Robot spray accessory controller
Supply Voltage: 24V DC (±10%), 5A max.
Atomization air pressure control
Fluid flow regulation (via PWM or analog valve)
HV electrostatic control (up to 100 kV)
Solvent purge management
Diagnostic monitoring (clogs, pressure faults)
Power Consumption: 120W (peak)
Panel unit
Module Slots: 8 slots for S800 I/O modules
Orientation: Vertical
Bottom/top gland openings
(M20/M25 cable glands)
Knockouts for field wiring
Binary In/Out Module
Input Impedance: 3-5 kΩ (High Range)
Maximum Continuous Voltage: 300V DC.
Maximum Surge Voltage: 1 kV, 1.2/50 µs waveform.
Operating Time: < 5 ms.
Release Time: < 5 ms.
I/O TERMINAL BOARD
System Power: 24 V DC
Field Power:24V DC
Data Transfer Rate:
up to 12 Mbps for PROFIBUS DP
Binary Control Module
Range: Typically 20.4 V DC
Series: 83SR Safety Relay System
Channel-to-Backplane/Logic: Yes
Isolation Voltage: Typically 250V AC
Safety Certification: TÜV Rheinland certified
FTA interconnection cable
System Interconnection Cable For Chassis IO
FS-SICC-0001/Lx (where × = length)
20 × AWG 22 (= 0.34 mm²) double shielded
9.93 mm / 0.39 in
3 = 3m

Copyright Notice © 2004-2024 amikong.com All rights reserved
Disclaimer: We are not an authorized distributor or distributor of the product manufacturer of this website, The product may have older date codes or be an older series than that available direct from the factory or authorized dealers. Because our company is not an authorized distributor of this product, the Original Manufacturer’s warranty does not apply.While many DCS PLC products will have firmware already installed, Our company makes no representation as to whether a DSC PLC product will or will not have firmware and, if it does have firmware, whether the firmware is the revision level that you need for your application. Our company also makes no representations as to your ability or right to download or otherwise obtain firmware for the product from our company, its distributors, or any other source. Our company also makes no representations as to your right to install any such firmware on the product. Our company will not obtain or supply firmware on your behalf. It is your obligation to comply with the terms of any End-User License Agreement or similar document related to obtaining or installing firmware.