Two-wire Transducer
06 0 ±100, 10 Hz (600 cpm)
05 Terminal block top mount (nocable)
10 Circular; M10X1 stud
00 No Approvals
3300 NSv Extension Cable
3300 NSv Extension Cable
040 4.0 meters (13.1 feet)
02 With stainless steel armor,without FEP jacket
00 Not Required
Measuring Interface Unit
Supply Voltage: 24V DC ±10%
Power Consumption: <15W typical
Voltage ranges: ±10V
Current ranges: 0-20mA
Resolution: 16-bit (minimum)
Sampling Rate: Up to 1kS/s per channel
Accuracy: ±0.1% of full scale
Isolation: 1500V AC
SPB Circuit Board
Input Voltage: Typically 24V DC
Operating Voltage Range: ±15V DC
Current Consumption:<500mA
Isolation Voltage: 1000V AC
Fiber optic or optocoupled signals
Digital I/O (for control signals)
Printed Circuit Board
Logic Side: 5V DC
Isolated Side: 15V DC
Current Rating: Typically <1A
Reinforced isolation:≥2500V AC
High-speed digital signals
Analog inputs:0-10V, 4-20mA
Power Supply Module
Input Voltage:230V AC
Range: Typically ±15%
Output Voltage:+24V DC
Auxiliary Outputs: ±15V DC
Efficiency: >85%
Isolation: 2500V AC
Terminal blocks for AC input and DC output
Multi-pin headers for control signals
3300 XL 8 mm Proximity Probes
330103 3300 XL 8 mm Probe
M10 x 1 thread,without armor
Minimum unthreaded length: 40 mm
Minimum case length: 130 mm
10 1.0 meter (3.3 feet)
02 Miniature coaxial ClickLocconnector
standard cable
00 Not required
3300 XL 8 mm Reverse Mount Probes
3300 XL 8 mm Reverse Mount Probes
330105-02-12-CC-DD-EE3/8-24 UNF threads
10 1.0 meter (3.3 feet)
02 Miniature ClickLoc coaxialconnector
00 Not required
3300 XL Standard Extension Cable
3300 XL Standard Extension Cable
085 8.5 meters (27.9 feet)
13 Armored FluidLoc cable
withconnector protector
05 CSA, ATEX, IECEx Approvals
3300 XL 8 mm Proximity Probes
330102 3300 XL 8 mm Probe
3/8-24 UNFthread, with armor
Minimum unthreaded length: 0.0 in
Minimum case length: 4.8 in
05 0.5 meter (1.6 feet)
02 Miniature coaxial ClickLocconnector
standard cable
00 Not required
3300 XL 25 mm Proximity Probe
02 M30x2 thread
MinimumUnthreadedLength 0 mm
Example 050 = 50 mm
90 9.0 metres (29.5 feet)
00 No Armor
05 Multiple Approvals
Servo Control Module
Series: Mark VIe
Microprocessor: Intel Celeron 650 MHz
Number of inputs: 8
Power supply voltage: 28 V dc
Memory: 128 MB SDRAM
Number of outputs: 2
LVDT Excitation Output: 3.2 kHz
Programming: Boolean
Product Type: Simplex Servo Control I/O Module
Copyright Notice © 2004-2024 amikong.com All rights reserved
Disclaimer: We are not an authorized distributor or distributor of the product manufacturer of this website, The product may have older date codes or be an older series than that available direct from the factory or authorized dealers. Because our company is not an authorized distributor of this product, the Original Manufacturer’s warranty does not apply.While many DCS PLC products will have firmware already installed, Our company makes no representation as to whether a DSC PLC product will or will not have firmware and, if it does have firmware, whether the firmware is the revision level that you need for your application. Our company also makes no representations as to your ability or right to download or otherwise obtain firmware for the product from our company, its distributors, or any other source. Our company also makes no representations as to your right to install any such firmware on the product. Our company will not obtain or supply firmware on your behalf. It is your obligation to comply with the terms of any End-User License Agreement or similar document related to obtaining or installing firmware.