Operating Temperature:
Typically 0°C to +60°C (32°F to 140°F).
Storage Temperature:
-20°C to +85°C (-4°F to 185°F).
Humidity: 5%–95% non-condensing
Inputs :8
Input Type :Single-ended Non-isolated
Resolution :16 bits
Data Format :Configurable
Functional Data Range:15V at 22mA
Module Field-side Power Consumption:7.5 W
Power Dissipation:5.2 W
Thermal Dissipation:17.75 BTU/hour
Step Response:4 ms
Number of Input Channels:
Typically 4, 8, or 16 channels
Voltage: 0–10V DC or ±10V DC
Current:4–20mA or 0–20mA
Resolution: 12-bit, 14-bit, or 16-bit resolution
Operates at 24V DC
Operating Temperature:
0°C to 60°C (32°F to 140°F).
Storage Temperature:
-25°C to 85°C (-13°F to 185°F).
Humidity: 5% to 95% relative humidity
4 safety inputs for 4 to 20 mA signals
forming 2 logic safety channels
Optional encoder supply via the module
4 safety inputs for temperature measurement (Pt100)
forming 2 logic safety channels
2 safety inputs for strain gauge signals
forming one logic safety channel
AC input: 100-240V AC, 50/60 Hz
DC input: accepts 24V DC
Operating Temperature:
0°C to 60°C (32°F to 140°F)
Storage Temperature:
-20°C and 85°C (-4°F to 185°F)
Humidity: 5% to 95% RH non-condensing
Voltage Rating: Typically
24V DC or 110V-240V AC
Operating Temperature:
Typically 0 to 70°C (32°F to 158°F)
Storage Temperature:
Generally -20°C to 70°C (-4°F to 158°F)
Humidity: Designed for
environments with 30-85% RH
Power Supply:DC 24V
Digital Input: Typically 24V DC
Operating Temperature:
Typically 0 to 50°C (32°F to 122°F)
Storage Temperature:
Typically -20°C to 70°C (-4°F to 158°F)
Humidity: 30% to 85% RH, non-condensing
System Security via Password
Color Touch Screen with Full Screen Color Graphics
4 LEDs: Power / Network / COM 2 / COM 1
Modbus Master/Slave Configurations
Key Process Variable Display Capability
3 Display Operational Modes:
Local, Switchable or System